| Plan Review Stops For Permit 20110110 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-04-29 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-04-29 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2021-04-29 12:19:31 | ADDRESS CHANGED FRO 201 BLOOMFIELD DR TO 6255 | | | WASHINGTON RD. GUEST HOUSE CHANGED TO FITNESS CABANA | | | ACCESSORY UNIT NO LONGER NEEDS SECOND ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2021-04-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-04-20 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-04-20 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2021-04-20 16:43:42 | COMMENTS NOT ADDRESSED: | | | PRIMARY ADDRESS NEEDS TO BE CHANGED DUE TO THE NEW | | | FOOTPRINT OF THE PROPOSED PROPERTY AND THE CITY'S | | | CENTERLINES. THE GUEST HOUSE WILL ALSO NEED ITS OWN | | | ADDRESS. PLEASE CONTACT [email protected] TO DISCUSS | | | ADDRESSING ALLOCATIONS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-11-18 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-11-18 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2020-11-18 09:28:33 | PRIMARY ADDRESS NEEDS TO BE CHANGED DUE TO THE NEW | | | FOOTPRINT OF THE PROPOSED PROPERTY AND THE CITY'S | | | CENTERLINES. THE GUEST HOUSE WILL ALSO NEED ITS OWN | | | ADDRESS. PLEASE CONTACT [email protected] TO DISCUSS | | | ADDRESSING ALLOCATIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-25 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-25 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-21 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-21 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2021-06-21 11:19:55 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, PLEASE PROVIDE THE PRODUCT APPROVAL | | | NUMBERS TO EACH OPENING LETTER DESIGNATION ON | | | WINDOW/DOOR SCHEDULE LOCATED AT SHEET 3 OF 14. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-17 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-17 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2021-06-17 16:49:38 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | NOTE: THE ITEMS LISTED BELOW ARE THE ITEMS THAT STILL | | | NEED TO BE ADDRESSED FROM LAST REVIEW: | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GUEST HOUSE. | | | PRO-RATE THE VALUES AS FOLLOWS: MAIN HOUSE $531, 076.00 | | | AND GUEST HOUSE $93, 924.00. | | | SUBMIT THE GUEST HOUSE PERMIT TO | | | [email protected]. PLANS FOR BOTH STRUCTURES WILL | | | REMAIN UNDER 20110110. | | | | | | 3) FBC B 1803.1, PROVIDE A SOILS REPORT, THIS REPORT | | | NEEDS TO INCLUDE A DESIGN PROFESSIONAL APPROVED | | | GEO-TECHNICAL INVESTIGATION REPORT. | | | | | | 5) FBC B 107.2/FBC EC 101.5.1.1.2, SUBMIT A COMPLETED | | | ENERGY (RESIDENTIAL) FORM R405. | | | | | | 8) FBC B 107.2, PROVIDE THE PRODUCT APPROVALS/NOA'S | | | (REVIEW STAMPED BY DESIGNER OF RECORD) FOR ALL WINDOWS | | | & DOORS TO BE INSTALLED. ALSO ON SHEET 3 OF 14, PROVIDE | | | THE PRODUCT APPROVAL/NOA AT EACH OPENING DESIGNATION ON | | | OPENING SCHEDULE FOR WINDOWS AND DOORS. | | | | | | 9) FBC B 107.3.4.1, FOR ALL PRODUCT APPROVALS AND | | | PRODUCT SUBMITTALS TO BE DEFERRED, PROVIDE A LIST OF | | | THEM ON CONTRACT DRAWINGS INCLUDING: WINDOWS/DOORS AND | | | ROOFING MATERIALS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-04 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2021-05-04 14:24:24 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC 2014 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | A SEPERATE PERMIT IS REQUIRED FOR THE GUEST HOUSE. | | | PRO-RATE THE VALUES AS FOLLOWS: MAIN HOUSE $531,076 AND | | | GUEST HOUSE $93,924. | | | SUBMIT THE GUEST HOUSE PERMIT APPLICATION TO - | | | [email protected] | | | PLANS FOR BOTH STRUCTURES WILL REMAIN UNDER 20110110 - | | | MAIN HOUSE. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. PROVIDE A SITE DRAINAGE PLAN. | | | | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2. PROVIDE THE FINISHED FLOOR ELEVATION. | | | | | | FINISH FLOOR ELEVATION NON-FLOOD ZONE | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 3. PROVIDE A SOILS REPORT. | | | | | | GEOTECHNICAL INVESTIGATIONS | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 4.NOTICE ONLY: PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | SEE COMMENTS UNDER IMPACT FEE REVIEW. | | | | | | 5. STATE R VALUE OF 3/4" RIGID WALL INSULATION ON PLAN. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 6. COMPLETE | | | | | | 7. COMPLETE | | | | | | 8. DESINER SHALL SELECT MODEL OF SGD TO BE INSTALLED. | | | NOTICE: | | | OPENING PROTECTION REQUIRED IF N0N-IMPACT RATED DOOR | | | SELECTED. | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | 9. NOTICE ONLY: SUBMIT A ROOFING SUB-PERMIT AND | | | REQUIRED PRODUCT APPROVALS OR A PROVISO WILL BE PLACED | | | ON THE PLAN "SEPERATE ROOFING PERMIT REQUIRED.". | | | | | | PERMITS - 105.1 REQUIRED. | | | | | | PROVISO: PROVIDE ICC-ES REPORT FOR SPRAY FOAM | | | INSULATION TO CITY INSPECTOR. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | ***THESE COMMENTS APPLY TO BOTH STRUCTURES AND WILL BE | | | TRANSFERRED TO NEW GUEST HOUSE PERMIT*** | | | | | | ***REDLINED ADDRESS ON ALL PLAN PAGES PER SH*** | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-18 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-18 |
Time |
06:15 |
Sent To |
|
|
| Notes |
| 2020-11-18 11:03:22 | PLAN REVIEW / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC 2014 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | A SEPERATE PERMIT IS REQUIRED FOR THE GUEST HOUSE. | | | PRO-RATE THE VALUES AS FOLLOWS: MAIN HOUSE $531,076 AND | | | GUEST HOUSE $93,924. | | | SUBMIT THE GUEST HOUSE PERMIT APPLICATION TO - | | | [email protected] | | | PLANS FOR BOTH STRUCTURES WILL REMAIN UNDER 20110110 - | | | MAIN HOUSE. | | | | | | 1. PROVIDE A SITE PLAN. DRAINAGE/SURVEY | | | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 2. PROVIDE THE FINISHED FLOOR ELEVATION. | | | | | | FINISH FLOOR ELEVATION ? NON-FLOOD ZONE | | | R403.1.7.3 FOUNDATION ELEVATION. | | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER | | | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED | | | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 | | | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO | | | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN | | | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF | | | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT | | | ALL LOCATIONS ON THE SITE. | | | | | | 3. PROVIDE A SOILS REPORT. | | | | | | GEOTECHNICAL INVESTIGATIONS | | | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL | | | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | | DESIGN PROFESSIONAL. | | | | | | 4.NOTICE ONLY: PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | SEE COMMENTS UNDER IMPACT FEE REVIEW. | | | | | | 5. STATE R VALUE OF 3/4" RIGID WALL INSULATION ON PLAN. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | 6. PROVIDE AN ENERGY SUBMITTAL. | | | | | | PROVIDE ENERGY GAUGE FORM R405 PER SECTION R405.2 FBC | | | EC. | | | | | | 7. PROVIDE WINDOW AND DOOR SCHEDULES WITH THE FOLLOWING | | | INFORMATION: | | | 7A) WINDOW SCHEDULE - | | | 1. ITEM NUMBER | | | 2. LOCATION ON PLAN | | | 3. TYPE | | | 4. MFGR. | | | 5. MATERIAL | | | 6. GLASS TREATMENT | | | 7. ROUGH OPENING | | | 8. IMPACT RESISTANT Y/N | | | 9. PRODUCT APPROVAL NUMBER | | | 10. NOA DESIGN PRESSURE RATING | | | 11. OPENING REQUIRED PRESSURE RATING | | | 12. EGRESS REQUIRED Y/N | | | 13. SHUTTER REQUIRED Y/N | | | 7B) DOOR SCHEDULE | | | 1. ITEM NUMBER | | | 2. LOCATION ON PLAN | | | 3. SIZE | | | 4. THICKNESS | | | 5. TYPE | | | 6. MFGR. | | | 7. MATERIAL | | | 8. JAM | | | 9. ROUGH OPENING | | | 10. HARDWARE | | | 11. PRODUCT APPROVAL NUMBER | | | 12. NOA DESIGN PRESSURE RATING | | | 13. OPENING REQUIRED PRESSURE RATING | | | 14. SHUTTER REQUIRED Y/N | | | | | | 8. DESINER SHALL SELECT MODEL OF SGD TO BE INSTALLED. | | | NOTICE: | | | OPENING PROTECTION REQUIRED IF N0N-IMPACT RATED DOOR | | | SELECTED. | | | | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR | | | SUBMITTALS. | | | | | | 9. NOTICE ONLY: SUBMIT A ROOFING SUB-PERMIT AND | | | REQUIRED PRODUCT APPROVALS OR A PROVISO WILL BE PLACED | | | ON THE PLAN "SEPERATE ROOFING PERMIT REQUIRED.". | | | | | | PERMITS - 105.1 REQUIRED. | | | | | | PROVISO: PROVIDE ICC-ES REPORT FOR SPRAY FOAM | | | INSULATION TO CITY INSPECTOR. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | ***THESE COMMENTS APPLY TO BOTH STRUCTURES AND WILL BE | | | TRANSFERRED TO NEW GUEST HOUSE PERMIT*** | | | | | | ***REDLINE ADDRESS PER SH*** | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-06-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-06-07 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-06-07 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-04-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-04-28 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-04-28 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2021-04-28 10:59:05 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. SEE NEW COMMENTS BELOW | | | | | | 1) THIS PERMIT FALLS UNDER THE FBC 2017 7TH EDITION AND | | | NEC 2017. ELECTRICAL DRAWINGS ARE REFERING TO THE NEC | | | 2011. | | | PLEASE UPDATE NOTES TO REFERENCE THE RIGHT CODES. FBC | | | 107 | | | | | | 2) ELECTRICAL DRAWING SHOWS AN EMERGENCY GENERATOR AND | | | GENERATOR SWITCH THAT ARE NOT SHOWN ON RISER DIAGRAM. | | | PLEASE NOTE THAT THE EMERGENCY GENERATOR REQUIRES A | | | SEPARATE SUBMISSION AND SEPARATE ELECTRICAL PERMIT. | | | PLEASE ADD NOTE STATING THIS FACT. FBC 107 | | | | | | 3) PANELS A AND B ARE NOT LOCATED IN DETACHED | | | STRUCTURES. GROUNDING SHALL BE DONE WITH GROUNDING | | | EQUIPMENT CONDUCTORS NOT SEPARATE GROUNDING ELECTRODE | | | SYSTEMS. | | | PLEASE SPECIFY THE SIZE OF THE GROUNDING EQUIPMENT | | | CONDUCTORS FOR THOSE FEEDERS. NEC 250 | | | | | | 4) DOES THE MDP HAVE A MAIN CIRCUIT BREAKER AND | | | BREAKERS FOR FEEDERS TO PANELS A AND B? IF YES, PLEASE | | | PROVIDE BREAKER SIZES. | | | IF NOT PLEASE CLARIFY HOW FEEDERS TO PANELS A AND B ARE | | | PROTECTED? NEC 240 | | | | | | 5) GROUNDING NOTES ARE UNREADABLE. PLEASE SUBMIT NEW | | | DRAWING WITH READABLE NOTES. FBC 107 | | | | | | 6) WHAT IS THE ACTUAL RATING OF THE ELECTRICAL SERVICE? | | | THE SERVICE CONDUCTORS SPECIFIED ON RISER DIAGRAM ARE | | | FOR A 225 AMPS SERVICE AND MIGHT BE TOO SMALL DEPENDING | | | ON THE RATINGS OF THE MDP. | | | | | | 7) SMOKE DETECTORS ARE REQUIRED AS PER FBC RE 2020, 7TH | | | EDITION. PLEASE SHOW LOCATION OF ALL SMOKE DETECTORS. | | | | | | 8) PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | ELECTRICAL SERVICE INCLUDING INFORMATION FROM THE POWER | | | COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | | CURRENT IS. NEC 110.9, 110.10; FBC RE E3606.3 | | | | | | 9) GFI/WP RECEPTACLES ARE REQUIRED AT FRONT AND BACK OF | | | HOUSE. NEC 210.8 | | | | | | 10) SEPARATE GFI RECEPTACLE IS REQUIRED IN WASHER/DRYER | | | ROOM. NEC 210.8 | | | | | | 11) A MINIMUM OF ONE COMMUNICATIONS OUTLET SHALL BE | | | PROVIDED AS PER NEC 800.156. PLEASE SHOW LOCATION AND | | | ADD TO SYMBOLS. | | | | | | 12) PROVIDE COMPLIANCE: "NOT LESS THAN 90 PERCENT OF | | | THE LAMPS IN PERMANENTLY INSTALLED LUMINAIRES SHALL | | | HAVE | | | AN EFFICACY OF AT LEAST 45 LUMENS-PER-WATT OR SHALL | | | UTILIZE LAMPS WITH AN EFFICACY OF NOT LESS THAN 65 | | | LUMENS-PER-WATT?. | | | A NOTE WILL SUFFICE. FBC EC R404.1 | | | | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ PE | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-19 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-19 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2020-11-19 15:54:33 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. | | | | | | 1) PLEASE PROVIDE ELECTRICAL DRAWINGS FOR MAIN HOUSE. | | | INCLUDE RISER DIAGRAM, PANEL SCHEDULES, POWER AND | | | LIGHTING LAYOUT, SYSTEM GROUNDING, SERVICE EQUIPMENT | | | AND LOCATION, SMOKE ALARMS, LOAD CALCULATIONS, | | | AVAILABLE FAULT CURRENT, NOTES AND SYMBOLS. FBC 107 | | | 2) PLEASE PROVIDE PANEL SCHEDULE FOR GUEST HOUSE. FBC | | | 107 | | | 3) PLEASE SHOW LOCATION OF DISCONNECTING MEANS FOR | | | GUEST HOUSE PANEL. | | | 4) GUEST HOUSE MUST HAVE GFCI, WP RECEPTACLES ON BACK | | | AND FRONT. | | | 5) FOR MAIN HOUSE PLEASE PROVIDE ARC-FAULT AND GFI | | | PROTECTION AS PER FBC RE E3902. | | | 6) FOR MAIN HOUSE PLEASE PROVIDE TAMPER RESISTANT | | | RECEPTACLE AS PER FBC RE E4002.14 | | | 7) PLEASE SHOW WIRING METHOD UTILIZED TO FEED GUEST | | | HOUSE. UNDERGROUND INSTALLATION MUST COMPLY WITH NEC | | | TABLE 300.5 | | | 8) FOR GUEST HOUSE (DETACHED STRUCTURE) PLEASE SHOW | | | COMPLIANCE WITH NEC 250.32 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-16 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2020-11-16 16:44:06 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-17 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-03 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-05-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-05-24 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-04-20 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-12-15 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-05 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-13 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-28 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2021-07-12 11:19:07 | RECEIPT - MU-2021-32587 - $546.52 PAID | | 2021-06-28 15:25:39 | UPLODED IMPACT FEES QUESTIONNAIRE. EMAILED IMPACT FEE | | | OFFICE. CC |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-18 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-18 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2020-11-18 09:07:36 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-06-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-06-14 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-06-14 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-29 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-29 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2021-04-29 14:44:59 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-20110110 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS ARE FOR | | | 201 BLOOMFIELD, THE PERMIT APPLICATION IS FOR 6255 | | | WASHINGTON RD. PLEASE PRESENT MECHANICAL EQUIPMENT | | | SIZING CALCULATIONS THAT HAS THE CORRECT ADDRESS. FBC | | | 107.2.1 | | | | | | 2) PLEASE PROVIDE THE CORRECT ADDRESS ON THE PLANS. FBC | | | 107.2.1 | | | | | | 3) PLEASE SUBMIT MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS DESIGNED BY AN ENGINEER OR THE MECHANICAL | | | CONTRACTOR THAT HAS OBTAINED THE PERMIT TO INSTALL THIS | | | PROJECT. | | | A MECHANICAL SUB-PERMIT IS REQUIRED. | | | FS 471.003 (H): THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS ALONG WITH THE MECHANICAL SYSTEM DESIGN | | | MUST BE DESIGNED BY A FLORIDA LICENSED ENGINEER OR THE | | | MECHANICAL CONTRACTOR THAT HOLDS THE PERMIT FOR THE | | | SPECIFIC PROJECT WHICH HE OR SHE INSTALLS. | | | PLEASE, HAVE EITHER A LICENSED ENGINEER, PROVIDE A | | | SIGNED AND SEALED MECHANICAL EQUIPMENT SIZING | | | CALCULATION AND A SIGNED AND SEALED MECHANICAL DRAWING, | | | OR | | | THE MECHANICAL CONTRACTOR INSTALLING THE SYSTEM SHALL | | | PROVIDE THE EQUIPMENT SIZING CALCULATIONS AND A CODE | | | COMPLIANT DESIGN. CONTRACTOR SHALL INCLUDE HIS OR HER | | | PRINTED NAME AND SIGNATURE PER 2017 WPB AMENDMENTS TO | | | THE FLORIDA BUILDING CODE, CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | | | | THERE IS NO MECHANICAL SUB PERMIT FOR THIS JOB. | | | 4) PLEASE SHOW THE DRYER EXHAUST PIPING AND TERMINATION | | | LOCATION. FBC RES M1502.3 | | | | | | 5) PLEASE SHOW THE CONDENSATION LINES ON THE DRAWINGS | | | FOR EACH MECHANICAL SYSTEM AND SHOW THE TERMINATION | | | LOCATION. FBC RES M1411.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-07 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-07 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2020-11-07 07:18:46 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20110110 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR BOTH, THE | | | MAIN HOUSE AND GUEST HOUSE. FBC EC 101.5.1.1.2 | | | | | | 2) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS IN ACCORDANCE WITH MANUAL J FOR BOTH THE | | | MAIN HOUSE AND THE GUEST HOUSE. FBC RES M1401.3 | | | | | | 3) PROVIDE CODE COMPLIANT MECHANICAL PLANS FOR BOTH THE | | | MAIN HOUSE AND THE GUEST HOUSE. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2021-04-21 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-04-21 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-04-21 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2021-04-21 14:43:22 | 04/21/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-16 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2020-11-16 16:53:51 | 11/16/20 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. A SUB PLUMBING PERMIT IS REQUIRED BY A LICENSED | | | CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 105.1. | | | | | | 2. PLUMBING RISER DIAGRAM REQUIRED PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL | | | PLUMBING. | | | | | | 3. A GAS RANGE IS SHOWN ON PLANS AND NOT NOTED, A | | | SEPARATE GAS PERMIT WILL BE REQUIRED WITH A NARRATIVE | | | OF THE SCOPE OF WORK OR PROVIDE AT THIS TIME FOR REVIEW | | | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 4. THE WASHING MACHINE IS STACKABLE IN THE GUEST HOUSE | | | PLEASE SHOW THE LOCATION OF THE VALVE ACCESS, THE | | | WASHING MACHINE SHUT OFF VALVES SHALL BE ACCESSIBLE | | | WITHOUT MOVING OF THE UNITS AND WITHIN REACH PER THE | | | 2017 FBC SEC. R 2903.9.3. | | | | | | 5. THE GUEST HOUSE SHOWS A GAS WATER HEATER BUT THE | | | MAIN HOUSE DOES NOT SHOW ANY WATER HEATER PLEASE | | | CLARIFY IF THERE ARE TWO OR JUST ON THE UNIT PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 6. THIS IS MULTI-FAMILY DWELLINGS AND WATER USERS WILL | | | BE REQUIRED TO INSTALL A BACKFLOW PREVENTION ASSEMBLY | | | AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW ASSEMBLY | | | REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF HAZARD | | | POSED BY THE WATER USER. A REDUCED PRESSURE ZONE | | | BACKFLOW DEVICE WILL BE REQUIRED AT THE WATER METER PER | | | THE CITY OF WEST PALM CROSS CONNECTION CONTROL MANUAL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2021-06-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-21 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2021-06-21 11:22:13 | | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW APPROVED WITH PROVISO: | | | | | | A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF WORK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-17 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-17 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2021-06-17 16:57:58 | ****CORRECTIONS**** | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW DENIED: | | | | | | FBC B 107, PLEASE PROVIDE ROOFING INFORMATION INCLUDING | | | SYSTEM TO BE USED AND MATERIALS TO BE USED (ROOFING | | | SUB-PERMIT IS REQUIRED). |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-04 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2021-05-04 14:27:26 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC 2014 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUBMIT A ROOFING SUB-PERMIT APPLICATION AND PRODUCT | | | APPROVALS FOR ROOFING SYSTEM COMPONENTS FOR REVIEW OR A | | | PROVISO WILL BE POSTED ON PLANS FOR A SEPERATE ROOFING | | | PERMIT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | NEW COMMENT: | | | | | | 2. PRODUCT EVALUATION REPORT FOR ROOF TILE SUBMITTED | | | FOR REVIEW. PROVIDE COVER PAGE OF PRODUCT APPROVAL. | | | . PROVIDE THE FLORIDA STATE PRODUCT APPROVAL COVER | | | SHEETS FOR FL12328-R9 AND FL16709-R7; THE COVER SHEET | | | PROVIDES THE APPROVAL NUMBER, CODE VERSION, AND STATUS, | | | FBC R 301. | | | (COVER SHEETS ARE NOT REQUIRED FOR MIAMI DADE NOAS.) | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-18 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-18 |
Time |
06:16 |
Sent To |
|
|
| Notes |
| 2020-11-18 09:12:58 | PLAN REVIEW / ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC 2014 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUBMIT A ROOFING SUB-PERMIT APPLICATION AND PRODUCT | | | APPROVALS FOR ROOFING SYSTEM COMPONENTS FOR REVIEW OR A | | | PROVISO WILL BE POSTED ON PLANS FOR A SEPERATE ROOFING | | | PERMIT. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-06-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-06-17 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-06-17 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2021-05-04 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2021-05-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-18 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-18 |
Time |
06:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-05-21 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-05-21 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-05-21 |
Time |
10:41 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-12-11 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-12-11 |
Time |
12:30 |
Sent To |
I |
|
| Notes |
| 2020-12-11 13:22:51 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. ACCESSORY DWELLING UNIT NOT PERMITTED IN | | | SINGLE-FAMILY LOW DENSITY (SF7) ZONING DISTRICTS. | | | PURSUANT TO ZLDR SEC. 94-303 ACCESSORY APARTMENTS ARE | | | ONLY PERMITTED IN SINGLE-FAMILY HIGH-DENSITY (SF14) | | | RESIDENTIAL ZONING DISTRICTS. | | | | | | 2. FRONT SETBACK REQUIREMENT NOT MET. PURSUANT TO ZLDR | | | ARTICLE XIX LOT DEFINITIONS 4.A. LOT LINE, FRONT, MEANS | | | THE LINE SEPARATING A LOT FROM A STREET, ROAD OR OTHER | | | PUBLIC OR PRIVATE RIGHT-OF-WAY. AT ALL CORNER LOTS, THE | | | FRONT LOT LINE SHALL BE THE PUBLIC STREET RIGHT-OF-WAY | | | LINE WHICH POSSESSES THE NARROWEST LENGTH. THE OTHER | | | PUBLIC STREET RIGHT-OF-WAY SHALL BE CONSIDERED THE | | | CORNER LOT LINE. | | | | | | 3. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED HOME ON AN | | | ELEVATION PLAN. PURSUANT TO THE ZLDR ARTICLE XIX HEIGHT | | | OF STRUCTURE MEANS THE VERTICAL DISTANCE FROM THE | | | AVERAGE ELEVATION OF THE FINISHED GRADE OF THE | | | STRUCTURE TO THE HIGHEST PORTION OF THE STRUCTURE, | | | SUBJECT TO SPECIFIED HEIGHT REQUIREMENTS OF THIS | | | CHAPTER. FOR BUILDINGS, THE HEIGHT SHALL BE MEASURED AS | | | THE VERTICAL DISTANCE FROM THE AVERAGE ELEVATION OF THE | | | FINISHED GRADE OF THE BUILDING TO THE HIGHEST POINT OF | | | THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK | | | LINE OF A MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL | | | BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL | | | ROOFS. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|