| Plan Review Stops For Permit 20110970 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-01-21 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-01-21 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2020-12-16 16:51:59 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: STRUCTURAL PLAN SHEET S-2 AND S-3 ARE MISSING | | | FROM THE SUBMITTAL. A COMPLETE REVIEW CANNOT BE | | | PERFORMED AT THIS TIME. | | | | | | 1. PROVIDE A ROOF FRAMING PLAN. INCLUDE TRUSS LAYOUT; | | | WIND DESIGN PRESSURES; FASTENER SPECIFICATIONS AND | | | SPACING FOR ZONES 1, 2 & 3. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 2. PROVIDE EXTERIOR WALL DETAIL. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. PROVIDE SITE WIND DESIGN LOADS PER FBC 107.3.5.3 ? | | | PROVIDE WIND DESIGN LOADS/DESIGN PRESSURES PURSUANT TO | | | FBC-R301.2. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | 4. PROVIDE ROUGH OPENINGS AND WIND DESIGN PRESSURES FOR | | | EACH WINDOW AND EXTERIOR DOOR OPENING. | | | YOU MAY INCLUDE THESE IN THE WINDOW AND DOOR SCHEDULE | | | OR PLACE THEM NEXT TO EACH OPENING ON PLAN. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-01-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-01-11 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-01-11 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2020-12-16 17:02:31 | PLAN REVIEW / ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE UPDATED LOAD CALC'S. | | | PROVIDE ACCURATE LOAD CALCULATIONS INCLUDING ALL LOADS | | | FOR THE SERVICE AS WELL AS THE LOAD CALCULATIONS FOR | | | THE INDIVIDUAL PANELS. NEC 220; FBC RE 3602.2. | | | | | | 2. PROVIDE NEW PANEL SCHEDULE. | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 3. PROVIDE ILLUMINATION AT ENTRY/EGRESS DOOR. | | | FBC 1006.1.1 PER FBC-R, T-E3403 | | | ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND | | | STRUCTURE. | | | | | | 4. HIGH EFFICACY LAMPS | | | PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". | | | | | | A NOTE ON THE PLAN WILL SUFFICE. FBC EC R404.1 | | | | | | 5. PROVIDE EQUIPMENT SERVICE OUTLET FOR C/U. | | | E3901.12 HVAC OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE | | | LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM) | | | OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED | | | TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING | | | MEANS. (210.63) | | | | | | NOTICE: AFCI OUTLETS | | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. PROVIDE COMPLIANCE. NEC | | | 210.12; FBC RE E3902.16 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-01-21 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-08 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-03 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-01-29 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-21 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2021-01-29 10:28:45 | RECEIPT MU-2021-003879 - $1945.04 - PAID | | 2021-01-21 13:49:38 | 1/21/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2020-12-16 16:35:35 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-12 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-12 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-14 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-14 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2020-12-14 09:53:39 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20110970 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IS THE NEW MECHANICAL SYSTEM CONDITIONING THE ENTIRE | | | RESIDENCE? THERE IS NO INDICATION THAT ANOTHER SYSTEM | | | IS IN USE NOW. FBC 107.2.1 | | | | | | 2) PLEASE SHOW THE DRYER DUCT AND EXHAUST TERMINATION. | | | FBC RES M1502.3 | | | | | | 3) PLEASE SHOW THE CONDENSATION PIPING AND DRAINAGE | | | LOCATION. FBC RES M1411.3 | | | | | | 4) PLEASE SHOW HOW THE CONDENSING UNIT WILL BE | | | ANCHORED. FBC RES M1307.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-12-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-04 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-04 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2020-12-16 13:40:40 | PROVISO: A SEPERATE ROOFING PERMIT IS REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-25 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-01-25 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2021-01-25 09:44:03 | DRAWINGS S-1, S-2 AND S-3 WITH ENGINEER'S ORIGINAL SEAL | | | AND SIGNATURE MATCHES APPROVED ONES. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-01-21 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-01-21 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2021-01-21 08:29:38 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: STRUCTURAL PLAN PAGES ONLY. | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-16 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-16 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2020-12-16 11:19:19 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR | | | DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL | | | SIGNATURE. | | | | | | 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-12-14 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-12-14 |
Time |
|
Sent To |
I |
|
| Notes |
|
|