Plan Review Details - Permit 20110052
Plan Review Stops For Permit 20110052
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2021-01-05 Cont ID  
Sent By jbrooks Date 2021-01-05 Time 13:47 Rev Time 0.00
Received By jbrooks Date 2021-01-05 Time 13:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2020-12-03 Cont ID  
Sent By jbrooks Date 2020-12-03 Time 13:46 Rev Time 0.00
Received By jbrooks Date 2020-12-03 Time 13:40 Sent To  
Notes
2020-12-03 13:47:27JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC B 107.2.1. REVISE FLOOR PLANS/BUILDING FOOTPRINT
 SHOWING LOCATION OF PROPOSED WINDOWS/DOORS TO BE
 REPLACED AND PROVIDE DIMENSIONS OF EACH OPENING.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By jbrooks Date 2020-11-05 Time 13:41 Rev Time 0.00
Received By jbrooks Date 2020-11-05 Time 12:58 Sent To  
Notes
2020-11-05 13:41:39JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC B 107.1. THE CONSTRUCTION DOCUMENTS SHALL BE
 PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE
 REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15
 FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA
 STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE.
 2. FBC B 107.2.1. PROVIDE A COMPLETE SET OF FLOOR
 PLANS/BUILDING FOOT PRINT SHOWING LOCATION OF PROPOSED
 WINDOWS/DOORS TO BE REPLACED ALONG WITH DIMENSIONS OF
 EACH OPENING; WINDOW/DOOR TYPE AND ROOM DESIGNATION.
 3. FBC B 1609. PROVIDE A COMPLETE SET OF SIGNED AND
 SEALED DESIGN PRESSURE CALCULATIONS FOR HIGH RISE
 BUILDINGS BY A FLORIDA REGISTERED DESIGN PROFESSIONAL.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-01-05 Cont ID  
Sent By jbrooks Date 2021-01-05 Time 13:47 Rev Time 0.00
Received By jbrooks Date 2021-01-02 Time 08:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-03 Cont ID  
Sent By jbrooks Date 2020-12-03 Time 13:48 Rev Time 0.00
Received By jbrooks Date 2020-12-02 Time 09:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-05 Cont ID  
Sent By jbrooks Date 2020-11-05 Time 13:41 Rev Time 0.00
Received By jbrooks Date 2020-11-04 Time 11:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2021-01-05 Cont ID  
Sent By jbrooks Date 2021-01-05 Time 13:47 Rev Time 0.00
Received By jbrooks Date 2021-01-05 Time 13:15 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-03 Cont ID  
Sent By jbrooks Date 2020-12-03 Time 13:48 Rev Time 0.00
Received By jbrooks Date 2020-12-03 Time 13:41 Sent To  
Notes
2020-12-03 06:53:46ORIGINAL PAPER DOCUMENTS ARE APPROVED AND ROUTED TO
 STORAGE. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By jbrooks Date 2020-11-05 Time 13:42 Rev Time 0.00
Received By jbrooks Date 2020-11-05 Time 12:58 Sent To  
Notes
2020-11-05 13:43:00JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM
 ALTERNATE: CONTACT PETER VALENTI (561) 805-6673
 [email protected]
  
 1ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN
 TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED
 PAPER ORIGINAL WITH A WET SIGNATURE TO:
 PETER VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6673.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved