Plan Review Details - Permit 20110975
| Plan Review Stops For Permit 20110975 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-03 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-03 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2020-12-03 08:25:04 | 12/03/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-25 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-25 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2020-11-25 14:04:18 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20110975 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE PIPE MATERIAL USED. PLEASE SHOW | | | THE SYSTEM PRESSURE. PLEASE SHOW IF THIS IS AN OUTDOOR | | | OR INDOOR INSTALLATION. FBC 107.3.5.1.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-03 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-02 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-30 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-20 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-03 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-03 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2020-12-03 08:26:54 | 12/03/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-30 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-30 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-30 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2020-11-30 07:50:49 | 11/30/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. GAS UNITS REQUIRE CONDENSATE AND THEY NEED TO BE 1' | | | AWAY FROM STRUCTURE PER THE 2017 FBC SEC R318.5. | | | | | | 2. PLEASE SUBMIT A HOUSE PLAN SHOWING THE LOCATION OF | | | THE TANK-LESS WATER HEATER AND THE LOCATION AND | | | DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN RELATION | | | TO THE WATER HEATER. THE LOCATION OF THE WATER HEATER | | | SHALL COMPLY WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. THE HOUSE PLAN CAN BE HAND-DRAWN PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 3. PIPES NOT IN CONDITION SPACE AND OR OUTSIDE NEED TO | | | BE INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. | | | RE 403.5.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-25 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-25 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
|