| Plan Review Stops For Permit 20100902 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-14 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-14 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-25 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-25 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2020-11-25 12:33:07 | NEW BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING | | | THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | | PROPOSED WATER RETAINING SWALES) | | | 2) PLEASE DESCRIBE THE BUILDING USE. (WHAT IS THE | | | BUILDING BEING USED FOR?). | | | 3) EACH PAGE OF THE DRAWINGS NEED TO BE SIGNED AND | | | SEALED BY THE ENGINEER. FBC 107.2 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-15 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-15 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-12-02 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-02 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-02 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2020-12-02 08:39:42 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: FAILED. | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SHOW LOCATION OF NEW SERVICE, PANEL. PROVIDE | | | RISER DIAGRAM SHOWING PANEL SIZE, MAIND DISCONNECT, | | | SERVICE CONDUCTOR SIZE, AND GROUNDING DETAILS. | | | 2) DRAWINGS WILL NEED TO BE SIGNED BY CONTRACTOR | | | QUALIFIER OR ENGINEER. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-15 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-01-06 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-01-05 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-13 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-19 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-19 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-20 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-20 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2020-11-20 12:05:44 | NO PLUMBING ON THE SCOPE OF WORK OR ON PLANS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-25 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-25 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-01-14 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-01-14 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-25 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-25 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2020-11-25 12:39:09 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-08 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-01-08 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-01-08 |
Time |
17:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-01-04 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-01-04 |
Time |
16:54 |
Sent To |
I |
|
| Notes |
| 2021-01-04 17:08:26 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PROVIDE A CURRENT PROPERTY SURVEY INDICATIONG THE | | | FOLLWING: | | | -- LOCATION OF WORK | | | -- SETBACKS DIMENSIONS OF PROPOSED WORK FROM ALL | | | PROPERTY LINES; PURSUANT TO ZLDR SEC. 94-304, THE | | | SETBACKS FOR ACCESSORY STRUCTURES ARE AS FOLLOWS: | | | --FRONT: 25 FEET | | | --SIDE: FIVE FEET MINIMUM | | | --REAR: 15 FEET OR 15 FEET FROM THE CENTERLINE OF THE | | | ALLEY TO A GARAGE DOOR FACING THE ALLEY, WHICHEVER IS | | | GREATER. | | | | | | 2. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED STRUCTURE | | | ON THE ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION | | | 94-611, HEIGHT SHALL BE MEASURED AS THE VERTICAL | | | DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED | | | GRADE OF THE BUILDING TO THE HIGHEST POINT OF THE TOP | | | OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK LINE OF | | | A MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL BETWEEN | | | EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|