Plan Review Details - Permit 20101326
Plan Review Stops For Permit 20101326
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-12-09 Cont ID  
Sent By rmcphers Date 2020-12-09 Time 15:42 Rev Time 0.00
Received By rmcphers Date 2020-12-09 Time 15:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-04 Cont ID  
Sent By rmcphers Date 2020-11-04 Time 13:31 Rev Time 0.00
Received By rmcphers Date 2020-11-04 Time 13:02 Sent To  
Notes
2020-11-04 13:24:35SHED
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE SET BACK DIMENSIONS FROM THE
 PROPERTY LINES AND THE EXISTING BUILDING.
  
 PLEASE PROVIDE THE FOLLOWING FOR THE "PRE FAB SHED" OR
 "SITE BUILT" WHICHEVER APPLIES -
  
 PREFAB SHED =
 1) PLEASE PROVIDE FLORIDA STATE APPROVED SHED DRAWINGS
 OR PRODUCT APPROVAL FOR THE PREFAB SHED. FBC WPB
 AMENDMENTS 107.3 EXCEPTION (1)
 2) PLEASE PROVIDE A SIGNED AND SEALED SHED TIEDOWN
 DRAWING SHOWING TIEDOWN DETAILS AND THE WIND DESIGN
 CRITERIA USED FROM AN ARCHITECT OR ENGINEER TO COMPLY
 WITH THE WIND LOADS PER FBC R301.2.1
  
 IF THIS IS A SITE BUILT SHED =
 1) THE SHED NEEDS TO MEET THE REQUIRED WIND LOADS PER
 FBC R301.2.1 - RISK CATEGORY WIND SPEED 150MPH,
 EXPOSURE "D" AND CANNOT BE CODE PRESCRIPTIVE PER FBC
 R301.2.1.1 - PLEASE PROVIDE THE SHED CONSTRUCTION
 DRAWINGS AND THE STRUCTURAL CALCULATIONS FOR THE WIND
 LOADS SHOWING THAT THE CONSTRUCTION DRAWINGS MEET THE
 REQUIRED WIND LOADS OR PROVIDE SIGNED AND SEALED
 CONSTRUCTION DETAILS FROM AN ARCHITECT OR ENGINEER.
  
 FYI = SIGNED AND SEALED DRAWINGS NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR -
 IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN
 REVIEW REQUEST FORM" EXPLAINING THE REASON FOR
 SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-28 Cont ID  
Sent By shill Date 2020-12-28 Time 12:02 Rev Time 0.00
Received By shill Date 2020-12-04 Time 14:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-24 Cont ID  
Sent By lmarchan Date 2020-11-24 Time 15:00 Rev Time 0.00
Received By lmarchan Date 2020-10-29 Time 09:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-12-04 Cont ID  
Sent By medwards Date 2020-12-04 Time 15:37 Rev Time 0.00
Received By medwards Date 2020-12-04 Time 15:37 Sent To  
Notes
2020-12-04 15:38:00ORIGINAL PAPER DOCUMENTS SIGNED AND SEAL WERE BROUGHT
 TO THE OFFICE. ROUTED TO STORAGE. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-04 Cont ID  
Sent By rmcphers Date 2020-11-04 Time 13:31 Rev Time 0.00
Received By rmcphers Date 2020-11-04 Time 13:30 Sent To  
Notes
2020-11-04 13:31:42SEE BUILDING PLAN REVIEW

Review Stop Z ZONING
Rev No 2 Status P Date 2020-12-23 Cont ID  
Sent By kalexand Date 2020-12-23 Time 08:23 Rev Time 0.00
Received By kalexand Date 2020-12-23 Time 08:23 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-11-20 Cont ID  
Sent By kalexand Date 2020-11-20 Time 18:27 Rev Time 0.00
Received By kalexand Date 2020-11-20 Time 18:27 Sent To I
Notes
2020-11-22 18:35:24ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW:
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. INDICATE THE SETBACK DIMENSIONS FROM ANY ACCESSORY
 STRUCTURE TO ALL ADJACENT PROPERTY LINES. NOTE: PER
 SECTION 94-304 OF THE ZLDR:
  
 -- ACCESSORY STRUCTURE SETBACKS ARE AS FOLLOWS:
 --FRONT: 25 FEET
 --SIDE: FIVE FEET FROM LOT LINES.
 --CORNER: SAME AS REQUIRED FOR PRINCIPAL STRUCTURE.
 --REAR: FIVE FEET MINIMUM OR 15 FEET FROM THE
 CENTERLINE OF THE ALLEY TO A GARAGE FACING THE ALLEY,
 WHICHEVER IS GREATER.
  
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1442
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved