Plan Review Details - Permit 20110624
Plan Review Stops For Permit 20110624
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-12-22 Cont ID  
Sent By pvalenti Date 2020-12-22 Time 14:02 Rev Time 0.00
Received By pvalenti Date 2020-12-22 Time 13:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-11-23 Cont ID  
Sent By pvalenti Date 2020-11-23 Time 14:05 Rev Time 0.00
Received By pvalenti Date 2020-11-23 Time 14:05 Sent To  
Notes
2020-11-23 14:13:06PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 2ND BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE PROVIDE ENGINEER'S SIGNED/SEALED
 CALCULATIONS FOR UPLIFT PRESSURES AND FASTENER SPACING
 AT ROOF ZONES 2 AND 3.
 (THE PRODUCT APPROVAL LIMITATION #9 DOES NOT APPLY AS
 THE SELECTED SYSTEM'S UPLIFT PRESSURE CAPACITY DOES NOT
 MEET THE REQUIRED UPLIFT PRESSURES. THEREFORE, PRODUCT
 APPROVAL LIMITATION # 7 APPLIES).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By pvalenti Date 2020-11-16 Time 10:39 Rev Time 0.00
Received By pvalenti Date 2020-11-16 Time 06:39 Sent To  
Notes
2020-11-16 10:44:08PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE SELECT THE SYSTEM WITHIN THE
 SUBMITTED NOA THAT WILL BE USED AND PROVIDE ENGINEER'S
 SIGNED/SEALED LETTER PER LIMITATION #7 (PAGE 38 OF THE
 NOA), IF APPLICABLE PER SYSTEM REQUIREMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-12-22 Cont ID  
Sent By pvalenti Date 2020-12-22 Time 14:03 Rev Time 0.00
Received By pvalenti Date 2020-12-21 Time 22:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-23 Cont ID  
Sent By pvalenti Date 2020-11-23 Time 14:13 Rev Time 0.00
Received By pvalenti Date 2020-11-20 Time 14:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-16 Cont ID  
Sent By pvalenti Date 2020-11-16 Time 10:44 Rev Time 0.00
Received By pvalenti Date 2020-11-13 Time 20:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-22 Cont ID  
Sent By pvalenti Date 2020-12-22 Time 14:01 Rev Time 0.00
Received By pvalenti Date 2020-12-22 Time 13:58 Sent To  
Notes
2020-12-22 14:02:47PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 SIGNATURE REVIEW APPROVED BY PAPER ORIGINAL
 SIGNED/SEALED ENGINEER'S LETTER.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-16 Cont ID  
Sent By pvalenti Date 2020-11-16 Time 10:44 Rev Time 0.00
Received By pvalenti Date 2020-11-16 Time 06:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved