Plan Review Details - Permit 20100912
| Plan Review Stops For Permit 20100912 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-12-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-07 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-07 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-30 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-07 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2020-10-30 10:05:52 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE HORIZONTAL SLIDING WIDOWS WITH THE DESIGN | | | PRESSURES OF +/- 40 PSF DO NOT APPEAR TO MEET THE | | | WINDLOAD PRESSURES THAT ARE REQUIRED FOR THE OPENINGS. | | | THIS IS A TWO STOREY STRUCTURE WITH A MEAN ROOF HEIGHT | | | OF AROUND 24 FEET. THE WIND SPEED IS 170 MPH VULT. THE | | | DEFAULT EXPOSURE CATEGORY IS "EXPOSURE C". IT IS NOT | | | SPECIFIED WHICH WALL ZONE THE WINDOWS ARE LOCATED IN. | | | THE LARGEST OF THESE WINDOWS HAS AN AREA OF LESS THAN | | | 20 SQFT. THE REQUIRED DESIGN PRESSURES IN ZONE 4 | | | (INTERIOR) FOR A 20SQFT TRIBURARY AREA IS +39.8, -43.4 | | | PSF. THE PRESSURES ARE GREATER IN WALL ZONE 5 (CORNER) | | | AND FOR THE SMALLER WINDOWS. SUBMIT PRODUCT APPROVALS | | | FOR WINDOWS THAT HAVE ADEQUATE DESIGN PRESSURES. | | | | | | 2) SOME OF THE WINDOWS ARE NOT IMPACT RESISTANT. ARE | | | THERE EXISTING PERMITTED AND APPROVED IMPACT PROTECTION | | | DEVICES? SHOW HOW THE REQUIREMENTS OF FBC EXISTING | | | BUILDINGS 707.4 REPLACEMENT OF WINDOWS AND DOORS WILL | | | BE MET. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-07 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-19 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-05 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-29 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-10-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-30 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-30 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
|