| Plan Review Stops For Permit 20110119 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-26 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-26 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-04-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-04-08 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-04-08 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2021-04-08 16:50:45 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | DOORS. CORRECTED | | | | | | NEW COMMENTS: | | | | | | 2. REF: PLAN PAGE A-1. GOVERNING CODES STATED AS FBC | | | 2020 7TH ED. THIS PROJECT SHALL BE DESIGNED UNDER THE | | | FBC 2017 6TH ED. PLEASE CORRECT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. REF: PLAN PAGE A-2. IDENTIFY THE INSULATION TYPE AND | | | R-VALUE OF THE EXTERIOR MASONRY WALLS. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | | | | 4. PROVIDE AN ENERGY SUBMITTAL. CORRECTED | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-02-10 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-02-10 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2021-02-10 11:18:43 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | DOORS. CORRECTED | | | | | | NEW COMMENTS: | | | | | | 2. REF: PLAN PAGE A-1. GOVERNING CODES STATED AS FBC | | | 2020 7TH ED. THIS PROJECT SHALL BE DESIGNED UNDER THE | | | FBC 2017 6TH ED. PLEASE CORRECT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. REF: PLAN PAGE A-2. IDENTIFY THE INSULATION TYPE AND | | | R-VALUE OF THE EXTERIOR MASONRY WALLS. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | | | | 4. PROVIDE AN ENERGY SUBMITTAL. | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-19 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-19 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2020-11-19 12:53:01 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED WINDOWS AND | | | DOORS. | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-03-30 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-30 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-30 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-02-11 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-11 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-09 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2021-02-11 16:14:49 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | | | | 1) ELECTRICAL DRAWING SUBMITTED FOR GAS WATER HEATER | | | NOT CLEAR: | | | ? BOX LABELED ?EXISTING OUTDOOR LIGHTING?: IS THIS A | | | SUBPANEL, JUNCTION BOX? PLEASE CLARIFY FBC 107 | | | ? BOX IS LABELED EXISTING OUTDOOR LIGHTING, BUT DIAGRAM | | | MENTIONS THAT YOU ARE ADDING 2#12 CU CONDUCTORS TO FEED | | | THE BOX. IS THERE AN EXISTING CIRCUIT TO THE BOX BEING | | | REPLACED? FBC 107 | | | ? CIRCUIT FROM EXISTING CUTTLER HAMMER PANEL TO | | | ?EXISTING OUTDOOR LIGHTING? BOX SHOWS 2#12 CONDUCTORS | | | WITH NO EQUIPMENT GROUNDING. PLEASE SPECIFY EQUIPMENT | | | GROUNDING. NEC 250 | | | ? WHAT IS THE SIZE OF CONDUCTORS CONNECTING TO THE | | | ?EXISTING OUTDOOR LIGHTING?? WHAT IS THE EXISTING LOAD | | | ON THIS CIRCUIT? WHAT WILL BE THE TOTAL LOAD ON THIS | | | CIRCUIT IF IT IS ALSO FEEDING THE GAS WATER HEATER? | | | | | | 2) ELECTRICAL DRAWING FOR GAS WATER HEATER MUST HAVE | | | THE NAME AND SIGNATURE OF CONTRACTOR QUALIFIER | | | PREPARING THE DRAWINGS FBC 107 | | | 3) NEW A-3 MEP DRAWINGS SUBMITTED ARE DISTORTED AND | | | DIFFICULT TO READ. | | | 4) ELECTRICAL SUB-PERMIT REQUIRED | | | 5) PLEASE SEE ALSO SIGNATURE COMMENTS FOR DRAWINGS FBC | | | 107 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-20 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-20 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2020-11-20 11:54:32 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. | | | | | | 1) AT LEAST ONE ADDITIONAL RECEPTACLE REQUIRED ON | | | BEDROOM (WALL NEXT TO DOOR OR CLOSET WALL). PLEASE | | | VERIFY REST OF RECEPTACLE SPACING. NEC 210.52 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-24 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-24 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2021-03-24 10:19:57 | 03/24/21 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-10 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-10 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2021-02-10 11:14:51 | 02/10/21 1ST REVIEW PLUMBING REVIEW**DENIED** WITH | | | COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. THE RESIDENCE'S PHYSICAL ADDRESS MUST BE ON PLANS IN | | | FULL, NUMBER, STREET, CITY, STATE, AND ZIP CODE PER THE | | | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 2. PLEASE HAVE A SIGNATURE ON THE ISOMETRIC DRAWING OF | | | THE PERSON DESIGNING THE SYSTEM, NOT IN ACCORDANCE WITH | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.001, FLORIDA | | | STATUTE 471 PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.1 GENERAL. | | | | | | 3. SHOW THE TYPE OF PIPE MATERIAL BEING INSTALLED THE | | | ISOMETRIC, ALL PIPE SIZES, AND THE CORRESPONDING EHD | | | NUMBER OF THE CORRUGATED STAINLESS-STEEL TUBING (IF | | | APPLICABLE) FOR EACH PIPE SIZE PER THE WPB AMENDMENTS | | | TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 4. THIS TANK-LESS UNIT CALL FOR A 10.5" WATER COLUMN, | | | AND THE SERVICE METER DISCHARGES IS A 12" WATER COLUMN | | | REQUIRING A REGULATOR FOR THIS UNIT AS PER THE | | | MANUFACTURER'S SPECIFICATION. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | | INSTALLED ON THE BUILDING'S EXTERIOR SHALL BE APPROVED | | | FOR OUTDOOR INSTALLATION PER THE 2020 FBC RES. SEC. | | | G2421.1. | | | | | | 5. PLEASE PROVIDE THE TANK-LESS WATER HEATER'S LOCATION | | | AND THE DISTANCE OF ANY OPERABLE DOORS OR WINDOWS IN | | | RELATION TO THE WATER HEATER. THE WATER HEATER'S | | | LOCATION SHALL COMPLY WITH THE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | 6. THE CLAIMED VALUE APPEARS TO BE UNDERESTIMATED ON | | | THE APPLICATION. PLEASE PROVIDE A BONA FIDE SIGNED | | | CONTRACT. THE OVERALL VALUE IS LOW. SUPPOSE, IN THE | | | BUILDING OFFICIAL'S OPINION, THE BUILDING'S CLAIMED | | | VALUATION, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION. IN THAT CASE, THE | | | PERMIT SHALL BE DENIED UNLESS THE APPLICANT CAN SHOW | | | DETAILED QUANTITY ESTIMATES AND BONA FIDE SIGNED | | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE BUILDING | | | OFFICIAL'S APPROVAL. FOR PERMITTING PURPOSES, THE | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD, AND PROFIT, EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS POSTED BY | | | INTERNATIONAL CODE CONGRESS. THE BUILDING OFFICIAL'S | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 109.3 BUILDING PERMIT | | | VALUATIONS. | | | | | | 7. PLEASE PROVIDE THE TYPE OF GAS (LP OR NATURAL) PER | | | THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 8. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM | | | ON THE PLAN PER THE 2020 FBC FG SEC. 402.2 OR 2020 FBC | | | RES. SEC. G2413.2. | | | | | | 9. PLEASE LIST EACH APPLIANCE'S BTU LOAD AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. THE BTU LOAD OF THE EXISTING | | | GAS SYSTEM MUST BE ADDED TO THE TOTAL BTU LOAD ON THE | | | SYSTEM TO ENSURE THE EXISTING SYSTEM IS SIZED | | | CORRECTLY. IF UNDERSIZED, THE EXISTING SYSTEM MUST BE | | | REDONE TO ENSURE A SAFE OPERATING SYSTEM PER THE 2020 | | | FBC RES. SECS. G2412.4, G2412.8, G2413.1, G2413.2, | | | G2413.3. | | | | | | 10. SHOW THE DISTANCE FROM THE POINT OF DELIVERY (GAS | | | METER / MP REGULATOR / LP TANK) TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND SYSTEM PER THE 2020 FBC RES. | | | SEC. G2413.4.1. | | | | | | 11. SUBMIT MANUFACTURER'S SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR GAS RANGE EQUIPMENT TO | | | VERIFY COMPLIANCE, AND GAS APPLIANCES SHALL BE LISTED | | | AND LABELED PER THE 2020 FBC RES. SEC. G2408.1. | | | | | | 12. PLEASE SUBMIT A COPY OF THE SIZING TABLE USED IN | | | THE DESIGN FOR THE GAS SYSTEM OR PLACE A NOTE ON BOTH | | | SETS OF PLANS LISTING THE SIZING TABLES FROM GAS CODES | | | OR ANOTHER STANDARD USED IN THE DESIGN OF THIS SYSTEM | | | PER THE 2020 FBC RES. SEC. G2413.3. | | | | | | 13. PLEASE SHOW AND LABEL UNION IN FRONT OF REGULATOR | | | 1' OF EITHER SIDE PER THE 2020 FBC RES. SEC G2421.2. | | | | | | 14. PLEASE SHOW AND LABEL THE SHUTOFF VALVES ON GAS | | | ISOMERIC. PLEASE NOTE THAT THE STOVE'S VALVE SHALL BE | | | ACCESSIBLE WITHOUT MOVING THE UNIT PER THE 2020 FBC | | | RES. SEC. G2401.1.3. | | | | | | 15. PLEASE SHOW AND LABEL DRIP LEG ON EQUIPMENT | | | INSTALLED, EXCEPT FOR APPLIANCES, RANGE, DRYERS & OD | | | GRILLS PER THE 2020 FBC RES. SEC. G2419.2. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-07-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-16 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-06-22 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-06-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-06-03 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-03 |
Time |
09:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-15 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-22 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-02 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-22 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-04 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-04 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-06 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-07-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-21 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-07-16 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2021-07-20 13:56:22 | RECEIPT MU-2021-35103 - $1945.04 - PAID | | 2021-07-16 12:31:10 | 7/16/21 EMAILED IMPACT FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-19 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-19 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2020-11-19 12:54:19 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-05-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-12 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-05-12 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2021-05-12 16:07:27 | APPROVED WITH PRIVISO: | | | | | | THE BEDROOM MUST HAVE A RETURN AIR PATH BACK TO THE | | | AHU. NOTE: IT SHOULD NOT PASS THROUGH THE BATHROOM. FBC | | | RES M1602.3 & M1602.2(4) | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-31 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-31 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2021-03-31 15:54:42 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-20110119 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A MECHANICAL EQUIPMENT SIZING | | | CALCULATION TO SHOW THAT THE EXISTING EQUIPMENT IS | | | SIZED LARGE ENOUGH TO SUPPORT THE ADDITIONAL LOAD OF | | | THE ADDED SQUARE FOOTAGE. FBC EC C403.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-09 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-09 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2021-02-09 08:52:44 | PLEASE ADDRESS ORIGINAL MECHANICAL REVIEW COMMENTS | | | LISTED BELOW. | | | | | | | | | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20110119 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING FOR THIS | | | ADDITION TO THE EXISTING EQUIPMENT. PLEASE SHOW THAT | | | THE EXISTING EQUIPMENT IS SIZED TO HANDLE THE | | | ADDITIONAL LOAD. FBC EC R403.7.1 | | | | | | 3) PLEASE SHOW RETURN AIR PATH FROM NEW BEDROOM BACK TO | | | THE EXISTING AHU. FBC RES M1602.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-09 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-09 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2020-11-09 11:03:31 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20110119 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING FOR THIS | | | ADDITION TO THE EXISTING EQUIPMENT. PLEASE SHOW THAT | | | THE EXISTING EQUIPMENT IS SIZED TO HANDLE THE | | | ADDITIONAL LOAD. FBC EC R403.7.1 | | | | | | 3) PLEASE SHOW RETURN AIR PATH FROM NEW BEDROOM BACK TO | | | THE EXISTING AHU. FBC RES M1602.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-24 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2021-03-24 10:14:05 | 03/24/21 3RD PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING RISER DIAGRAM PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | NO P-1 FOUND | | | | | | 2. NOTED. | | | | | | 3. DONE. | | | | | | 4. DONE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-10 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-10 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-10 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2021-02-10 10:31:17 | 02/10/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING RISER DIAGRAM PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 2. THE GAS HEATER IS IN A SEPARATE BUILDING ACCORDING | | | TH THE NEW GAS DRAWING AND IF IT GOING TO HAVE LINE TO | | | THE NEW STRUCTURE PLEASE PROVIDE VERBIAGE ON PLAN PER | | | THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 3. PIPES NOT IN CONDITION SPACE RUNNING TO THE NEW | | | STRUCTURE NEED TO BE INSULATED WITH A MINIMUM R-3 PER | | | THE 2017 FBC SEC. RE 403.5.3. | | | | | | 4. SIGNED AND SEALED DRAWINGS NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - | | | IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL | | | SIGNATURE - PLEASE DROP OFF (CITY HALL DROPBOX) THE | | | ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN | | | REVIEW REQUEST FORM" EXPLAINING THE REASON FOR | | | SUBMITTING THE DOCUMENT OR DRAWINGS. THE PLAN REVIEW | | | REQUEST FORM CAN BE OBTAINED BY EMAILING [email protected] AND | | | ASKING FOR THE FORM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-19 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-19 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2020-11-19 09:46:44 | 11/19/20 1STPLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE A PLUMBING RISER DIAGRAM PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 2. PLEASE PROVIDE A SOURCE OF HOT WATER AND THE | | | LOCATION OF CONNECTION PER THE 2017 FBC SEC. FBC R | | | 2722.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-19 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-19 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2020-11-19 12:50:19 | EXISTING ROOF. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-26 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-26 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2021-05-26 17:08:54 | SEE FRONT SCREEN NOTE. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-22 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-22 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2021-03-22 09:18:39 | PAPER DRAWINGS, ENERGY CALCULATONS HAVE ORIGINAL SEAL | | | AND SIGNATURE. ROUTED TO STORAGE. EQ |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-02-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-09 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-09 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2021-02-09 08:55:27 | PLEASE ADDRESS ORIGINAL SIGNATURE REVIEW COMMENTS | | | LISTED BELOW. | | | | | | DESIGNER OF THE DRAWINGS MUST DIGITSLLY SIGN AND SEAL | | | THE DRAWINGS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-11-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-09 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-09 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2020-11-09 11:08:17 | DESIGNER OF THE DRAWINGS MUST DIGITSLLY SIGN AND SEAL | | | THE DRAWINGS. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-07-15 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-07-15 |
Time |
15:52 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2021-06-02 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-06-02 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-06-02 |
Time |
17:05 |
Sent To |
I |
|
| Notes |
| 2021-06-02 17:06:34 | PREVIOUS ZONING COMMENTS NOT ADDRESSED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2021-04-14 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-04-14 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-04-14 |
Time |
08:10 |
Sent To |
I |
|
| Notes |
| 2021-04-14 08:14:38 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PLEASE ILLUSTRATE THE FOLLOWING ON THE SURVEY: | | | - LOCATION OF THE PROPOSED ADDITION/WORK. | | | - SETBACK DIMENSIONS FROM ANY EXTERIOR IMPROVEMENTS TO | | | ALL ADJACENT PROPERTY LINES. | | | | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-03-01 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-03-01 |
Time |
08:34 |
Sent To |
I |
|
| Notes |
| 2021-03-01 08:45:35 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PREVIOUS ZONING COMMENTS NOT ADRESSED. PROVIDE A | | | PROPERTY SUREVEY INDICATIONG LOCATION OF PROPOSED WORK | | | AS WELL AS THE SETBACK DIMENSIONS FROM ANY EXTERIOR | | | IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT | | | TO THE ZLDR, SECTION 94-72(A)(2): SINGLE-FAMILY LOW | | | DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM SETBACKS | | | FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, | | | WHICHEVER IS LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-04 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-12-04 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-12-04 |
Time |
13:56 |
Sent To |
I |
|
| Notes |
| 2020-12-04 13:59:03 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PROVIDE A PROPERTY SURVEY INDICATING LOCATION OF | | | PROPOSED WORK AND SETBACKS FROM PROPERTY LINE. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|