| Plan Review Stops For Permit 20100763 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-26 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-23 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-23 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2020-11-23 11:24:10 | SHUTTER FOR GARAGE ENTRY DOOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) SHUTTER DRAWINGS PROVIDED DO NOT MEET THE REQUIRED | | | WIND PRESSURES (-180 AND +90) PROVIDED. | | | 2) PLEASE PROVIDE THE FRONT PAGES FOR THE PROVIDED | | | SHUTTER PRODUCT APPROVAL (MIAMI DADE OR FLORIDA STATE). | | | FRONT PAGES ARE REQUIRED TO DETERMINE IF THE PRODUCT | | | APPROVAL IS APPROVED BY MIAMI DADE OR FLORIDA STATE. | | | 3) WIND PRESSURES PROVIDED NEED TO BE SIGNED AND SEALED | | | BY THE ARCHITECT OR ENGINEER. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2020-11-02 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-02 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2020-11-02 10:41:09 | SHUTTER FOR GARAGE ENTRY DOOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE SIGNED AND SEALED WIND DESIGN | | | PRESSURES FOR THE OPENING FROM THE ARCHITECT OR | | | ENGINEER. FBC 1609 | | | 2) PLEASE PROVIDE THE FRONT PAGES FOR THE PROVIDED | | | SHUTTER PRODUCT APPROVAL (MIAMI DADE OR FLORIDA STATE). | | | 3) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | WHERE THE SHUTTER IS TO BE INSTALLED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2020-10-21 13:37:58 | SHUTTER FOR GARAGE ENTRY DOOR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE SIGNED AND SEALED WIND DESIGN | | | PRESSURES FOR THE OPENING FROM THE ARCHITECT OR | | | ENGINEER. FBC 1609 | | | 2) PLEASE PROVIDE THE FRONT PAGES FOR THE PROVIDED | | | SHUTTER PRODUCT APPROVAL (MIAMI DADE OR FLORIDA STATE). | | | 3) PLEASE PROVIDE A FLOOR PLAN SHOWING THE LOCATION OF | | | WHERE THE SHUTTER IS TO BE INSTALLED. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-10 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-23 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-18 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-02 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-26 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-16 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-05-26 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-05-26 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-11-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-23 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-23 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2020-11-23 11:24:43 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-21 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-21 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|