| Plan Review Stops For Permit 20100914 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-22 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-22 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-06 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-06 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-06 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-06 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-28 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-28 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2020-12-28 09:52:10 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | | | | ELECTRICAL REVIEW STATUS: FAILED, SEE COMMENTS BELOW. | | | | | | 1) SUB ELECTRICAL PERMIT IS REQUIRED WITH SPECIFIC | | | SCOPE OF WORK. FBC 107 | | | 2) PLEASE SHOW LOCATION OF PANEL 1LD1 FBC 107 | | | 3) SPECIFY SIZE OF CONDUCTOR, BREAKER FOR MOTORIZED | | | GATE FBC 107 | | | 4) SPECIFY UNDERGROUND INSTALLATION METHOD FOR | | | MOTORIZED GATE CIRCUIRT AS PER NEC 300.5 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-12-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-12-15 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2020-12-15 09:56:29 | FIRE PROVISO: | | | | | | THE OPERATION OF RELEASING THE GATE LATCH FOR EXITING | | | MUST BE OBVIOUS | | | AND ACCESSIBLE WITHOUT ANY SPECIAL KNOWLEDGE | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-10-22 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2020-10-22 16:25:34 | FIRE PROVISO: | | | | | | THE OPERATION OF RELEASING THE GATE LATCH FOR EXITING | | | MUST BE OBVIOUS | | | AND ACCESSIBLE WITHOUT ANY SPECIAL KNOWLEDGE | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-01-07 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-07 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-06 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-28 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-14 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-06 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-21 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-12-28 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-28 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-28 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-06 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-06 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-12-21 |
Time |
16:44 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-12-21 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-11-05 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2020-12-17 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2020-11-05 10:57:37 | FAILED | | | | | | 1) PROVIDE A COPY OF THE ABSTRACTED/ALTA SURVEY FOR | | | THIS PORTION OF THE SITE SHOWING THE EASEMENTS IN THE | | | AREA. | | | | | | A. IF THE SURVEY SHOWS THE WALL/FENCING WITHIN ANY | | | PUBLIC UTILITY EASEMENTS, THEN YOU MUST PROVIDE | | | EASEMENT CONSENT LETTERS FROM THE PUBLIC UTILITY | | | PROVIDERS WHO ARE PERMITTED WITHIN THE EASEMENT. IF | | | THERE IS NO EASEMENT ENCROACHMENT, THEN NO LETTERS ARE | | | REQUIRED. | | | B. PROVIDE AN EASEMENT CONSENT LETTER FROM THE CITY'S | | | WATER UTILITY DIVISION. | | | | | | 2) HIGHLIGHT THE PROPOSED FENCING ON THE SITE VIEW | | | SHEET PROVIDED BY WALKER DESIGN AND CONSTRUCTION. | | | | | | 3) IT APPEARS THAT THERE IS MORE FENCING INDICATED AS | | | BEING INSTALLED ON THE UDS SITE PLAN THAN THE WALKER | | | DESIGN SITE PLAN. PLEASE EXPLAIN. | | | | | | 4) PROVIDE THE HEIGHT OF THE DECORATIVE BALL FEATURES | | | THAT ARE MOUNTED ON THE FENCE POSTS. THESE FEATURES MAY | | | ONLY EXCEED THE PERMITTED FENCE HEIGHT OF SIX (6) FEET | | | BY A MAXIMUM OF 10%. NOTE: THIS COMMENT ONLY APPLIES TO | | | FENCES AND GATES WITHIN THE REQUIRED SETBACKS. | | | | | | 5) THERE ARE TWO VERSIONS OF THE SHOP DRAWING COVER | | | SHEET UPLOADED. THE SINGLE SHEET THAT IS UPLOADED IN | | | THE "DRAWINGS" FOLDER SHOWS THE COLOR AS BRONZE WHILE | | | THE UPLOAD TO THE "SUPPORTING DOCUMENTS" FOLDER HAS THE | | | BRONZE COLOR CROSSED OUT AND REPLACED BY BLACK. ALL | | | PLAN SUBMITTALS MUST AGREE. | | | | | | 6) PROVIDE DETAILS OF THE "SECURITY MESH" THAT IS | | | REFERENCED ON SOME OF THE SHOP DRAWING SHEETS. | | | ADDITIONALLY, NOT ALL THE IDENTICAL BASE SHEETS | | | REFERENCE THE SECURITY MESH. ALL PLAN SUBMITTALS MUST | | | AGREE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|