Plan Review Details - Permit 20110703
Plan Review Stops For Permit 20110703
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2021-01-25 Cont ID  
Sent By cpuell Date 2021-01-25 Time 15:08 Rev Time 0.00
Received By cpuell Date 2021-01-25 Time 15:08 Sent To  
Notes
2021-01-25 15:09:35142 SUITE CREATED FOR AREA, SPLIT FROM 140

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2021-01-15 Cont ID  
Sent By cpuell Date 2021-01-15 Time 09:12 Rev Time 0.00
Received By cpuell Date 2021-01-15 Time 09:12 Sent To  
Notes
2021-01-15 09:14:23SUITE 142E IS NOT CURRENTLY A LEGAL SUITE NUBER, PLEASE
 PROVIDE A FLOOR PLAN FOR THE ENTIRE FLOOR INDICATING
 WHERE THE MAIN ENTRANCE IS TO [email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-11-21 Cont ID  
Sent By cpuell Date 2020-11-21 Time 10:04 Rev Time 0.00
Received By cpuell Date 2021-01-15 Time 09:12 Sent To  
Notes
2020-11-21 10:04:52PLEASE INDICATE WHICH EXISTING TENANT SPACE YOU WILL
 REMODELING. DOES THIS SUITE HAVE A SUITE NUMBER. PLEASE
 EMAIL RESPONSES TO [email protected]

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2021-02-16 Cont ID  
Sent By shill Date 2021-02-16 Time 12:42 Rev Time 0.00
Received By shill Date 2021-02-16 Time 12:42 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2021-02-02 Cont ID  
Sent By jwitmer Date 2021-02-02 Time 14:15 Rev Time 0.00
Received By jwitmer Date 2021-02-02 Time 13:14 Sent To  
Notes
2021-02-02 14:15:01TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2021-01-18 Cont ID  
Sent By jwitmer Date 2021-01-18 Time 10:28 Rev Time 0.00
Received By jwitmer Date 2021-01-18 Time 09:26 Sent To  
Notes
2021-01-18 10:28:43TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2020-11-24 Cont ID  
Sent By jwitmer Date 2020-11-24 Time 15:06 Rev Time 0.00
Received By jwitmer Date 2020-11-24 Time 15:02 Sent To  
Notes
2020-11-24 15:05:43TO THE BUILDING CONTRACTOR:
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN PDF
 FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE
 THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-02-02 Cont ID  
Sent By jwitmer Date 2021-02-02 Time 14:15 Rev Time 0.00
Received By jwitmer Date 2021-02-02 Time 13:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-01-18 Cont ID  
Sent By jwitmer Date 2021-01-18 Time 10:30 Rev Time 0.00
Received By jwitmer Date 2021-01-18 Time 09:25 Sent To  
Notes
2021-01-18 10:30:54WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20110703
 ADD: 777 S. FLAGLER DR. / 1ST FLOOR/ SUITE???
 CONT: MENEMSHA DEVELOPMENT GROUP
 TEL: 781-666-4973
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. JAN. 18TH/ 2021
 ACTION: DENIED
  
 1) COMPLIED.
  
 2 )2ND REQUEST. MISSING INFORMATION. SHEET A00.33
 INDICATES THAT IS WHERE THE CODE REVIEW INFORMATION IS
 FOUND BUT THE SAME DOOR SCHEDULE IS FOUND AS ON A0.30.
 SHEET A00.33 STILL HAS THE DATE 11/20/2020, NOT
 UPDATED.
 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
  
 MISSING CODE DATA:
 OCCUPANCY GROUP
 MINIMUM TYPE OF CONSTRUCTION
 FIRE RESISTANCE SEPARATION
 LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE
 FOLLOWING:
 CODE DATA/ BUILDING DATA
 OCCUPANT LOAD AND EGRESS CAPACITIES
 GROSS OR NET
 MEANS OF EGRESS EXIT ACCESS
 EXIT
 EXIT DISCHARGE
  
 3)COMPLIED.
  
 4) SEMI-COMPLIED. SHEET A00.30 THE DOOR SCHEDULE DOOR
 TYPE C NOW SHOWS THE WIND DESIGN CRITERIA. THE V-ULT
 WIND SPEED IS INDICATED AS 160 VULT. PLEASE REFER TO
 THE 2017 FBC-BUILDING CODE TABLE FIGURE 1609.3(1) THE
 CORRECT WIND SPEED FOR A RISK CATEGORY TYPE II BUILDING
 IS 170 VULT OR 132 VASD. THE WIND EXPOSURE IS CORRECT
 AS EXPOSURE D.
  
 1ST ROUND OF COMMENTS. SHEET A02.01 SHOW A NEW
 (REPLACEMENT) EXTERIOR DOOR # 101 AND SIDE LIGHTS. THE
 PLANS DO NOT PROVIDE THE WIND DESIGN DATA. 2017 FBC-B
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 4.2. RISK CATEGORY.
  
 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 4.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 5-6) COMPLIED.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-24 Cont ID  
Sent By jwitmer Date 2020-11-24 Time 16:37 Rev Time 0.00
Received By jwitmer Date 2020-11-24 Time 15:02 Sent To  
Notes
2020-11-24 16:37:13WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20110703
 ADD: 777 S. FLAGLER DR. / 1ST FLOOR/ SUITE???
 CONT: MENEMSHA DEVELOPMENT GROUP
 TEL: 781-666-4973
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV.24TH./ 2020
 ACTION: DENIED
  
 1) NEITHER THE PERMIT APPLICATION NOR TITLEBLOCK OF THE
 PLANS PROVIDE THE SUITE NUMBER WHERE WORK IS TO BE
 PERFORMED FOR THIS PERMIT. 2017 FLORIDA BUILDING CODE W
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED.
  
 2) MISSING INFORMATION. SHEET A00.30 INDICATES THERE IS
 DOOR SCHEDULES & DETAILS WHICH THERE IS BUT WHEN YOU
 REVIEW SHEET A00.33 CODE REVIEW YOU HAVE THE SAME SHEET
 LOADED FOR DOOR SCHEDULE & DETAILS.
 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
  
 MISSING CODE DATA:
 FLOOD HAZARD AREAS, FLOOD ZONES, AND DESIGN FLOOD
 ELEVATIONS
 PROPOSED FLOOD ELEVATION CERTIFICATE FOR STRUCTURES IN
 A SPECIFIC FLOOD HAZARD AREA
 OCCUPANCY GROUP
 MINIMUM TYPE OF CONSTRUCTION
 FIRE RESISTANCE SEPARATION
 LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE
 FOLLOWING:
 CODE DATA/ BUILDING DATA
 OCCUPANT LOAD AND EGRESS CAPACITIES
 GROSS OR NET
 MEANS OF EGRESS EXIT ACCESS
 EXIT
 EXIT DISCHARGE
  
 3) SHEET A02.01:
 3A) THE CUSTOMER PANTRY 112 & COLLEAGUE PANTRY 115, THE
 FLOOR PLAN DOES NOT SHOW THE REQUIRED FRONTAL CLEAR
 FLOOR SPACE FOR THE SINK. SEE 2017 FBC-ACCESS. CODE
 SECTION 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED, SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED
 CLEAR FLOOR SPACE ON THE FLOOR PLAN.
  
 3B) THE FLOOR PLAN SHOWS A UNISEX RESTROOM # 113 AND
 DETAILS ON A11.03 DETAIL 9. DETAIL # 9 SHOWS THE WALL
 COVERING TYPE AS WC-5. THE FINISH SCHEDULE STATES WALL
 COVERING. WALL COVERINGS AND PAINT ARE NOT CONSIDERED A
 HARD-NON-ABSORBENT SURFACE.
 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT
 IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION. IN
 RESTROOMS EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH
 HARD, NON-ABSORBENT SURFACE.
 WALLS & PARTITIONS WITHIN 2 FEET OF SERVICE SINKS,
 URINALS, AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4
 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIAL USED IN SUCH WALLS SHALL BE OF A TYPE THAT
 IS NOT ADVERSELY AFFECTED BY MOISTURE.
 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET WALLS
 SHALL COMPLY WITH 1210.2.
 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS AND
 PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH
 SECTIONS 1210.1 THROUGH 1210.4.
  
 4) SHEET A02.01 SHOW A NEW (REPLACEMENT) EXTERIOR DOOR
 # 101 AND SIDE LIGHTS. THE PLANS DO NOT PROVIDE THE
 WIND DESIGN DATA. 2017 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 4.2. RISK CATEGORY.
  
 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 4.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 5) SUBMITTED NOA 16-1213.02 OLDCASTLE BUILDING
 ENVELOPE: SERIES MSD- 375 & WSD-500 OUTSWING GLAZED
 ALUMINUM ENTRANCE DOORS W/WO TRANSOM. PLEASE REVIEW
 CAREFULLY THIS DOOR SYSTEMS IS FOR A DOUBLE DOOR SYSTEM
 OR A SINGLE DOOR AND ONE SIDELIGHT ROUGHLY A 8 FOOT BY
 8 FOOT SYSTEM. IDENTIFY GLAZING/ MULLIONS AND PANIC
 HARDWARE. PLEASE IDENTIFY ON THE PRODUCT APPROVAL
 BEFORE SUBMITTING TO DESIGNER OF RECORD AND BEFORE
 SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS
 WITH GLAZING, PLEASE IDENTIFY THE OPENING WIDTH &
 HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH IF
 UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED,
 ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING
 SIZE. 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND
 DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
 MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING
 SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE
 CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN
 THE TESTS.
  
 6) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By jleahy Date 2021-01-19 Time 16:54 Rev Time 0.00
Received By jleahy Date 2021-01-19 Time 16:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-12-02 Cont ID  
Sent By jleahy Date 2020-12-02 Time 07:47 Rev Time 0.00
Received By jleahy Date 2020-12-02 Time 07:19 Sent To  
Notes
2021-01-18 10:26:17WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20110703
 ADD: 777 S. FLAGLER DR. / 1ST FLOOR/ SUITE???
 CONT: MENEMSHA DEVELOPMENT GROUP
 TEL: 781-666-4973
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. JAN. 18TH/ 2021
 ACTION: DENIED
  
 1) COMPLIED.
  
 2 )2ND REQUEST. MISSING INFORMATION. SHEET A00.33
 INDICATES THAT IS WHERE THE CODE REVIEW INFORMATION IS
 FOUND BUT THE SAME DOOR SCHEDULE IS FOUND AS ON A0.30.
 SHEET A00.33 CODE REVIEW SHOWS A DATE 11/20/2020, NOT
 UPDATED.
 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
  
 MISSING CODE DATA:
 OCCUPANCY GROUP
 MINIMUM TYPE OF CONSTRUCTION
 FIRE RESISTANCE SEPARATION
 LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE
 FOLLOWING:
 CODE DATA/ BUILDING DATA
 OCCUPANT LOAD AND EGRESS CAPACITIES
 GROSS OR NET
 MEANS OF EGRESS EXIT ACCESS
 EXIT
 EXIT DISCHARGE
  
 3)COMPLIED.
  
 4) SEMI-COMPLIED. SHEET A00.30 THE DOOR SCHEDULE DOOR
 TYPE C NOW SHOWS THE WIND DESIGN CRITERIA. THE V-ULT
 WIND SPEED IS INDICATED AS 160 VULT. PLEASE REFER TO
 THE 2017 FBC-BUILDING CODE TABLE FIGURE 1609.3(1) THE
 CORRECT WIND SPEED FOR A RISK CATEGORY TYPE II BUILDING
 IS 170 VULT OR 132 VASD. THE WIND EXPOSURE IS CORRECT
 AS EXPOSURE D.
  
 1ST ROUND OF COMMENTS. SHEET A02.01 SHOW A NEW
 (REPLACEMENT) EXTERIOR DOOR # 101 AND SIDE LIGHTS. THE
 PLANS DO NOT PROVIDE THE WIND DESIGN DATA. 2017 FBC-B
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 4.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 4.2. RISK CATEGORY.
  
 4.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 4.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 4.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 4.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 5-6) COMPLIED.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-01-19 Cont ID  
Sent By jleahy Date 2021-01-19 Time 16:54 Rev Time 0.00
Received By jleahy Date 2021-01-19 Time 16:54 Sent To  
Notes
2021-01-19 16:55:13VOICE AND DATA CCTV

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By pleduc Date 2021-01-19 Time   Rev Time 0.00
Received By pleduc Date 2021-01-19 Time 11:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-11-25 Cont ID  
Sent By pleduc Date 2020-11-25 Time   Rev Time 0.00
Received By pleduc Date 2020-11-24 Time 15:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-02-16 Cont ID  
Sent By shill Date 2021-02-16 Time 12:45 Rev Time 0.00
Received By shill Date 2021-01-29 Time 06:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-20 Cont ID  
Sent By lmarchan Date 2021-01-20 Time 17:03 Rev Time 0.00
Received By lmarchan Date 2021-01-14 Time 08:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-28 Cont ID  
Sent By lmarchan Date 2020-12-28 Time 14:40 Rev Time 0.00
Received By lmarchan Date 2020-11-20 Time 16:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 06:13 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 06:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-27 Cont ID  
Sent By medwards Date 2020-11-27 Time 10:06 Rev Time 0.00
Received By medwards Date 2020-11-27 Time 10:03 Sent To  
Notes
2020-11-27 10:07:28PLEASE PROVIDE SUITE NUMBER OF PROJECT. FBC 107.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2021-02-02 Cont ID  
Sent By ccole Date 2021-02-02 Time 12:35 Rev Time 0.00
Received By ccole Date 2021-02-02 Time 07:08 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2021-01-19 Cont ID  
Sent By ccole Date 2021-01-19 Time 14:11 Rev Time 0.00
Received By ccole Date 2021-01-19 Time 10:42 Sent To  
Notes
2021-01-19 14:11:222ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20110703
 1/19/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 THE REQUESTED COMMENT RESPONSE NARRATIVE WAS NOT
 PROVIDED BY THE ARCHITECT.
  
 1) COMMENT #1 FROM THE 1ST REVIEW FAILED- 2ND REQUEST.
 SHEET P00.01: PROVIDE PLUMBING FIXTURE CALCULATIONS AND
 A SCHEDULE SHOWING THE REQUIRED AND PROVIDED FIXTURES
 IN COMPLIANCE WITH TABLE 403.3 FBC P. PLEASE NOTE THAT
 DRINKING FOUNTAINS AND A SERVICE SINK ARE REQUIRED
 FIXTURES FOR BUSINESS OCCUPANCIES. NO RESPONSE OR
 CORRECTED PLANS PROVIDED. PLEASE NOTE THAT A REVISED
 P00.01 WAS NOT UPLOADED- SHEET FP00.01 WAS UPLOADED IN
 PLACE.
  
 2) SHEET P01.02 DOMESTIC WATER PLAN WAS NOT UPLOADED-
 CORRECTED SHEET P01.01 WAS UPLOADED IN PLACE.
  
 3) NEW PLAN SHEET A801: IT APPEARS IN RESPONSE TO
 COMMENT #7 FROM THE 1ST REVIEW, AN ENLARGED RESTROOM
 PLAN HAS BEEN PROVIDED, HOWEVER THE PLAN HAS NO ROOM
 DIMENSIONS, AND DOES NOT PROVIDE THE DIMENSIONS OF THE
 CLEAR FLOOR SPACES FOR THE WATER CLOSET AND LAVATORY-
 SECTIONS 604.3 & 606.2 FBC ACC. PLEASE CORRECT THE
 PLAN.
  
 4) A801: THE RESTROOM DOOR SHALL NOT SWING INTO THE
 CLEAR FLOOR SPACE FOR THE LAVATORY- SECTION 603.2.3 FBC
 ACC.
  
 5) NEW PLAN SHEET P01.03: THE 3/8 IN. HW LINE FROM THE
 WATER HEATER APPEARS TO BE EXCEEDING THE MAXIMUM 3 FT.
 ALLOWABLE PIPING LENGTH PER TABLE C404.5.1 FBC EC.
  
 6) COMMENT #7H FROM THE 1ST REVIEW- FAILED. AS NOTED IN
 COMMENT #1 DRINKING FOUNTAINS ARE REQUIRED FIXTURES AND
 SHALL BE ACCESSIBLE IN ACCORDANCE WITH SECTIONS 211.2 &
 602.1- 602.6 FBC ACC. PROVIDE DRAWINGS AND DETAILS
 SHOWING: A) THE 30 X 48 IN. CLEAR FLOOR SPACE FOR A
 FORWARD APPROACH TO THE WHEELCHAIR ACCESSIBLE DRINKING
 FOUNTAIN- SECTION 602.2 FBC ACC. B) KNEE AND TOE
 CLEARANCES, SPOUT HEIGHTS, SPOUT LOCATIONS- SECTIONS
 306, 307, & 602.2. C) COMPLIANCE WITH SECTION 307.2
 PROTRUSION LIMITS, THE REQUESTED PLUMBING FIXTURE
 CALCULATIONS WERE NOT SUBMITTED AND NEW PLAN SHEET
 P00.01 SHOWING THE OVERALL FLOOR PLAN AND LOCATION OF
 THE DRINKING FOUNTAIN WAS NOT UPLOADED.
  
 7) COMMENT #7J FROM THE 1ST REVIEW- FAILED. SHOW THE
 CLEAR FLOOR SPACE APPROACHES TO THE SINKS AND FIXTURES
 IN THE CUSTOMER AND COLLEAGUE PANTRIES- SECTION 305 FBC
 ACC. FORWARD APPROACH CLEAR FLOOR SPACE DIAGRAMS ARE
 SHOWN ON REVISED SHEET A02.01, HOWEVER THE ELEVATION
 DETAIL ON A11.03 DOES NOT SHOW THE REQUIRED KNEE AND
 TOE CLEARANCES- SECTION 306 FBC ACC.
  
 8) COMMENT #8 FROM THE 1ST REVIEW- FAILED. SHEET A00.33
 CODE DATA WAS NOT UPLOADED FOR REVIEW. PLEASE PROVIDE
 THE PLAN SHEET- SECTION 107.2.1 WPB.
  
 9) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SECTION
 105.1 WPB. PLEASE NOTE THAT THERE IS NO FEE FOR A
 SUB-PERMIT THAT IS ISSUED WITH THE PRIMARY PERMIT,
 HOWEVER THERE IS A FEE FOR SUB-PERMITS APPLIED FOR
 AFTER PRIMARY PERMIT ISSUANCE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-12-04 Cont ID  
Sent By ccole Date 2020-12-04 Time 09:15 Rev Time 0.00
Received By ccole Date 2020-12-04 Time 07:09 Sent To  
Notes
2020-12-04 09:15:181ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20110703
 12/4/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P00.01: PROVIDE PLUMBING FIXTURE CALCULATIONS
 AND A SCHEDULE SHOWING THE REQUIRED AND PROVIDED
 FIXTURES IN COMPLIANCE WITH TABLE 403.3 FBC P. PLEASE
 NOTE THAT DRINKING FOUNTAINS AND A SERVICE SINK ARE
 REQUIRED FIXTURES FOR BUSINESS OCCUPANCIES.
  
 2) P01.03, SANITARY ISOMETRIC: SHOW A TRAP AT SK-1
 LOCATION. WATER ISOMETRIC: IDENTIFY ALL FIXTURES AND
 SHOW REQUIRED SHUT OFF VALVES AT ALL FIXTURE AND
 APPLIANCE LOCATIONS- SECTION 107.3.5.3 WPB, AND SECTION
 606.2 FBC P.
  
 3) P01.03 WATER ISOMETRIC: SHOW LOCATIONS OF WATER
 HAMMER ARRESTORS, MIXING VALVE AT THE LAVATORY, AND
 BACKFLOW PREVENTERS AT COFFEE MAKER, ICE MAKER
 LOCATIONS- REFER TO SECTIONS 604.9, 416.5, 607.1.2, &
 608.3 FBC P.
  
 4) P02.01: ADD THE MIXING VALVE TO THE LAVATORY
 DETAILS- SECTIONS- 416.5, AND 607.1.2. PLEASE NOTE THAT
 THE POINT OF USE WATER HEATER AT THIS LOCATION SHALL BE
 ASSE 1070 LISTED AND LABELED OR THE MIXING VALVE SHALL
 BE PROVIDED.
  
 5) P02.01: PROVIDE THE EFFICIENCY RATINGS OF THE WATER
 HEATERS IN THE SCHEDULE- TABLE C404.2 FBC EC.
  
 6) P02.01: PLEASE PROVIDE A DEVICE SCHEDULE SHOWING
 MAKES, MODELS AND LISTINGS OF THE WATER HAMMER
 ARRESTORS, MIXING VALVES, AND BACKFLOW PREVENTERS-
 SECTION 107.2.1 WPB.
  
 7) P02.01: ADD A NOTE TO THE SLAB REPAIR DETAIL TO
 INDICATE THE REQUIRED VAPOR BARRIER AND TERMITE
 TREATMENT WILL BE PROVIDED. PLEASE NOTE A COPY OF THE
 TERMITE CERTIFICATE SHALL BE ONSITE FOR FINAL
 INSPECTION APPROVAL- SECTION 107.2.1 WPB.
  
 7) ACCESSIBLE PLUMBING FIXTURE REQUIREMENTS PER FBC
 ACC. THE DRAWINGS AND DETAILS ON SHEETS A02.01 & A11.03
 ARE INCOMPLETE. PLEASE REVISE THE SHEETS TO SHOW:
  
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSION FOR THE
 WATER CLOSET- SECTION 604.3.
  
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORY- SECTION 606.2.
  
 C) TURNING SPACE DIAMETER- SECTION 304.3.
  
 D) HEIGHT OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOOR- SECTION 604.4.
  
 E) KNEE AND TOE CLEARANCES FOR THE LAVATORY- SECTION
 306.
  
 F) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION
 604.6.
  
 G) HEIGHT OF THE MIRROR FROM THE FINISHED FLOORS TO THE
 BOTTOM OF THE REFLECTIVE SURFACE- SECTION 603.3.
  
 H) AS NOTED IN COMMENT #1 DRINKING FOUNTAINS ARE
 REQUIRED FIXTURES AND SHALL BE ACCESSIBLE IN ACCORDANCE
 WITH SECTIONS 211.2 & 602.1- 602.6 FBC ACC. PROVIDE
 DRAWINGS AND DETAILS SHOWING: A) THE 30 X 48 IN. CLEAR
 FLOOR SPACE FOR A FORWARD APPROACH TO THE WHEELCHAIR
 ACCESSIBLE DRINKING FOUNTAIN- SECTION 602.2 FBC ACC. B)
 KNEE AND TOE CLEARANCES, SPOUT HEIGHTS, SPOUT
 LOCATIONS- SECTIONS 306, 307, & 602.2. C) COMPLIANCE
 WITH SECTION 307.2 PROTRUSION LIMITS.
  
 I) THE PLUMBING PLANS SHOW A WATER COOLER IN THE
 CUSTOMER PANTRY WHICH IS NOT SHOWN ON THE ARCHITECTURAL
 PLANS AND ELEVATION DETAIL. PLEASE CLEARLY SHOW THE
 COOLER ON THE PLANS AND ACCESSIBILITY REQUIREMENTS
 INCLUDING CLEAR FLOOR SPACE APPROACH AND REACH RANGES
 TO CONTROLS- SECTIONS 305 & 308 FBC ACC.
  
 J) SHOW THE CLEAR FLOOR SPACE APPROACHES TO THE SINKS
 AND FIXTURES IN THE CUSTOMER AND COLLEAGUE PANTRIES-
 SECTION 305 FBC ACC.
  
 8) SHEET A00.33 CODE DATA WAS NOT UPLOADED FOR REVIEW.
 PLEASE PROVIDE THE PLAN SHEET- SECTION 107.2.1 WPB.
  
 9) INDICATE THE TYPE OF WALL FINISHES TO BE INSTALLED
 IN THE RESTROOM AND AT THE MOP SINK LOCATION IN
 ACCORDANCE WITH SECTION 310.3 FBC P, AND 1210.2.2 FBC
 B.
  
 10) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SECTION
 105.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-02-16 Cont ID  
Sent By shill Date 2021-02-16 Time 12:44 Rev Time 0.00
Received By shill Date 2021-02-16 Time 12:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2021-01-19 Cont ID  
Sent By medwards Date 2021-01-19 Time 06:31 Rev Time 0.00
Received By medwards Date 2021-01-19 Time 06:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-11-27 Cont ID  
Sent By medwards Date 2020-11-27 Time 10:28 Rev Time 0.00
Received By medwards Date 2020-11-27 Time 10:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2021-02-04 Cont ID  
Sent By elevesqu Date 2021-02-04 Time 11:28 Rev Time 0.00
Received By elevesqu Date 2021-02-04 Time 11:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2021-01-20 Cont ID  
Sent By elevesqu Date 2021-01-20 Time 16:48 Rev Time 0.00
Received By elevesqu Date 2021-01-20 Time 16:48 Sent To  
Notes
2021-01-20 16:48:33REPEAT COMMENTS:
  
 PLEASE INDICATE THROUGH AERIAL VIEW AND/OR SITE IMAGES
 EXACT LOCATION OF TENANT SPACE. PLEASE ADD SUITE NUMBER
 TO PLANS AND PERMIT (SEE ADDRESSING COMMENTS REGARDING
 LEGAL SUITE NUMBER)
  
 PLEASE PROVIDE EXTERIOR ELEVATIONS
  
 PLEASE NOTE, PHILLIPS POINT HAS AN APPROVED SIGN
 PROGRAM AS A PLANNED DEVELOPMENT. ANY PROPOSED EXTERIOR
 SIGNAGE WILL NEED TO FOLLOW THE APPROVED SIGN PACKET
 AND REQUIRES A SEPARATE PERMIT
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-28 Cont ID  
Sent By elevesqu Date 2020-12-28 Time 14:26 Rev Time 0.00
Received By elevesqu Date 2020-12-28 Time 14:11 Sent To  
Notes
2020-12-28 14:15:57PLEASE INDICATE THROUGH AERIAL VIEW AND/OR SITE IMAGES
 EXACT LOCATION OF TENANT SPACE. PLEASE ADD SUITE NUMBER
 TO PLANS AND PERMIT
  
 PLEASE PROVIDE EXTERIOR ELEVATIONS
  
 PLEASE NOTE, PHILLIPS POINT HAS AN APPROVED SIGN
 PROGRAM AS A PLANNED DEVELOPMENT. ANY PROPOSED EXTERIOR
 SIGNAGE WILL NEED TO FOLLOW THE APPROVED SIGN PACKET
 AND REQUIRES A SEPARATE PERMIT
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]
  
  