Plan Review Details - Permit 20101294
Plan Review Stops For Permit 20101294
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 09:09 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 07:56 Sent To  
Notes
2020-11-16 09:09:44SFR REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE MINIMUM AGE OF THE CHILDREN - NEEDED
 TO DETERMINE THE OCCUPANCY CLASSIFICATION. FBC CHAPTER
 3
 2) PLEASE SHOW THE EXIT DOOR SIZE FBC1010.1.1
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-11-07 Cont ID  
Sent By fgiaquin Date 2020-11-07 Time 19:48 Rev Time 0.00
Received By fgiaquin Date 2020-11-07 Time 19:33 Sent To  
Notes
2020-11-07 19:48:19ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. EVEN THOUGH THIS IS A CHANGE OF OCCUPANCY FROM 6 TO
 12 CHILDREN THE PROPOSED SPACE MUST MEET THE CURRENT
 REQUIREMENTS OF THE ADOPTED NATIONAL ELECTRIC CODE
 (2014) PER THE FLORIDA BUILDING CODE EXISTING BUILDING
 BOOK REQUIREMENTS. PLEASE SUBMIT PLAN OF EXISTING
 ELECTRICAL IN PROPOSED SPACE AND BE AWARE IF THE PLAN
 SUBMITTED DOES NOT MEET THE CURRENT CODE IT WILL HAVE
 TO BE BROUGHT UP TO CODE. FS 471.003(2)(H); 471.025;
 WPB FBC 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By pleduc Date 2020-11-05 Time   Rev Time 0.00
Received By pleduc Date 2020-11-03 Time 15:44 Sent To  
Notes
2020-11-05 10:51:07THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THE PLAN SHEET INDICATES AN OPENING INTO AND THROUGH
 THE KITCHEN.
  
 HOW WILL CHILDREN BE CONTROLLED/SEPARATED FROM ENTERING
 THE REMAING AREA OF THE HOME?
  
 ARE YOU PROPOSING TO USE THE ENTIRE HOUSE?
  
 PLEASE PROVIDE DETAILS.
  
  
 2) THERE ARE NO INDICATIONS OF THE TYPE OF INTERIOR
 FINISHES ARE ON THE WALL, CEILING AND FLOOR.
  
 PER NFPA 101 CH 16,
  
 16.6.3.3 INTERIOR FINISH.
 16.6.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
 16.6.3.3.3 INTERIOR FLOOR FINISH.
 16.6.3.3.3.1 INTERIOR FLOOR FINISH SHALL COMPLY WITH
 SECTION 10.2.
  
 10.2.1* GENERAL.
 10.2.1.1 CLASSIFICATION OF INTERIOR FINISH MATERIALS
 SHALL BE IN
 ACCORDANCE WITH TESTS MADE UNDER CONDITIONS SIMULATING
 ACTUAL
 INSTALLATIONS, PROVIDED THAT THE AUTHORITY HAVING
 JURISDICTION IS
 PERMITTED TO ESTABLISH THE CLASSIFICATION OF ANY
 MATERIAL FOR WHICH
 CLASSIFICATION BY A STANDARD TEST IS NOT AVAILABLE,
 UNLESS OTHERWISE
 PROVIDED IN 10.2.1.2 OR 10.2.1.4.
 10.2.1.2 THE PROVISIONS OF 10.2.1.1 SHALL NOT APPLY TO
 MATERIALS HAVING
 A TOTAL THICKNESS OF LESS THAN 1?28 IN. (0.9 MM) THAT
 ARE APPLIED DIRECTLY
 TO THE SURFACE OF WALLS AND CEILINGS WHERE BOTH OF THE
 FOLLOWING
 CONDITIONS ARE MET:
 (1) THE WALL OR CEILING SURFACE IS A NONCOMBUSTIBLE OR
 LIMITEDCOMBUSTIBLE
 MATERIAL.
 (2) THE MATERIALS APPLIED MEET THE REQUIREMENTS OF
 CLASS A INTERIOR
 WALL OR CEILING FINISH WHEN TESTED IN ACCORDANCE WITH
 10.2.3,
 USING FIBER CEMENT BOARD AS THE SUBSTRATE MATERIAL.
 10.2.1.3 IF A MATERIAL HAVING A TOTAL THICKNESS OF LESS
 THAN 1?28 IN. (0.9
 MM) IS APPLIED TO A SURFACE THAT IS NOT NONCOMBUSTIBLE
 OR NOT LIMITEDCOMBUSTIBLE,
 THE PROVISIONS OF 10.2.1.1 SHALL APPLY.
  
 10.2.2.2* INTERIOR FLOOR FINISH SHALL COMPLY WITH
 10.2.7 UNDER ANY OF
 THE FOLLOWING CONDITIONS:
 (1) WHERE FLOOR FINISH REQUIREMENTS ARE SPECIFIED
 ELSEWHERE IN THE
 CODE
 (2) WHERE THE FIRE PERFORMANCE OF THE FLOOR FINISH
 CANNOT BE
 DEMONSTRATED TO BE EQUIVALENT TO FLOOR FINISHES WITH A
 CRITICAL
 RADIANT FLUX OF AT LEAST 0.1 W/CM2
  
 PLEASE PROVIDE DETAILS ON THE TYPE OF FINISHES.
  
  
 3) THERE ARE NO INDICATIONS OF SMOKE ALARMS.
  
 16.6.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 16.6.3.4.1 SMOKE ALARMS SHALL BE INSTALLED WITHIN
 DAY-CARE HOMES
 IN ACCORDANCE WITH 9.6.2.10.
  
 NFPA 101, CH 9
 9.6.2.10 SMOKE ALARMS.
 9.6.2.10.1 WHERE REQUIRED BY ANOTHER SECTION OF THIS
 CODE, SINGLESTATION
 AND MULTIPLE-STATION SMOKE ALARMS SHALL BE IN
 ACCORDANCE
 WITH NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE,
 UNLESS
 OTHERWISE PROVIDED IN 9.6.2.10.3, 9.6.2.10.4,
 9.6.2.10.5, OR
 9.6.2.10.6.
  
 NFPA 72, CH 29
  
 29.5.1* REQUIRED DETECTION.
 29.5.1.1* WHERE REQUIRED BY OTHER GOVERNING LAWS,
 CODES, OR
 STANDARDS FOR A SPECIFIC TYPE OF OCCUPANCY, APPROVED
 SINGLEAND
 MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED AS
 FOLLOWS:
 (1)*IN ALL SLEEPING ROOMS AND GUEST ROOMS
 (2)*OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING
 AREA,
 WITHIN 21 FT (6.4 M) OF ANY DOOR TO A SLEEPING ROOM,
 WITH
 THE DISTANCE MEASURED ALONG A PATH OF TRAVEL
 (3) ON EVERY LEVEL OF A DWELLING UNIT, INCLUDING
 BASEMENTS
 (4) ON EVERY LEVEL OF A RESIDENTIAL BOARD AND CARE
 OCCUPANCY
 (SMALL FACILITY), INCLUDING BASEMENTS AND EXCLUDING
 CRAWL
 SPACES AND UNFINISHED ATTICS
 (5)*IN THE LIVING AREA(S) OF A GUEST SUITE
 (6) IN THE LIVING AREA(S) OF A RESIDENTIAL BOARD AND
 CARE OCCUPANCY
 (SMALL FACILITY)
  
 PLEASE PROVIDE DETAILS ON SA LOCATIONS.
  
  
 4) HOW WILL THE PROPOSED ROOM BE USED FOR?
  
 16.6.3.4.3 SINGLE-STATION OR MULTIPLE-STATION SMOKE
 ALARMS OR
 SMOKE DETECTORS SHALL BE PROVIDED IN ALL ROOMS USED FOR
 SLEEPING
 IN ACCORDANCE WITH 9.6.2.10.
  
 IF THE ROOM WILL BE USED FOR SLEEPING/NAPPING PLEASE
 PROVIDE A SA.
  
 PLEASE PROVIDE DETAILS.
  
 5) THERE ARE NO INDICATIONS OF LIGHTING ALONG THE PATH
 OF EXITING.
  
 16.6.2.8 ILLUMINATION OF MEANS OF EGRESS. MEANS OF
 EGRESS SHALL
 BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8.
  
 7.8 ILLUMINATION OF MEANS OF EGRESS.
 7.8.1 GENERAL.
 7.8.1.1* ILLUMINATION OF MEANS OF EGRESS SHALL BE
 PROVIDED IN
 ACCORDANCE WITH SECTION 7.8 FOR EVERY BUILDING AND
 STRUCTURE WHERE
 REQUIRED IN CHAPTERS 11 THROUGH 43. FOR THE PURPOSES OF
 THIS
 REQUIREMENT, EXIT ACCESS SHALL INCLUDE ONLY DESIGNATED
 STAIRS, AISLES,
 CORRIDORS, RAMPS, ESCALATORS, AND PASSAGEWAYS LEADING
 TO AN EXIT. FOR THE
 PURPOSES OF THIS REQUIREMENT, EXIT DISCHARGE SHALL
 INCLUDE ONLY
 DESIGNATED STAIRS, AISLES, CORRIDORS, RAMPS,
 ESCALATORS, WALKWAYS, AND EXIT
 PASSAGEWAYS LEADING TO A PUBLIC WAY.
  
 7.8.2 SOURCES OF ILLUMINATION.
 7.8.2.1 ILLUMINATION OF MEANS OF EGRESS SHALL BE FROM A
 SOURCE
 CONSIDERED RELIABLE BY THE AUTHORITY HAVING
 JURISDICTION.
 7.8.2.2 BATTERY-OPERATED ELECTRIC LIGHTS AND OTHER
 TYPES OF PORTABLE LAMPS
 OR LANTERNS SHALL NOT BE USED FOR PRIMARY ILLUMINATION
 OF MEANS OF EGRESS.
 BATTERY-OPERATED ELECTRIC LIGHTS SHALL BE PERMITTED TO
 BE USED AS AN
 EMERGENCY SOURCE TO THE EXTENT PERMITTED UNDER SECTION
 7.9.
  
 PLEASE PROVIDE LIGHTING DETAILS.
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 09:11 Rev Time 0.00
Received By rmcphers Date 2020-10-27 Time 08:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 09:10 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 09:10 Sent To  
Notes
2020-11-16 09:11:02PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-11-03 Cont ID  
Sent By medwards Date 2020-11-03 Time 13:51 Rev Time 0.00
Received By medwards Date 2020-11-03 Time 13:27 Sent To  
Notes
2020-11-03 13:51:381ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20101294
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MORE INFORMATION, WHAT ARE THE AGES
 OF THE CHILDREN? HOW MANY ROOMS WILL BE USED FOR THE
 DAYCARE? PLEASE SHOW CALCULATIONS SHOWING THE EXISTING
 A/C WILL HANDLE THE ADDITIONAL LOAD OF PEOPLE. FBC
 107.2
  
 2) PLEASE SHOW THE REQUIRED OUTDOOR AIR CALCULATIONS
 FOR THE ROOMS USED FOR THIS DAYCARE. FBC M TABLE
 403.3.1.1
  
 3) PLEASE SHOW HOW THE OUTDOOR AIR WILL BE DUCTED INTO
 THE MECHANICAL SYSTEM. FBC M 601
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-11-03 Cont ID  
Sent By ccole Date 2020-11-03 Time 12:52 Rev Time 0.00
Received By ccole Date 2020-11-03 Time 12:12 Sent To  
Notes
2020-11-03 12:53:341ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20101294
 11/3/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE ARE NO PLUMBING PLANS TO REVIEW HOWEVER SINCE
 THIS IS A CHANGE OF OCCUPANCY TO A DAYCARE COMPLIANCE
 WITH SECTION 1010. FBC-17 EXISTING BUILDING CODE FOR
 INCREASED PLUMBING FIXTURES MAY BE REQUIRED. THE
 SUBMITTED FLOOR PLAN DOES NOT PROVIDE SUFFICIENT
 INFORMATION TO DETERMINE THE OCCUPANCY CLASSIFICATION
 OF THE FACILITY AND WHAT FIXTURES ARE REQUIRED PER
 TABLE 403.3 FBC-P. PLEASE REVIEW SECTION 1010 ( PRINTED
 BELOW). AND SECTION 305.2 GROUP E, DAY CARE FACILITIES
 FBC B.
  
 SECTION 1010: WHERE THE OCCUPANCY OF AN EXISTING
 BUILDING OR PART OF AN EXISTING BUILDING IS CHANGED
 SUCH THAT THE NEW OCCUPANCY IS SUBJECT TO INCREASED OR
 DIFFERENT PLUMBING FIXTURE REQUIREMENTS OR TO INCREASED
 WATER SUPPLY REQUIREMENTS IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE, PLUMBING, THE NEW OCCUPANCY
 SHALL COMPLY WITH THE INTENT OF THE RESPECTIVE FLORIDA
 BUILDING CODE, PLUMBING PROVISIONS.
  
 IF IT IS DETERMINE THAT THE THE DAYCARE IS CLASSIFIED
 AS AN EDUCATIONAL (E) OCCUPANCY PLEASE SEE TABLE 403.3
 FBC-17 PLUMBING AND PROVIDE PLUMBING FIXTURE
 CALCULATIONS. INDICATE ON THE PLAN THE REQUIRED AND
 PROVIDED PLUMBING FIXTURES FOR THE PROPOSED OCCUPANCY.
 PLEASE NOTE THAT SANITARY AND WATER RISER DRAWINGS WILL
 BE REQUIRED FOR NEW FIXTURE INSTALLATIONS- SECTION
 107.3.5.1.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-16 Cont ID  
Sent By rmcphers Date 2020-11-16 Time 09:11 Rev Time 0.00
Received By rmcphers Date 2020-11-16 Time 09:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2020-11-05 Cont ID  
Sent By awooten Date 2020-11-05 Time   Rev Time  
Received By awooten Date 2020-11-05 Time   Sent To  
Notes
2020-11-05 10:11:25**************************ZONING REVIEW
 FAILED**************************
  
 PROVIDE APPROVAL FROM THE STATE TO INCREASE TO12
 CHILDREN.
  
 UPDATE YOUR BUSINESS TAX RECEIPT TO INDICATE THE
 INCREASE (UP TO 12).
  
 ALANA WOOTEN
 PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]