Plan Review Details - Permit 20101027
Plan Review Stops For Permit 20101027
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2020-10-22 Cont ID  
Sent By cpuell Date 2020-10-22 Time 12:27 Rev Time 0.00
Received By cpuell Date 2020-10-22 Time 12:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-01-08 Cont ID  
Sent By medwards Date 2021-01-08 Time 07:12 Rev Time 0.00
Received By medwards Date 2020-12-10 Time 16:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 11:31 Rev Time 0.00
Received By medwards Date 2020-10-22 Time 07:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2021-01-08 Cont ID  
Sent By medwards Date 2021-01-08 Time 07:11 Rev Time 0.00
Received By medwards Date 2021-01-08 Time 06:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 11:30 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 10:59 Sent To  
Notes
2020-10-27 11:31:181ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20101027
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE REFRIGERATION DETAILS FOR THE WALK IN
 COOLER AND FREEZER INCLUDING THE CONDENSING UNITS AND
 LOCATIONS. FBC 107.2
  
 2) PLEASE PROVIDE SYSTEM REQUIREMENT DETAILS BASED ON
 FBC M 1102.1
  
 THE SYSTEM CLASSIFICATION, ALLOWABLE REFRIGERANTS,
 MAXIMUM QUANTITY, ENCLOSURE REQUIREMENTS, LOCATION
 LIMITATIONS, AND FIELD PRESSURE TEST REQUIREMENTS SHALL
 BE DETERMINED AS FOLLOWS:
 1. 1.DETERMINE THE REFRIGERATION SYSTEM'S
 CLASSIFICATION, IN ACCORDANCE WITH SECTION 1103.3.
 2. 2.DETERMINE THE REFRIGERANT CLASSIFICATION IN
 ACCORDANCE WITH SECTION 1103.1.
 3. 3.DETERMINE THE MAXIMUM ALLOWABLE QUANTITY OF
 REFRIGERANT IN ACCORDANCE WITH SECTION 1104, BASED ON
 TYPE OF REFRIGERANT, SYSTEM CLASSIFICATION AND
 OCCUPANCY.
 4. 4.DETERMINE THE SYSTEM ENCLOSURE REQUIREMENTS IN
 ACCORDANCE WITH SECTION 1104.
 5. 5.REFRIGERATION EQUIPMENT AND APPLIANCE LOCATION AND
 INSTALLATION SHALL BE SUBJECT TO THE LIMITATIONS OF
 CHAPTER 3.
 6. 6.NONFACTORY-TESTED, FIELD-ERECTED EQUIPMENT AND
 APPLIANCES SHALL BE PRESSURE TESTED IN ACCORDANCE WITH
 SECTION 1108.
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 11:31 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 11:31 Sent To  
Notes
***NONE***