| Plan Review Stops For Permit 20110675 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-25 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-25 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-09 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2021-02-09 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-09 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2021-02-09 09:34:14 | ADDITION AND REMODEL GUEST HOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWINGS NEED TO BE SIGNED AND SEALED BY THE | | | DESIGNER. (PREVIOUS DRAWINGS UPLOADED TO PROJECTDOX ON | | | 11/17/2020 NEED TO BE SIGNED AND SEALED) | | | 2) THE BUILDING DEMO PERMIT NEEDS TO BE APPROVED BEFORE | | | THIS PERMIT (PLEASE E MAIL [email protected] AND THE | | | [email protected] WHEN THE FEES FOR PERMIT | | | 21020019 ARE PAID SO THE PERMIT CAN BE PROCESSED) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-10 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-10 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2020-12-10 12:51:11 | ADDITION AND REMODEL GUEST HOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWINGS NEED TO BE SIGNED AND SEALED BY | | | THEDESIGNER. | | | 2) PLEASE SHOW THE CEILING HEIGHT TO COMPLY WITH FBC | | | R305.1 | | | 3) PLEASE SHOW THE REQUIRED EXTERIOR WATER BARRIER - | | | FBC R703.2 WATER-RESISTIVE BARRIER. ONE LAYER OF NO. 15 | | | ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING | | | WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED | | | WATER-RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR | | | SHEATHING OF ALL EXTERIOR WALLS. | | | 4) PLEASE SHOW THE WALL AND CEILING INSULATION TYPE AND | | | "R" VALUE ON THE DRAWINGS. | | | 5) PLEASE SHOW THE VENTILATION TYPE AND LOCATION FOR | | | THE ROOF RAFTERS - FBC R806.1VENTILATION REQUIRED. | | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | | ENTRANCE OF RAIN OR SNOW. | | | 6) PLEASE PROVIDE THE STRUCTURAL DETAILS SHOWING ALL | | | ATTACHMENTS FOR THE ADDED ROOFING OUTLOOKERS SHOWN ON | | | DRAWING A501. | | | 7) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE OVERHEAD DOORS. | | | 8) YOU UPLOADED A STOREFRONT PRODUCT APPROVAL TO THE | | | SUPORTING DOC. FOLDER - PLEASE SHOW THE LOCATION FOR | | | THE STOREFRONT GLASS SYSTEM ON THE FLOOR PLAN. | | | 9) THE BUILDING DEMO NEEDS TO BE ON A SEPARATE PERMIT - | | | PLEASE PROVIDE THE DEMO PERMIT NUMBER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-09 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-09 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-17 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-17 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-25 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-18 |
Time |
11:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-09 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-29 |
Time |
07:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-23 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-02 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-12-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-05 |
Time |
07:15 |
Rev Time |
|
| Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-03 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-03 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-25 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-25 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-02-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-09 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-09 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2021-02-09 09:39:16 | PREVIOUS DRAWINGS UPLOADED TO PROJECTDOX ON 11/17/2020 | | | = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE ? YOU CAN MAIL IN OR DROP OFF THE | | | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS TO THE | | | FRONT DESK IN THE BUILDING DEPT. AT THE CITY HALL |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-12-03 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-12-03 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2020-12-03 08:50:52 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DIGITAL SIGNATURE OF DESIGN PROFESSIONAL REQUIRED. | | | | | | | | | 2 EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR | | | DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL | | | WET SEAL AND SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-12-17 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-12-17 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|