Plan Review Details - Permit 20110624
| Plan Review Stops For Permit 20110624 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-12-22 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-12-22 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-23 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-23 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2020-11-23 14:13:06 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE ENGINEER'S SIGNED/SEALED | | | CALCULATIONS FOR UPLIFT PRESSURES AND FASTENER SPACING | | | AT ROOF ZONES 2 AND 3. | | | (THE PRODUCT APPROVAL LIMITATION #9 DOES NOT APPLY AS | | | THE SELECTED SYSTEM'S UPLIFT PRESSURE CAPACITY DOES NOT | | | MEET THE REQUIRED UPLIFT PRESSURES. THEREFORE, PRODUCT | | | APPROVAL LIMITATION # 7 APPLIES). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-16 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-16 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2020-11-16 10:44:08 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561?805?6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE SELECT THE SYSTEM WITHIN THE | | | SUBMITTED NOA THAT WILL BE USED AND PROVIDE ENGINEER'S | | | SIGNED/SEALED LETTER PER LIMITATION #7 (PAGE 38 OF THE | | | NOA), IF APPLICABLE PER SYSTEM REQUIREMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-12-22 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-12-21 |
Time |
22:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-23 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-23 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-20 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-16 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-13 |
Time |
20:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-12-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-12-22 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2020-12-22 14:02:47 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED BY PAPER ORIGINAL | | | SIGNED/SEALED ENGINEER'S LETTER. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-16 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-16 |
Time |
06:39 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |