| Plan Review Stops For Permit 20100734 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-21 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-21 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-01-21 10:57:28 | MASTER FOR 3626, 3620, 3608 & 3602 VILLAGE BLVD |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-11 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-12-11 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2020-12-11 15:11:07 | HAVE WORKED WITH DEVELOPER ON ADDRESSES, BUT WAS ASKED | | | TO HOLD OFF UNTIL THEY OWNED THE PROPERTY. PLEASE | | | CONTACT [email protected] TO CONFIRM ADDRESSES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-23 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-23 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2021-03-26 12:19:15 | PROVISO ? | | | | | | SUBMIT A BUILDING UNDER CONSTRUCTION ELEVATION | | | CERTIFICATE TO PLAN REVIEW, REQUIRED JUST AFTER | | | FINISHED FLOOR IS POURED | | | | | | SUBMIT A FINISHED CONSTRUCTION ELEVATION CERTIFICATE TO | | | PLAN REVIEW, REQUIRED AFTER FINISHED GRADE AND ALL | | | MECHANICAL EQUIPMENT IS SET, BEFORE FINAL INSPECTION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-19 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-19 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2021-03-19 08:59:55 | NEW 4 STORY APARTMENT BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) STRAPPING IS NOT SHOWN FOR "TOWER TRUSS LAYOUT A,B | | | AND C" - DRAWING (S-2.1.6) HAS A STRAP CONNECTOR | | | SCHEDULE - THE TRUSS FRAMING PLAN NEEDS TO SHOW THE | | | LOCATION OF THE TRUSS CONNECTORS (STRAPPING). | | | | | | | | | | | | | | | | | | | | 2021-03-15 09:00:12 | PERMIT FEE REVISED BASED ON 56294 SQ. FT. X ICC | | | VALUATION 130.52 PER SQ.FT. = 7,347,492.00 JOB VALUE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-03 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2021-02-04 09:16:11 | NEW 4 STORY APARTMENT BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) I DID NOT CATCH THIS ON THE FIRST REVIEW - ALL UNIT | | | DOORS - PLEASE SHOW THE REQUIRED MANEUVERING SPACE (18" | | | BESIDE THE DOOR) TO EXIT THE UNIT OR ROOM. FBC | | | ACCESSIBILITY FHA REQUIREMENT ANSI 4.13.6 | | | 2) I DID NOT CATCH THIS ON THE FIRST REVIEW - UNIT B1 | | | DISTANCE FROM THE KITCHEN ISLAND TO THE DISHWASHER | | | NEEDS TO BE MIN. 40" - USABLE KITCHENS WOULD MEET | | | SECTION 100.205(C)(3)(IV) IF:(B)CLEARANCE BETWEEN | | | COUNTERS AND ALL OPPOSING BASE CABINETS, COUNTERTOPS, | | | APPLIANCES OR WALLS IS AT LEAST 40 INCHES. | | | 3) WE ARE REQUIRING THAT YOU SHOW THE CLEAR FLOOR SPACE | | | FOR THE PLUMBING FIXTURES ON EACH UNIT FLOOR PLAN TO | | | SHOW THAT EACH UNIT COMPLIES WITH FAIR HOUSING | | | ACCESSIBILITY REQUIREMENTS. | | | 4) DRAWING (S-2.1.6) HAS A STRAP CONNECTOR SCHEDULE - | | | THE TRUSS FRAMING PLAN NEEDS TO SHOW THE LOCATION OF | | | THE TRUSS CONNECTORS (STRAPPING). | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-06 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-04 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2020-11-06 10:52:52 | NEW 4 STORY APARTMENT BUILDING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) SURVEY PROVIDED SHOWS FLOOD ZONE "ABE" WHAT IS THAT? | | | 2) SURVEY PROVIDED NEEDS TO BE ELECTRONICALLY/DIGITALLY | | | SIGNED BY THE SURVEYOR FOR USE IN PROJECTDOX. | | | 3) PLEASE SHOW ELEVATOR SIZE TO COMPLY WITH FBC 3002.4 | | | ELEVATOR CAR TO ACCOMMODATE AMBULANCE STRETCHER. | | | 4) DRAWING (LS-0.1.0) SHOWS BUILDING CONSTRUCTION TYPE | | | IIIB UNDER "PROJECT NARRATIVE" AND IB UNDER | | | "CONSTRUCTION TYPE" PLEASE CLARIFY (CONSTRUCTION TYPE 1 | | | WOULD NEED TO SHOW ALL ROOF FRAMING AND SHEATHING TO BE | | | FIRE RETARDANT PER FBC CHAPTER 6). | | | 5) DRAWING (LS-0.1.0) SHOULD ALSO SHOW THE HORIZONTAL | | | FIRE SEPARATION REQUIREMENT PER FBC 420.3 | | | 6) ACCESSIBILITY UNIT PLANS - MASTER BATH - PLEASE SHOW | | | THE REQUIRED CLEAR FLOOR SPACE FOR THE DOORS THAT OPEN | | | INTO THE BATHROOM FBC ACCESSIBILITY FHA REQUIREMENT 7 | | | (2)(B). | | | 7) DRAWING (S-6.1.1) SHOWS PER 2014 FBC - SHOULD BE | | | 2017 FBC. | | | 8) PLEASE SHOW THE UNIT DOOR NUMBER 1 ON THE DOOR | | | SCHEDULE TO BE SELF-LATCHING AND CLOSING PER FBC | | | 716.5.9 | | | 9) PLEASE SHOW THE SQUARE FOOTAGE OF THE BUILDING - PER | | | FLOOR - TOTAL. | | | 10) DRAWING (A-2.1.3) PLEASE POINT OUT THE REQUIRED | | | ROOF OVERFLOW SCUPPER LOCATIONS FBC 1503.4.1 | | | 11) SOIL REPORT PROVIDED NEEDS TO BE | | | ELECTRONICALLY/DIGITALLY SIGNED BY THE ENGINEER. SOIL | | | REPORT IS BASED ON A 3-STORY BUILD IS THIS OK WITH YOU? | | | 12) DRAWING (A-10.1.2) IN THE "LEGEND FOR WALL | | | REINFORCING" SAYS TO SEE DRAWING (A-10.4) THAT DRAWING | | | IS NOT UPLOADED TO PROJECTDOX. | | | 13) A "THRESHOLD/SPECIAL INSPECTOR AGREEMENT OF | | | UNDERSTANDING" FORM WILL NEED TO BE FILLED OUT - PLEASE | | | SEND AN EMAIL TO [email protected] AND ASK FOR "THE | | | GUIDELINES AND POLICIES FOR THRESHOLD AND SPECIAL | | | INSPECTORS" | | | 14) PLEASE PROVIDE A COPY OF THE FLOOR/CEILING SOUND | | | TRANSMISSION REPORTS (IIC AND STC) AS NOTED ON THE | | | DRAWINGS? - FBC1207 | | | 15) DRAWING (S-2.1.6) HAS A STRAP CONNECTOR SCHEDULE - | | | THE PLAN NEEDS TO SHOW THE LOCATION OF THE TRUSS | | | CONNECTORS (STRAPPING). | | | 16) SEPARATE PERMITS AND REVIEWS ARE REQUIRED FOR - | | | GAZEBOS, PARKING LOT, DUMPSTER ENCLOSURE, FENCE - | | | PLEASE ACKNOWLEDGE THIS ON THE DRAWINGS. | | | 17) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. | | | AMENDMENT 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH | | | ARE REQUIRED TO BE SIGNED AND SEALED BY THE ARCHITECT | | | OR ENGINEER OF RECORD SHALL CONTAIN A STATEMENT THAT, | | | TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S KNOWLEDGE, | | | THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE | | | MINIMUM BUILDING CODES AND THE APPLICABLE FIRE-SAFETY | | | STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND CHAPTER 633 FLORIDA | | | STATUTES. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-22 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-22 |
Time |
12:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-01-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-29 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-29 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2021-01-29 16:30:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-3.1.1 | | | | | | 1) COMPLETED | | | | | | 2) COMPLETED | | | | | | 3) COMPLETED | | | | | | | | | PAGE E-4.1.0 | | | | | | 1) NOTE #3 TO PANEL NOTES REFERENCES ROMEX IT IS NOT | | | ALLOWED IN A TYPE 1 B BUILDING. 334.10 (5) UNLESS | | | INSTALLED IN CONDUIT. | | | | | | GENERAL NOTES | | | | | | FIRE ALARM, BDA, SITE LIGHTING, LOW VOLTAGE WORK | | | REQUIRES SEPARATE PERMITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-05 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-11-04 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2020-11-05 16:11:22 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-3.1.1 | | | | | | 1) HOUSE SERVICE SHOWS ONE SET OF 250 AL FOR 400A | | | | | | 2) AIC RATING OF SERVICE AND PANELS REQUIRED PER 110.9, | | | 110,10 | | | | | | 3) MAIN #2 1400A REQUIRES COMPLIANCE WITH 240.87(A)(B) | | | PLEASE INDICATE METHOD TO BE USED. | | | | | | | | | PAGE E-4.1.0 | | | | | | 1) NOTE #3 TO PANEL NOTES REFERENCES ROMEX IT IS NOT | | | ASLLOWED IN A TYPE 1 B BUILDING. 334.10 (5) UNLESS | | | INSTALLED IN CONDUIT. | | | | | | GENERAL NOTES | | | | | | FIRE ALARM, BDA, SITE LIGHTING, LOW VOLTAGE WORK | | | REQUIRES SEPARATE PERMITS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-11-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2020-11-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-05 08:16:05 | ONSITE UTILITIES ARE PRIVATE. REVIEWING OVERALL | | | ENGINEERING SUBMITTAL E20080018. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-03-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-15 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2021-03-15 15:24:08 | FIRE PROVISO: | | | | | | 1) ALL UNDERGROUND FIRE LINES SHALL BE INSTALLED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS PER NFPA 24 | | | | | | | | | 2) PER NFPA 101 CH 8 | | | | | | 8.6.11 CONCEALED SPACES AND DRAFTSTOPS. | | | 8.6.11.1 ANY CONCEALED COMBUSTIBLE SPACE IN WHICH | | | BUILDING | | | MATERIALS HAVING A FLAME SPREAD INDEX GREATER THAN | | | CLASS A ARE | | | EXPOSED SHALL BE DRAFTSTOPPED AS FOLLOWS: | | | | | | (2) EVERY UNOCCUPIED ATTIC SPACE SHALL BE SUBDIVIDED BY | | | DRAFTSTOPS | | | INTO AREAS NOT TO EXCEED 3000 FT2 (280 M2). | | | | | | REVIEW AND INSTALL AS APPLICABLE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-01-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-01-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-01-22 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2021-01-22 13:19:40 | FIRE PROVISO: | | | | | | 1) ALL UNDERGROUND FIRE LINES SHALL BE INSTALLED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS PER NFPA 24 | | | | | | | | | 2) PER NFPA 101 CH 8 | | | | | | 8.6.11 CONCEALED SPACES AND DRAFTSTOPS. | | | 8.6.11.1 ANY CONCEALED COMBUSTIBLE SPACE IN WHICH | | | BUILDING | | | MATERIALS HAVING A FLAME SPREAD INDEX GREATER THAN | | | CLASS A ARE | | | EXPOSED SHALL BE DRAFTSTOPPED AS FOLLOWS: | | | | | | (2) EVERY UNOCCUPIED ATTIC SPACE SHALL BE SUBDIVIDED BY | | | DRAFTSTOPS | | | INTO AREAS NOT TO EXCEED 3000 FT2 (280 M2). | | | | | | REVIEW AND INSTALL AS APPLICABLE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-11-18 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2020-11-18 12:23:48 | FIRE PROVISO: | | | | | | 1) ALL UNDERGROUND FIRE LINES SHALL BE INSTALLED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS PER NFPA 24 | | | | | | | | | 2) PER NFPA 101 CH 8 | | | | | | 8.6.11 CONCEALED SPACES AND DRAFTSTOPS. | | | 8.6.11.1 ANY CONCEALED COMBUSTIBLE SPACE IN WHICH | | | BUILDING | | | MATERIALS HAVING A FLAME SPREAD INDEX GREATER THAN | | | CLASS A ARE | | | EXPOSED SHALL BE DRAFTSTOPPED AS FOLLOWS: | | | | | | (2) EVERY UNOCCUPIED ATTIC SPACE SHALL BE SUBDIVIDED BY | | | DRAFTSTOPS | | | INTO AREAS NOT TO EXCEED 3000 FT2 (280 M2). | | | | | | REVIEW AND INSTALL AS APPLICABLE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-26 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-03-26 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-03-12 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-25 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-01-20 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-11 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-23 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-19 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-02-19 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2021-03-19 08:41:29 | RECEIPT - MU-2021-8958 - $1,904,992.80 - PAID | | 2021-02-19 14:06:19 | 2/19/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-06 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-06 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2020-11-06 11:09:31 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-23 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-23 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-25 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-25 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-02 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2020-11-02 10:38:59 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100734 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SHOW THAT ALL INTAKE OPENINGS MEET FBC M | | | 401.4 | | | | | | 2) PLEASE SHOW THAT ALL EXHAUST OUTLET LOCATIONS MEET | | | FBC M 501.3.1 | | | | | | 3) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR NATURAL | | | VENTILATION BASED ON FBC M 402 | | | | | | 4) SHEET M-4.1.1 NOTE 9 INDICATES A X VENT OUTSIDE AIR | | | INTAKE, PLEASE PROVIDE SPECIFICATIONS FOR THIS AIR | | | INTAKE. FBC M 401.5 | | | | | | 5) PLEASE PROVIDE A LETTER FROM THE DRYER MANUFACTURER | | | STATING THAT THE X VENT DRYER EXHAUST TERMINATION IS | | | ALLOWED WITH THEIR DRYER. THE X VENT IS UNIQUE IN THE | | | FACT THAT IT USES BOTH THE BACK-DRAFT DAMPER AND THE | | | LOUVER. THE INSTALLATION MANUAL DOES NOT ADDRESS THIS | | | KIND OF INSTALLATION. WITH THE X VENT SYSTEM THE BOX OF | | | THE X VENT IS MOUNTED INTO THE EXTERIOR OF THE WALL AND | | | THE LOUVER IS FLUSH TO THE EXTERIOR WALL. THE EXHAUST | | | OF THE DRYER MUST TRAVEL THROUGH THE EXHAUST DUCT, OPEN | | | THE BACK-DRAFT DAMPER AND TRAVEL THROUGH THE X VENT | | | COVER (LOUVER) BEFORE IT IS EXHAUSTED TO THE OUTDOORS. | | | BECAUSE THIS PRODUCT USES BOTH THE BACK-DRAFT DAMPER | | | AND THE OUTER COVER OF THE BOX (LOUVER) INSTEAD OF | | | EITHER THE BACK-DRAFT DAMPER OR THE LOUVER THE DRYER | | | MANUFACTURER MUST ADDRESS THE ASSEMBLY. WE MUST HAVE AN | | | APPROVAL LETTER FROM THE SPECIFIC DRYER MANUFACTURER | | | FOR THE SPECIFIC DRYER USED IN THIS PROJECT. FBC M | | | 504.8.4.2 | | | | | | 6) PLEASE SHOW THAT THE OUTER LOUVER OF THE X VENT | | | COMPLIES WITH AMCA 550. FBC M 501.3.2 | | | | | | 7) PLEASE PROVIDE THE SPECIFICATIONS FROM THE | | | MANUFACTURER OF THE X VENT THAT THE OUTER LOUVER MEETS | | | MINIMUM AND MAXIMUM SIZES. FBC M 501.3.2 | | | | | | 8) PLEASE PROVIDE A DETAIL OF THE PATHWAY FROM THE 4TH | | | FLOOR TO THE EQUIPMENT ON THE ROOF. FBC M 306.5 | | | | | | 9) PLEASE SHOW THAT THE EQUIPMENT ON THE ROOF COMPLIES | | | FOR GUARD PROTECTION. FBC M 304.11 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-06 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-06 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2020-11-06 11:11:32 | SURVEY SHOWS FLOOD ZONE AE 14 NAVD | | | DRAWINGS SHOW FFE AT 16.00 NAVD |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-19 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-19 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2021-03-19 13:34:12 | 03/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-25 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-24 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2021-02-25 12:07:30 | 02/25/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. DONE | | | | | | 2. SECOND REQUEST, ON SHEET A2.1.1 FOR UNITS, 107/207, | | | 108/208, 109/209, AND 110/210 SHOW A SHOWER BUT SHEET | | | P2.1.1 SHOWS TUBS PLEASE CLARIFY WHICH WILL BE USED AND | | | MAKE CHANGES TO ALL OTHER FLOORS AS WELL PLEASE PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | NEW, THE DETAIL FOR THE SUMP PUMP REFERS TO P.6 WHICH | | | THERE ARE TWO PAGE. PLEASE CORRECT AND ADD P 6.1.1 WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION. | | | | | | 3. DONE | | | | | | 4. STRIKE THROUGH ON SHEET A10.1.3 ANY SHOWERS CLEAR | | | FLOOR SPACE NOT USED IN THIS BUILDING AND ANY OTHER | | | DETAILS THAT DO NOT APPLY TO THIS BUILDING PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION. | | | | | | 5. THIS COMMENT APPEARS NOT TO BE UPDATED ON THIS | | | VERSION?ON SHEET A10.1.1 FOR UNIT A1 WITH THE TUB | | | OPTION, IT SHALL HAVE THE CLEAR FLOOR SPACE TO THE SIDE | | | OF THE VALVE ACCESS IN ACCORDANCE WITH THE PARALLEL | | | APPROACH FHADM 7.53. | | | | | | 6. NOTED AND CLARIFIED. | | | | | | 7. DONE. | | | | | | 8. PLEASE PLACE A NOTE THAT THE PERFORATED CAP CAN BE | | | IN THE PLENUM OUT OF THE CAVITY OF THE WALL AND WITH | | | THE MATERIAL THAT HAS A FLAME INDEX LIKE CPVC. THE AIR | | | AD. VA IS NOT CLEAR?ON SHEET P5.1.1 FOR CONDENSATE AND | | | PAN, IT HAS A PERFORATED CAP ON THE FOURTH FLOOR AND | | | NOT VENT OR OUT THE WALL CAVITY PLEASE DETAIL OF A VENT | | | THAT PROVIDES A FLOW OF AIR TO OR FROM A DRAINAGE | | | SYSTEM, OR TO PROVIDE A CIRCULATION OF AIR WITHIN SUCH | | | SYSTEM TO PROTECT TRAP SEALS FROM SIPHONAGE AND | | | BACKPRESSURE PER THE 2017 FBC DEFINITIONS. | | | | | | 9. DONE. | | | | | | 10. DONE | | | | | | 11. DONE. | | | | | | 12. DONE. | | | | | | 13. DONE. | | | | | | 14. DONE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-18 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-04 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2020-11-18 16:09:24 | 11/18/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET C-172 THERE ARE BACKFLOW SHOWN WITH DETAILS | | | AND COMMENTS PLEASE ADD THAT SEPARATE PERMITS ARE | | | REQUIRED BY A LICENSED CONTRACTOR AND CERTIFIED BY THE | | | CITY OF WEST PALM BEACH UTILITIES DEPARTMENT PER THE | | | WPB AMENDMENTS TO THE FBC SEC. 105.1. | | | | | | 2. ON SHEET A2.1.1 FOR UNITS, 107/207, 108/208, | | | 109/209, AND 110/210 SHOW A SHOWER BUT SHEET P2.1.1 | | | SHOWS TUBS PLEASE CLARIFY WHICH WILL BE USED AND MAKE | | | CHANGES TO ALL OTHER FLOORS AS WELL PLEASE PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | 3. ON SHEET A10.1.1 AND A 10.1.2 PLEASE SHOW ALL CLEAR | | | FLOOR SPACE DIMENSIONS FOR ALL AREAS PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION. | | | | | | 4. ON SHEET A10.1.3 PLEASE REMOVE SHOWERS CLEAR FLOOR | | | SPACE NOT USED IN THIS BUILDING AND ANY OTHER DETAILS | | | THAT DO NOT APPLY TO THIS BUILDING PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION. | | | | | | 5. ON SHEET A10.1.1 FOR UNIT A1 WITH THE TUB OPTION, IT | | | SHALL HAVE THE CLEAR FLOOR SPACE TO THE SIDE OF THE | | | VALVE ACCESS IN ACCORDANCE WITH THE PARALLEL APPROACH | | | FHADM 7.53. | | | | | | 6. ON SHEET A10.1.1 PLEASE PROVIDE DETAIL FOR LAV | | | HEIGHT THAT MEET THE REQUIREMENTS OF THE B BATHROOMS IN | | | ACCORDANCE WITH THE FHADM 7.52. | | | | | | 7. ON SHEET P2.1.1 UNIT NEXT TO THE ELEVATOR MISSING A | | | SANITARY DRAIN LINE FOR THE TUB AND THE SAME UNIT | | | DIAGONALLY ACROSS PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | 8. ON SHEET P5.1.1 FOR CONDENSATE AND PAN, IT HAS A | | | PERFORATED CAP ON THE FOURTH FLOOR AND NOT VENT OR OUT | | | THE WALL CAVITY PLEASE DETAIL OF A VENT THAT PROVIDES A | | | FLOW OF AIR TO OR FROM A DRAINAGE SYSTEM, OR TO PROVIDE | | | A CIRCULATION OF AIR WITHIN SUCH SYSTEM TO PROTECT TRAP | | | SEALS FROM SIPHONAGE AND BACKPRESSURE PER THE 2017 FBC | | | DEFINITIONS. | | | | | | 9. ON SHEET P5.1.2 RISER 5 YOU HAVE A WASHING MACHINE | | | ON A BATHROOM GROUP NOT ALLOWED PLEASE HAVE A SEPARATE | | | STACK PER THE 2017 FBC SEC 912.2.1 HORIZONTAL WET VENT. | | | | | | 10. ON SHEET P5.1.3 PLEASE VALVE AT ACCESSIBLE | | | LOCATIONS FOR WATER RISERS PER THE 2017 FBC SEC. 606.1 | | | LOCATION OF FULL-OPEN VALVES. | | | | | | 11. SHEET P5.1.4; | | | A. THERE ARE 5 WASHING MACHINES ON THE BATHROOM GROUP | | | THAT IS NOT ALLOWED PLEASE HAVE A SEPARATE STACK PER | | | THE 2017 FBC SEC 912.2.1 HORIZONTAL WET VENT. | | | | | | B. PLEASE LABEL ALL PIPE SIZES FOR SANITARY DRAINAGE | | | BRANCHES PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | C. PLEASE SHOW TRAP PRIMER FOR FLOOR DRAIN AND GIVE | | | PAGE REFERENCE FOR DETAIL PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | D. THE FLOOR DRAIN IS NOT VENTED PER THE 2017 FBC SEC. | | | 901.2.1 VENTING REQUIRED. | | | | | | E. PLEASE PROVIDE PIPE SIZE FOR THE SUMP PUMP DRAINAGE | | | PER THE WPB AMENDMENTS TO THE FBC SEC. 107.5.1.3 (13) | | | COMMERCIAL PLUMBING. | | | | | | 12. SHEET P5.1.5 PLEASE PROVIDE PIPE SIZING FOR THE | | | WATER RISER REQUIRED PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | 13. SHEET P6.1.1 THERE IS THE DETAIL FOR THE HEATER | | | PLEASE PROVIDE THE THERMAL EXPANSION DEVICE PER THE | | | 2017 FBC SEC. FBC P 607.3. | | | | | | 14. ON SHEET P6.1.2 UNDER ELECTRIC WATER SOURCE | | | SCHEDULE HAS A MIN EFF. OF 0.92 BUT ACCORDING TO NEACA | | | HOT WATER REGULATION 2015 AND IT SHOULD BE AT EF 0.95. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-06 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-06 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2020-11-06 11:21:06 | DEFERRED |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-03-19 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-03-19 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-25 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-25 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-11-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-02 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-02 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2020-11-02 11:59:11 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100734 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE FOLLOWING SHEETS WILL NEED TO BE DIGITALLY | | | SIGNED AND SEALED. | | | SURVEY, C-170, C-171, C-172, C-173, OVERALL SITE PLAN, | | | TIERRA SOILS REPORT. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2021-02-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2021-02-04 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2021-02-04 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-06 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-06 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2020-11-06 11:19:14 | PLEASE REVIEW THE "GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING THRESHOLD/SPECIAL INSPECTORS AND RESIDENT | | | INSPECTORS" AND COMPLY WITH THE REQUIREMENTS AND | | | COMPLETE THE REQUIRED FORMS. | | | PLEASE E MAIL [email protected] FOR A COPY OF THE | | | POLICIES. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-03-25 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-03-24 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2021-03-25 09:33:46 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 03.24.2021 | | | PERMIT NO.: 20100736 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THE SCOPE OF THIS PERMIT REVIEW IS LIMITED TO THE | | | ?BUILDING TYPE II? ONLY. SEPARATE PERMITS REQUIRED FOR | | | ALL OTHER BUILDINGS, SURROUNDING SITE WORK, FENCING, | | | LANDSCAPING, IRRIGATION, ETC. | | | | | | 2. THE BROADSTONE LAKESIDE RESIDENTIAL PLANNED | | | DEVELOPMENT SHALL BE SUBJECT TO ALL DEVELOPMENT ORDER | | | CONDITIONS AS OUTLINED IN RESOLUTION NO. 106-20, AND AS | | | MAY BE AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY | | | RESOLUTION NO. 106-20, AS AMENDED, SHALL BE ADDRESSED | | | WITHIN THE APPROPRIATE SPECIFIED TIMEFRAMES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-02-05 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-02-05 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2021-02-05 11:44:55 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 02.05.2021 | | | PERMIT NO.: 20100734 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - ALL LANDSCAPE PLANS, ETC. SHALL BE | | | REMOVED FROM THE BUILDING PERMIT SUBMITTAL AND | | | SUBMITTED AS PART OF SEPARATE PERMIT APPLICATIONS. THE | | | ONLY PLANS THAT SHOULD BE SUBMITTED WITH THIS PERMIT | | | APPLICATION ARE THOSE THAT ARE NECESSARY FOR THE REVIEW | | | AND ISSUANCE OF THIS PERMIT. ALL PLANS ASSOCIATED WITH | | | SEPARATE PERMITS SHOULD BE REMOVED FROM THE SUBMITTAL. | | | | | | 2. [ NOT SATISFIED ] - AS MODIFICATIONS HAVE BEEN MADE | | | SINCE ADOPTION OF THE DEVELOPMENT ORDER (RESOLUTION NO. | | | 106-20), A MINOR AMENDMENT SHALL BE SUBMITTED TO AND | | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ? | | | PLANNING DIVISION. THIS IS WITH THE ASSUMPTION AND | | | FUTURE CONFIRMATION THAT NONE OF THE CHANGES TRIGGER | | | THE THRESHOLD FOR A MAJOR AMENDMENT, AS SPECIFIED IN | | | THE CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 3. [ SATISFIED ] - PURSUANT TO RESOLUTION NO. 106-20, | | | PRIOR TO THE ISSUANCE OF ANY BUILDING PERMIT: | | | | | | 3.1. [ SATISFIED ] - THE DEVELOPER SHALL PAY TO THE | | | CITY OF WEST PALM BEACH A CONTRIBUTION IN THE AMOUNT OF | | | $30,000 TOWARD TO COST OF A SAFETY STUDY FOR VILLAGE | | | BOULEVARD. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-12-11 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-12-11 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2020-12-11 13:47:50 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 12.11.2020 | | | PERMIT NO.: 20100734 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. ALL LANDSCAPE PLANS, ETC. SHALL BE REMOVED FROM THE | | | BUILDING PERMIT SUBMITTAL AND SUBMITTED AS PART OF | | | SEPARATE PERMIT APPLICATIONS. THE ONLY PLANS THAT | | | SHOULD BE SUBMITTED WITH THIS PERMIT APPLICATION ARE | | | THOSE THAT ARE NECESSARY FOR THE REVIEW AND ISSUANCE OF | | | THIS PERMIT. ALL PLANS ASSOCIATED WITH SEPARATE PERMITS | | | SHOULD BE REMOVED FROM THE SUBMITTAL. | | | | | | 2. AS MODIFICATIONS HAVE BEEN MADE SINCE ADOPTION OF | | | THE DEVELOPMENT ORDER (RESOLUTION NO. 106-20), A MINOR | | | AMENDMENT SHALL BE SUBMITTED TO AND APPROVED BY THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION. | | | THIS IS WITH THE ASSUMPTION AND FUTURE CONFIRMATION | | | THAT NONE OF THE CHANGES TRIGGER THE THRESHOLD FOR A | | | MAJOR AMENDMENT, AS SPECIFIED IN THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | 3. PURSUANT TO RESOLUTION NO. 106-20, PRIOR TO THE | | | ISSUANCE OF ANY BUILDING PERMIT: | | | | | | 3.1. THE DEVELOPER SHALL PAY TO THE CITY OF WEST PALM | | | BEACH A CONTRIBUTION IN THE AMOUNT OF $30,000 TOWARD TO | | | COST OF A SAFETY STUDY FOR VILLAGE BOULEVARD. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|