Plan Review Details - Permit 20110226
Plan Review Stops For Permit 20110226
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-12-03 Cont ID  
Sent By cthroop Date 2020-12-03 Time 10:54 Rev Time 0.00
Received By cthroop Date 2020-12-03 Time 10:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 15:53 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 15:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-17 Cont ID  
Sent By cthroop Date 2020-11-17 Time 10:57 Rev Time 0.00
Received By cthroop Date 2020-11-17 Time 10:18 Sent To  
Notes
2020-11-17 11:04:45PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE WALL LEGEND FOR NEW INTERIOR PARTITIONS.
 107.2 CONSTRUCTION DOCUMENTS.
  
 2. PROVIDE DETAIL FOR NEW SUB-FLOORING. (FLOOR TYPE NOT
 SPECIFIED - SOG/WOOD JOIST).
 107.2 CONSTRUCTION DOCUMENTS.
  
 3. PROVIDE FOUNDATION DETAIL FOR NEW KITCHEN ISLAND.
 (SOG/WOOD JOIST SUB-FLOOR)
 IF SOG, PROVIDE SLAB REPAIR DETAIL.
 107.2 CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-12-03 Cont ID  
Sent By equinone Date 2020-12-03 Time 10:46 Rev Time 0.00
Received By equinone Date 2020-12-03 Time 10:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By equinone Date 2020-11-20 Time 15:09 Rev Time 0.00
Received By equinone Date 2020-11-20 Time 15:09 Sent To  
Notes
2020-11-20 15:10:34SEE SIGNATURE NOTES

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-11-18 Cont ID  
Sent By equinone Date 2020-11-18 Time 09:26 Rev Time 0.00
Received By equinone Date 2020-11-18 Time 09:26 Sent To  
Notes
2020-11-18 09:28:20SEE SIGNATURE REVIEW COMMENTS:
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANSL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2020-11-16 Cont ID  
Sent By lcrespo Date 2020-11-16 Time 13:26 Rev Time 0.00
Received By lcrespo Date 2020-11-16 Time 13:26 Sent To  
Notes
2020-11-16 13:26:24GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN
 PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS
 WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR
 FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC
 SEC. 105.1.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 11:07 Rev Time 0.00
Received By medwards Date 2020-12-01 Time 10:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 15:55 Rev Time 0.00
Received By cthroop Date 2020-11-19 Time 16:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-18 Cont ID  
Sent By equinone Date 2020-11-18 Time 09:28 Rev Time 0.00
Received By equinone Date 2020-11-10 Time 14:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2020-12-03 Cont ID  
Sent By medwards Date 2020-12-03 Time 11:07 Rev Time 0.00
Received By medwards Date 2020-12-03 Time 11:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By medwards Date 2020-11-20 Time 08:01 Rev Time 0.00
Received By medwards Date 2020-11-20 Time 07:33 Sent To  
Notes
2020-11-20 08:04:07APPROVED WITH PRIVISO:
  
 MASTER BATHROOM MUST ALSO HAVE AN EXHAUST FAN LOCATED
 IN THE TUB AREA. FBC RES R303.3, FBC M CHAPTER 2
 DEFINITION OF BATHROOM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 08:32 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 08:18 Sent To  
Notes
2020-11-12 08:35:12PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL
 SYSTEMS ON THIS PROJECT. PLEASE PROVIDE MECHANICAL
 DRAWINGS FOR THE SCOPE OF WORK. FBC 107.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-12-02 Cont ID  
Sent By lcrespo Date 2020-12-02 Time 09:02 Rev Time 0.00
Received By lcrespo Date 2020-12-02 Time 08:53 Sent To  
Notes
2020-12-02 09:02:5312/02/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By lcrespo Date 2020-11-20 Time 10:51 Rev Time 0.00
Received By lcrespo Date 2020-11-20 Time 10:51 Sent To  
Notes
2020-11-20 10:51:4711/20/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By lcrespo Date 2020-11-16 Time 13:27 Rev Time 0.00
Received By lcrespo Date 2020-11-16 Time 13:27 Sent To  
Notes
2020-11-16 13:42:1311/16/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1.
  
 2. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL
 PLUMBING.
  
 3. PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 4. PLEASE PROVIDE THE SIGNATURE OF ALL INFORMATION,
 DRAWINGS, SPECIFICATIONS, AND ACCOMPANYING DATA THAT
 SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN PER THE WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 5. A GAS RANGE IS SHOWN ON PLANS AND NOT NOTED, IF IT
 WILL BE MOVE PLEASE NOTE A SEPARATE GAS PERMIT WILL BE
 REQUIRED WITH A NARRATIVE OF THE SCOPEOF WORK PER THE
 WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-12-01 Cont ID  
Sent By medwards Date 2020-12-01 Time 14:31 Rev Time 0.00
Received By medwards Date 2020-12-01 Time 14:31 Sent To  
Notes
2020-12-01 14:32:49ORIGINAL PAPER PLANS FILED IN STORAGE. SIGNATURE REVIEW
 APPROVED. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-11-25 Cont ID  
Sent By cthroop Date 2020-11-25 Time 15:54 Rev Time 0.00
Received By cthroop Date 2020-11-25 Time 15:17 Sent To  
Notes
2020-11-25 15:55:19PLAN REVIEW / SIGNATURES
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET SEAL AND SIGNATURE OR
 DIGITAL SIGNATURE IS NOT CONSIDERED A DIGITAL
 SIGNATURE.
  
 2. EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR
 DROP OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL
 WET SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 08:37 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 08:37 Sent To  
Notes
2020-11-12 08:38:08PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved