Plan Review Details - Permit 20111059
Plan Review Stops For Permit 20111059
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2020-12-21 Cont ID  
Sent By ccole Date 2020-12-21 Time 08:03 Rev Time 0.00
Received By ccole Date 2020-12-21 Time 07:16 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2020-12-14 Cont ID  
Sent By ccole Date 2020-12-14 Time 18:07 Rev Time 0.00
Received By ccole Date 2020-12-14 Time 16:32 Sent To  
Notes
2020-12-14 18:08:213RD REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20111059
 12/14/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: THE EHD 18 CSST PIPING TO THE 58,200 BTUH
 COOKTOP IS UNDERSIZED PER TABLE 402.4(15) FBC FG.
 EHD-23 IS REQUIRED BASED ON SECTIONS 402.4.1 AND
 402.4.2. THE PIPE RUN FROM THE LOW PRESSURE REGULATOR
 TO THE COOK TOP IS 77 FT. PLEASE CORRECT THE RISER.
  
 2) THE PRINTED NAME AND SIGNATURE OF THE FL. LICENSED
 GAS CONTRACTOR JOSEPH PETRILLO SHALL BE ON THE GAS
 RISER DRAWING IN COMPLIANCE WITH SECTION 107.2.1 WPB,
 AND FLORIDA STATUTES 471.003(2)(H) & 471.025. THE
 DRAWING APPEARS TO BEAR THE SIGNATURE AND SEAL OF THE
 NOTARY PUBLIC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-12-02 Cont ID  
Sent By ccole Date 2020-12-02 Time 17:14 Rev Time 0.00
Received By ccole Date 2020-12-02 Time 13:17 Sent To  
Notes
2020-12-02 17:14:172ND REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20111059
 12/2/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A DESCRIPTION OF WORK ON THE PERMIT
 APPLICATION AND A VALUE FOR GAS PIPING AND APPLIANCE
 INSTALLATIONS- SECTIONS 105.1, 107.1, AND 109.3 WPB.
 THE TOTAL VALUE OF THE PROJECT SHALL INCLUDE LABOR,
 MATERIAL, EQUIPMENT AND APPLIANCES. SUBMIT A COPY OF
 THE SIGNED CONTRACT AND/OR ESTIMATES AND INVOICES TO
 VERIFY THE PROJECT COSTS. COSTS ASSOCIATED WITH THE GAS
 PIPING AND APPLIANCE INSTALLATIONS THAT WERE ACCOUNTED
 FOR UNDER THE MASTER PERMIT- 20010400 CAN BE EXCLUDED,
 HOWEVER DOCUMENTATION OF THOSE COSTS MUST BE PROVIDED.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 TANKLESS WATER HEATER, COOKTOP, AND THE DRYER. SUBMIT
 ONLY THE SHEETS THAT SHOW BTUH CAPACITIES AND INPUT
 PRESSURES. PLEASE NOTE THAT PERMITS FOR THE POOL AND
 GENERATOR HAVE NOT BEEN SUBMITTED. CLARIFY HOW THE BTUH
 LOADS FOR THE POOL HEATER AND GENERATOR WERE
 DETERMINED- SECTION G2408.1 FBC RES.
  
 3) GAS RISER:
  
 A) INDICATE A NEW OR EXISTING GAS METER AND SHOW THE
 TYPE AND SIZE OF MAIN SUPPLY RISER AT THE METER-
 G2412.8 RES.
  
 B) THE PIPE SIZING TABLES 402.4(13) AND 402.4(20) ARE
 FOR LOW PRESSURE SEMIRIGID COPPER TUBING AND PE. THERE
 IS NO COPPER SHOWN ON THE RISER AND THE PE PIPING IS 2
 PSI. PLEASE PROVIDE THE CORRECT SIZING TABLES FOR ALL
 TYPES OF PIPING RELATIVE TO THE GAS PRESSURES- REFER TO
 TABLES G2413.4(1)- G2413.4(8) FBC RES. PLEASE NOTE THAT
 TABLES 402.4(1) AND 402.4(3) ARE BOTH LOW PRESSURE
 TABLES FOR SCHEDULE 40 GALVANIZED. WHICH TABLE IS
 APPLICABLE TO THE PROJECT.
  
 C) SHOW THE TYPES AND SIZES OF RISER PIPES SUPPLYING
 THE TWH, POOL HEATER, AND GENERATOR- SECTION G2413.3.
  
 D) SHOW GAS-TIGHT CAPS FOR THE SUPPLY LINES TO THE
 FUTURE POOL HEATER AND GENERATOR- G2415.15 FBC RES.
  
 E) SHOW THE OUTLET PRESSURE AT THE REGULATOR SHOWN ON
 THE 1 IN. GALV. RISER- G2421.2.
  
 F) SHOW THE REQUIRED PIPE UNIONS WITHIN 1 FT. OF EITHER
 SIDE OF THE REGULATOR- SECTION G2421.2(7).
  
 G) SHOW THE EHD'S OF THE 1 IN. AND 1/2 IN. CSST-
 SECTION G2413.4 AND INDICATE THE PIPE SIZING TABLE
 USED. A COMPLETE REVIEW OF THE SIZING CANNOT BE
 ACCOMPLISHED AT THIS TIME.
  
 H) SHOW THE TYPE AND SIZE OF UNDERGROUND GAS PIPING TO
 THE COOKTOP- SECTION G2413.3.
  
 I) SHOW THE TYPE AND SIZE OF PIPE SLEEVE- SECTIONS
 G2415.14 AND SHOW HOW IT WILL BE PROTECTED FROM
 CORROSION- SECTION G2415.11.
  
 J) SHOW HOW THE SLEEVE VENT WILL BE INSTALLED TO
 PREVENT THE ENTRANCE OF INSECTS- SECTION G2415.14.1.
  
 3) SUBMIT MARKED UP OR HIGHLIGHTED SPECS SHOWING THE
 SELECTED MODELS, THE MAX INLET AND OUTLET SIZES AND
 PRESSURES AND ORIFICE SIZES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2020-12-21 Time   Rev Time 0.00
Received By lmarchan Date 2020-12-16 Time 11:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-12-14 Time   Rev Time 0.00
Received By ccarvaja Date 2020-12-10 Time 16:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2020-12-02 Time   Rev Time 0.00
Received By ccarvaja Date 2020-11-24 Time 15:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2020-12-21 Cont ID  
Sent By ccole Date 2020-12-21 Time 08:03 Rev Time 0.00
Received By ccole Date 2020-12-21 Time 07:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2020-12-14 Cont ID  
Sent By ccole Date 2020-12-14 Time 17:12 Rev Time 0.00
Received By ccole Date 2020-12-14 Time 16:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2020-12-02 Cont ID  
Sent By ccole Date 2020-12-02 Time 13:28 Rev Time 0.00
Received By ccole Date 2020-12-02 Time 13:28 Sent To  
Notes
2020-12-02 13:31:06PLUMBING REVIEW AND PERMIT NOT REQUIRED UNDER THIS
 PERMIT. A PLUMBING SUB-PERMIT UNDER THE MASTER PERMIT-
 20010400 IS REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-12-21 Cont ID  
Sent By ccole Date 2020-12-21 Time 08:03 Rev Time 0.00
Received By ccole Date 2020-12-21 Time 07:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-12-14 Cont ID  
Sent By ccole Date 2020-12-14 Time 18:08 Rev Time 0.00
Received By ccole Date 2020-12-14 Time 16:32 Sent To  
Notes
2020-12-14 18:09:41SIGNATURE REVIEW
 12/14/2020
  
 THE PRINTED NAME AND SIGNATURE OF THE FL. LICENSED GAS
 CONTRACTOR JOSEPH PETRILLO SHALL BE ON THE GAS RISER
 DRAWING IN COMPLIANCE WITH SECTION 107.2.1 WPB, AND
 FLORIDA STATUTES 471.003(2)(H) & 471.025. THE DRAWING
 APPEARS TO BEAR THE SIGNATURE AND SEAL OF THE NOTARY
 PUBLIC.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-12-02 Cont ID  
Sent By ccole Date 2020-12-02 Time 17:17 Rev Time 0.00
Received By ccole Date 2020-12-02 Time 13:17 Sent To  
Notes
2020-12-02 17:20:13SIGNATURE REVIEW
 12/2/2020
  
 THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING
 SHALL PROVIDE HIS SIGNATURE ON IT- SECTION 107.2.1 WPB,
 AND FLORIDA STATUTES 471.003(2)(H) & 471.025.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved