Plan Review Details - Permit 20100732
Plan Review Stops For Permit 20100732
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2021-01-21 Cont ID  
Sent By cpuell Date 2021-01-21 Time 11:14 Rev Time 0.00
Received By cpuell Date 2021-01-21 Time 11:14 Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-12-11 Cont ID  
Sent By cpuell Date 2020-12-11 Time 14:35 Rev Time 0.00
Received By cpuell Date 2020-12-11 Time 14:35 Sent To  
Notes
2020-12-11 14:35:51HAVE WORKED WITH DEVELOPER ON ADDRESSES, BUT WAS ASKED
 TO HOLD OFF UNTIL THEY OWNED THE PROPERTY. PLEASE
 CONTACT [email protected] TO CONFIRM ADDRESSES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 08:07 Rev Time 0.00
Received By rmcdouga Date 2021-07-08 Time 08:07 Sent To  
Notes
2021-07-08 08:07:21PROJECT IS LOCATED IN SFHA, ELEVATION CERTIFICATES ARE
 REQUIRED.
 DEFERRED SUBMITTALS TO BE STAMPED BY DESIGNER OF RECORD
 AND APPROVED BY BUILDING DEPARTMENT BEFORE BEING
 INSTALLED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2021-06-16 Cont ID  
Sent By pvalenti Date 2021-06-16 Time 07:15 Rev Time 0.00
Received By pvalenti Date 2021-06-15 Time 15:02 Sent To  
Notes
2021-06-16 07:26:12****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.3.4.1 & WPB AMENDMENTS 107.3.4.1, PLEASE LIST
 THE DEFERRED SUBMITTALS, INCLUDING THE PRE-FABRICATED
 FIRE PLACE, ON THE CONSTRUCTION DOCUMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2021-02-12 Cont ID  
Sent By rmcdouga Date 2021-02-12 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2021-02-12 Time 15:30 Sent To  
Notes
2021-02-12 13:39:37PLAN
 REVIEW COMMENTS
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
 POOL PAVILION
 TYPE V-B CONSTRUCTION, UNSPRINKLERED
 GROUP A OCCUPANCY
  
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) [PARTIALLY RESOLVED. THE DATE ON THE REVISED HAS A
 TYPO. THE DATE ON THE REVISED REPORT IS 1/19/20 AND IT
 SHOULD BE 1/19/21. A PRE-CONSTRUCTION ELEVATION
 CERTIFICATE IS REQUIRED TO BE SUBMITTED BEFORE THE
 PERMIT IS ISSUED. ALL OF THE POOL EQUIPMENT IS REQUIRED
 TO BE ELEVATED TO THE DFE (16' NAVD88), TO BE DRY FLOOD
 PROVED OR TO BE FLOOD WATER RESISTANT.] THIS PROJECT IS
 IN A SPECIAL FLOOD HAZARD AREA, AE. THE BFE IS 14'
 NAVD88 AND THE DFE IS 16' NAVD88. THE FINISH FLOOR
 ELEVATION OF THE POOL PAVILION IS SPECIFIED AS 15.2'
 NAVD88 PER THE PAVING AND GRADING PLAN. THIS IS BELOW
 THE REQUIRED DFE AND WILL BE REQUIRED TO BE DESIGNED TO
 COMPLY WITH FLOOD PROVISIONS OF THE FBC AND CITY OF
 WEST PALM BEACH FLOOD ORDINANCE. SHOW HOW THE BUILDING
 WILL COMPLY. IF DESIGNED FOR FLOOD WATERS TO FLOW
 THROUGH THE STRUCTURE ALL EQUIPMENT, CABINETS AND
 CONSTRUCTION MATERIALS THAT WILL BE BELOW DFE (16'
 NAVD) WITH HAVE TO BE ELEVATED OR OF MATERIALS THAT ARE
 RESISTANT TO WATER DAMAGE. SPECIFY THE PROPOSED
 ELEVATION OF THE FINISH FLOOR OF THE POOL PAVILION, IN
 NAVD 88 VERTICAL DATUM, ON THE ARCHITECTURAL PLANS. FBC
 1612
  
 2) RESOLVED.
  
 3) RESOLVED.
  
 4) RESOLVED.
  
 5) RESOLVED.
  
 6) RESOLVED.
  
 7) RESOLVED.
  
 8) [ PARTIALLY RESOLVED. ALTHOUGH THE FBC ACCESSIBILITY
 DOES NOT APPLY TO PRIVATE CLUBS AND POOLS, FAIR HOUSING
 REQUIREMENTS DO APPLY. SEE THE "FAIR HOUSING ACT DESIGN
 MANUAL" CHAPTER 2 ACCESSIBLE AND USABLE COMMON USE
 AREAS. SHOW THE ACCESSIBLE ROUTE TO AND INTO THE POOL
 PAVILION. CLARIFY THE LOCATION OF THE ACCESSIBLE
 ENTRANCE INTO THE PAVILION. IS THERE A RAMP? FBC
 107.2.1]
  
 9) A) [DEFERRED. ADDITIONAL INFORMATION IS REQUIRED TO
 BE SUBMITTED AND APPROVED BEFORE THE PRE-FAB FIREPLACE
 IS INSTALLED.] NOT ENOUGH INFORMATION IS PROVIDED FOR
 THE GAS FIREPLACE. IF IT IS A FACTORY BUILT UNIT
 PROVIDE THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS AND REQUIREMENTS. CITY
 AMENDMENTS FBC 107 & FBC 2111.14.1
  
 10) DEFERRED. FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT
 APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, ROOF VENTS, SWING DOORS AND OVERHEAD
 GARAGE DOORS. THESE ITEMS CAN BE DEFERRED IF REQUESTED,
 HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED
 BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 11) DEFERRED. SUBMIT TRUSS DRAWINGS AND A TRUSS LAYOUT
 PLAN. FBC 2303.4 THESE ITEMS CAN BE DEFERRED IF
 REQUESTED, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND
 APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 12) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By rmcdouga Date 2020-11-12 Time 12:17 Rev Time 0.00
Received By rmcdouga Date 2020-11-10 Time 10:34 Sent To  
Notes
2020-11-12 10:41:04PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
 POOL PAVILION
 TYPE V-B CONSTRUCTION, UNSPRINKLERED
 GROUP A OCCUPANCY
  
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THIS PROJECT IS IN A SPECIAL FLOOD HAZARD AREA, AE.
 THE BFE IS 14' NAVD88 AND THE DFE IS 16' NAVD88. THE
 FINISH FLOOR ELEVATION OF THE POOL PAVILION IS
 SPECIFIED AS 15.2' NAVD88 PER THE PAVING AND GRADING
 PLAN. THIS IS BELOW THE REQUIRED DFE AND WILL BE
 REQUIRED TO BE DESIGNED TO COMPLY WITH FLOOD PROVISIONS
 OF THE FBC AND CITY OF WEST PALM BEACH FLOOD ORDINANCE.
 SHOW HOW THE BUILDING WILL COMPLY. IF DESIGNED FOR
 FLOOD WATERS TO FLOW THROUGH THE STRUCTURE ALL
 EQUIPMENT, CABINETS AND CONSTRUCTION MATERIALS THAT
 WILL BE BELOW DFE (16' NAVD) WITH HAVE TO BE ELEVATED
 OR OF MATERIALS THAT ARE RESISTANT TO WATER DAMAGE.
 SPECIFY THE PROPOSED ELEVATION OF THE FINISH FLOOR OF
 THE POOL PAVILION, IN NAVD 88 VERTICAL DATUM, ON THE
 ARCHITECTURAL PLANS. FBC 1612
  
 2) THE POOL AND DECK ARE REQUIRED TO HAVE SEPARATE
 PERMITS, APPLICATIONS, PLANS AND FEES. CITY AMENDMENTS
 FBC 105
  
 3) THE PROJECT NARRATIVE ON SHEET PP-1 REFERS TO
 PARKING SPACES AND A PARKING GARAGE. THIS PERMIT IS FOR
 THE POOL PAVILION THE GARAGE AND PARKING SPACES ARE
 UNDER SEPARATE PERMITS. PLEASE CORRECT. CITY AMENDMENTS
 FBC 107
  
 4) THE POOL PAVILION IS SPECIFIED ON PP-1 AS A GROUP U
 OCCUPANCY AND A STORAGE GARAGE IS SPECIFIED IN THE
 OCCUPANCY CLASSIFICATION TABLE. IT IS ACTUALLY A GROUP
 A-3 OCCUPANCY. FBC 303.4 PER THE DRAWINGS THE BUILDING
 IS 706 SQFT. AND WITH AN OCCUPANT LOAD FACTOR OF 15 NET
 PER TABLE 1004.5 THE OCCUPANT LOAD IS LESS THAN 50
 PEOPLE. FBC 303.1.1 SMALL BUILDINGS AND TENANT SPACES A
 BUILDING OR TENANT SPACE USED FOR ASSEMBLY PURPOSES
 WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE
 CLASSIFIED AS A GROUP B OCCUPANCY. PLEASE CORRECT.
  
 5) THE LIFE SAFETY PLAN ON PP-1 COMBINES THE OCCUPANT
 CALCULATIONS FOR THE POOL PAVILION WITH THE POOL DECK.
 FOR CLARITY, PLEASE SEPARATE THE POOL PAVILION OCCUPANT
 CALCULATION FROM THE POOL DECK. CITY AMENDMENTS FBC 107
  
 6) THE LIFE SAFETY PLAN LEGEND HAS THE TRAVEL DISTANCE
 OF 200 FEET WITH AUTOMATIC FIRE SPRINKLERS. THIS
 STRUCTURE IS NOT SPRINKLERED. PLEASE CLARIFY. CITY
 AMENDMENTS FBC 107
  
 7) ON THE LIFE SAFETY PLAN IT APPEARS THAT ONE OF THE
 EXIT ACCESS ROUTES FROM THE POOL DECK GOES THROUGH A
 PART OF THE CLUBHOUSE. PLEASE CLARIFY. CITY AMENDMENTS
 FBC 107 & FBC CHAPTER 10
  
 8) SHOW THE REQUIRED PARKING SPACES, THE REQUIRED
 ACCESSIBLE SPACES AND THE ACCESSIBLE ROUTE FROM THE
 PARKING. FBC ACCESSIBILITY CHAPTERS 4 & 5
  
 9 A)NOT ENOUGH INFORMATION IS PROVIDED FOR THE GAS
 FIREPLACE. IF IT IS A FACTORY BUILT UNIT PROVIDE THE
 MANUFACTURER'S SPECIFICATIONS AND INSTALLATION
 INSTRUCTIONS AND REQUIREMENTS. CITY AMENDMENTS FBC 107
 & FBC 2111.14.1
 B) PROVIDE ADDITIONAL INFORMATION ON THE MASONRY
 FIREPLACE. CITY AMENDMENTS FBC 107 PROVIDE DRAWINGS AND
 DETAILS TO SHOW THAT IT COMPLIES WITH FBC 2111 AND
 2113.
  
 10) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, ROOF VENTS, SWING DOORS AND OVERHEAD
 GARAGE DOORS. THESE ITEMS CAN BE DEFERRED IF REQUESTED,
 HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED
 BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 11) SUBMIT TRUSS DRAWINGS AND A TRUSS LAYOUT PLAN. FBC
 2303.4 THESE ITEMS CAN BE DEFERRED IF REQUESTED,
 HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND APPROVED
 BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 12) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2021-02-10 Cont ID  
Sent By jleahy Date 2021-02-10 Time 13:29 Rev Time 0.00
Received By jleahy Date 2021-02-10 Time 13:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-12-01 Cont ID  
Sent By jleahy Date 2020-12-01 Time 14:48 Rev Time 0.00
Received By jleahy Date 2020-12-01 Time 14:03 Sent To  
Notes
2020-12-01 15:17:12ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGES EPP1 AND EPP2 ARE REVERSED IN THE SUBMITTED SET
 WHICH LABELS THEM WRONG.
  
 PAGE EPP 1
  
 RISER DIAGRAM AND PANEL SCHEDULE SHOW DIFFERENT TYPES
 OF WIRES FOR FEEDERS. AL AND CU.
  
 FAULT CURRENT CALCULATION NEEDED FOR SERICE AND PANEL
 110.9, 110,10
  
 INTERSYSTEM BONDING STRIP MIISING FROM SERVICE 250.94

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2021-02-10 Cont ID  
Sent By jleahy Date 2021-02-10 Time 13:29 Rev Time 0.00
Received By jleahy Date 2021-02-10 Time 13:29 Sent To  
Notes
2021-02-10 13:30:22TV'S ONLY JLEAHY

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2020-11-05 Cont ID  
Sent By rrossano Date 2020-11-05 Time   Rev Time  
Received By rrossano Date 2020-11-05 Time   Sent To  
Notes
2020-11-05 08:20:10ONSITE UTILITIES ARE PRIVATE. REVIEWING OVERALL
 ENGINEERING SUBMITTAL E20080019.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2021-01-25 Cont ID  
Sent By pleduc Date 2021-01-25 Time   Rev Time 0.00
Received By pleduc Date 2021-01-25 Time 12:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By pleduc Date 2020-11-04 Time   Rev Time 0.00
Received By pleduc Date 2020-11-04 Time 14:12 Sent To  
Notes
2020-11-04 15:35:19THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) A GAS FIREPLACE IS NOTED, HOWEVER, NO MANUFACTURES
 SPECIFICATION SHEET IS ATTACHED.
  
 PLEASE PROVIDE SPEC SHEETS AS A SUBMITTAL AND ENSURE
 ALL SAFETY RECOMMENDATIONS ARE PROVIDED FOR, INCLUDING,
 NO OPEN FLAME ACCESS AND HOT SURFACE PROTECTION.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By lcrespo Date 2021-03-02 Time 16:30 Rev Time 0.00
Received By lcrespo Date 2021-03-02 Time 15:33 Sent To  
Notes
2021-03-02 16:31:2603/02/21 REVIEWED FOR CODE COMPLIANCE (GAS)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2020-12-01 Cont ID  
Sent By lcrespo Date 2020-12-01 Time 17:22 Rev Time 0.00
Received By lcrespo Date 2020-12-01 Time 17:22 Sent To  
Notes
2020-12-01 17:23:1912/01/20 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE TABLE USED FOR SIZING PIPE REQUIRES 1? FOR THE 2
 COOKING GRILL PLEASE PROVIDE A CORRECT TABLE AS THE
 BTU?S TOTAL 150 NOT 75 PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. THE DISTANCE FOR THE PIPE ON THE FIRE PLACE IS NOT
 LABEL PLEASE PROVIDE PER THE WPB AMENDMENTS TO THE FBC
 SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. REGULATORS INSTALLED OUTDOORS SHALL BE DESIGNED,
 INSTALLED, OR PROTECTED SO THEIR OPERATION WILL NOT BE
 AFFECTED BY THE ELEMENTS. PROVIDE DOCUMENTATION FROM
 THE MANUFACTURER THAT THE REGULATORS ARE APPROVED FOR
 EXTERIOR USE PER THE NFPA 58-11 SEC. 6.8.1.5.
  
 4. PLEASE PROVIDE SPECIFICATION FOR GAS GRILLS AND
 DETAIL OF VENTING UNDER CABINET FORM MANUFACTURES
 SPECIFICATION PER THE 2017 FBC FG SEC.305.1.
  
 5. PLEASE PROVIDE SPECIFICATION FOR FIRE PLACE PER THE
 2017 FBC FG SEC.305.1.
  
 6. PLEASE SHOW ALL UNIONS IN FRONT OF REGULATOR 1? OF
 EITHER SIDE PER THE 2017 FBC RES. SEC G2421.2 OR 2017
 FBC FG SEC 410.2.
  
 7. ON PPP-1 IT SHOWS THE LINES TO THE GRILLS ON 1/2?
 AND ON THE ISOMETRIC ON PPP-2 IT IS 3/4? PLEASE CORRECT
 AND RE0LABEL PER THE WPB AMENDMENTS TO THE FBC SEC.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2021-07-09 Cont ID  
Sent By jleahy Date 2021-07-09 Time 16:12 Rev Time 0.00
Received By jleahy Date 2021-07-06 Time 08:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2021-06-16 Cont ID  
Sent By pvalenti Date 2021-06-16 Time 07:27 Rev Time 0.00
Received By pvalenti Date 2021-05-24 Time 11:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2021-03-02 Cont ID  
Sent By lcrespo Date 2021-03-02 Time 16:58 Rev Time 0.00
Received By lcrespo Date 2021-01-20 Time 10:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-11 Cont ID  
Sent By cpuell Date 2020-12-11 Time 14:36 Rev Time  
Received By cpuell Date 2020-10-23 Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2021-07-23 Cont ID  
Sent By lmarchan Date 2021-07-23 Time 12:18 Rev Time 0.00
Received By lmarchan Date 2021-07-08 Time 08:21 Sent To  
Notes
2021-07-23 12:18:16NO IMPACT FEES DUE PER IMPACT OFFICE. LEM
2021-07-08 08:21:057/8/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2021-03-25 Cont ID  
Sent By lmarchan Date 2021-03-25 Time 11:22 Rev Time 0.00
Received By lmarchan Date 2021-03-25 Time 11:22 Sent To  
Notes
2021-03-25 11:22:06STILL NEEDS IMPACT REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-11-10 Cont ID  
Sent By rmcdouga Date 2020-11-10 Time 10:36 Rev Time 0.00
Received By rmcdouga Date 2020-11-10 Time 10:36 Sent To  
Notes
2020-11-10 10:41:06PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2021-02-03 Cont ID  
Sent By medwards Date 2021-02-03 Time 17:20 Rev Time 0.00
Received By medwards Date 2021-02-03 Time 17:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-11-09 Cont ID  
Sent By medwards Date 2020-11-09 Time 15:18 Rev Time 0.00
Received By medwards Date 2020-11-09 Time 15:03 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2021-06-15 Cont ID  
Sent By pvalenti Date 2021-06-15 Time 16:00 Rev Time 0.00
Received By pvalenti Date 2021-06-15 Time 15:02 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2020-11-12 Cont ID  
Sent By rmcdouga Date 2020-11-12 Time 12:18 Rev Time 0.00
Received By rmcdouga Date 2020-11-12 Time 12:18 Sent To  
Notes
2020-11-12 12:19:29THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA,
 AE. THE BFE IS 14' NAVD88. THE CITY OF WEST PALM
 BEACH'S FLOOD ORDINANCE ADDS A TWO FOOT FREE BOARD TO
 THE BFE WHICH MAKES THE DFE 16'. AS OF OCTOBER 5TH,
 2017, THE CITY HAS ADOPTED NEW FLOOD INSURANCE RATE
 MAPS WHICH USE NAVD 88 AS THE VERTICAL DATUM. THE CITY
 ALSO ADOPTED A 2' FREEBOARD WHICH REQUIRES THE FINISH
 FLOOR AND EQUIPMENT TO BE A MINIMUM OF TWO FEET ABOVE
 THE BFE. ACCORDING TO THE FLOOD INSURANCE RATE MAP
 WHICH WAS ADOPTED ON OCTOBER 5, 2017 AND IS APPLICABLE
 TO THIS PROJECT, THE STRUCTURE IS IN AN AE FLOOD ZONE
 WHICH IS A SPECIAL FLOOD HAZARD AREA. THE CITY OF WEST
 PALM BEACH HAS ADOPTED A FLOOD ORDINANCE THAT REQUIRES
 A TWO (2) FOOT FREE BOARD. SPECIFY ALL ELEVATIONS IN
 NAVD 88. THREE ELEVATION CERTIFICATES ARE REQUIRED TO
 BE SUBMITTED. 1) A PRE-CONSTRUCTION ELEVATION
 CERTIFICATE BASED ON THE CONSTRUCTION PLANS IS REQUIRED
 BEFORE THE PERMIT IS ISSUED. 2) A BUILDING UNDER
 CONSTRUCTION ELEVATION CERTIFICATE WHEN FIRST FLOOR
 SLABS ARE POURED. 3) A FINISHED CONSTRUCTION ELEVATION
 WHEN THE JOB IS COMPLETE INCLUDING LANDSCAPING. THE
 FINAL ELEVATION CERTIFICATE IS REQUIRED TO BE SUBMITTED
 AND APPROVED BEFORE THE C.O. WILL BE ISSUED. SEE
 BUILDING COMMENTS FOR ADDITIONAL COMMENTS.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2021-03-02 Cont ID  
Sent By lcrespo Date 2021-03-02 Time 16:57 Rev Time 0.00
Received By lcrespo Date 2021-03-02 Time 15:33 Sent To  
Notes
2021-03-02 16:57:5103/02/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-12-01 Cont ID  
Sent By lcrespo Date 2020-12-01 Time 17:32 Rev Time 0.00
Received By lcrespo Date 2020-11-04 Time 11:07 Sent To  
Notes
2020-12-01 17:33:1912/01/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE SPECIFICATION FOR TANK-LESS WATER
 HEATER PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. A SEPARATE PERMIT SHALL BE REQUIRED FOR THE BACKFLOW
 DEVICE PER THE WPB AMENDMENTS TO THE FBC SEC. 105.1.
  
 3. THE ICEMAKER SHALL BE EQUIPPED WITH AN IN-LINE
 VACUUM BREAKER THAT COMPLIES WITH ASSE 1024 PER THE
 2017 FBC SEC. 608.13.10.
  
 4. PLEASE PROVIDE A SHUT OFF VALVE FOR THE ICEMAKER AND
 MUST BE ACCESSIBLE FOR SHUTTING OFF WITHOUT MOVING
 UNITS, 2017 FBC SEC. R 2903.9.3 FIXTURE VALVES AND
 ACCESS. ACCESSIBLE SIGNIFIES ACCESS THAT REQUIRES THE
 REMOVAL OF AN ACCESS PANEL OR SIMILAR REMOVABLE
 OBSTRUCTION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2021-02-12 Cont ID  
Sent By rmcdouga Date 2021-02-12 Time 15:30 Rev Time 0.00
Received By rmcdouga Date 2021-02-12 Time 15:30 Sent To  
Notes
2021-02-12 15:33:00NO PRODUCT APPROVALS WERE SUBMITTED. THE PRODUCT
 APPROVALS FOR THE CEMENT TILE ROOFING MATERIALS HAVE
 BEEN DEFERRED. THEY WILL HAVE TO BE SUBMITTED AND
 APPROVED BEFORE INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-11-10 Cont ID  
Sent By rmcdouga Date 2020-11-10 Time 10:42 Rev Time 0.00
Received By rmcdouga Date 2020-11-10 Time 10:42 Sent To  
Notes
2020-11-10 10:46:10NO PRODUCT APPROVALS WERE SUBMITTED FOR THE CEMENT ROOF
 TILE OR ROOF VENTS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2021-07-08 Cont ID  
Sent By rmcdouga Date 2021-07-08 Time 08:35 Rev Time 0.00
Received By rmcdouga Date 2021-07-08 Time 08:29 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2021-06-14 Cont ID  
Sent By medwards Date 2021-06-14 Time 06:57 Rev Time 0.00
Received By medwards Date 2021-06-14 Time 06:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2021-02-03 Cont ID  
Sent By medwards Date 2021-02-03 Time 17:11 Rev Time 0.00
Received By medwards Date 2021-02-03 Time 17:11 Sent To  
Notes
2021-02-03 17:15:48THE SOIL REPORT IS A COPY OF A SIGNATURE AND SEAL OF
 RAJ KRISHNASAMY. BECAUSE THIS WAS SUBMITTED DIGITALLY
 WE WILL NEED THE ORIGINAL DIGITALLY SIGNED AND SEALED
 COPY SUBMITTED OR YOU MAY SUBMIT AN ORIGINAL SIGNED AND
 SEALED PAPER COPY OF THIS REPORT TO OUR OFFICE.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-11-09 Cont ID  
Sent By medwards Date 2020-11-09 Time 15:55 Rev Time 0.00
Received By medwards Date 2020-11-09 Time 15:55 Sent To  
Notes
2020-11-09 15:57:40THE DESIGNERS OF THE FOLLOWING SHHETS MUST DIGITALLY
 SIGN AND SEAL THE DOCUMENTS.
 SOILS REPORT, SURVEY, C-170, C-171, C-172, C-173
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2021-06-14 Cont ID  
Sent By jroach Date 2021-06-14 Time 09:34 Rev Time 0.00
Received By jroach Date 2021-06-14 Time 09:33 Sent To  
Notes
2021-06-14 09:34:17ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 06.14.2021
 PERMIT NO.: 20100732
 ________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. THE SCOPE OF THIS PERMIT REVIEW IS LIMITED TO THE
 POOL PAVILION ONLY. SEPARATE PERMITS REQUIRED FOR ALL
 OTHER BUILDINGS, SURROUNDING SITE WORK, FENCING,
 LANDSCAPING, IRRIGATION, ETC.
  
 2. THE BROADSTONE LAKESIDE RESIDENTIAL PLANNED
 DEVELOPMENT SHALL BE SUBJECT TO ALL DEVELOPMENT ORDER
 CONDITIONS AS OUTLINED IN RESOLUTION NO. 106-20, AND AS
 MAY BE AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY
 RESOLUTION NO. 106-20, AS AMENDED, SHALL BE ADDRESSED
 WITHIN THE APPROPRIATE SPECIFIED TIMEFRAMES.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 2 Status F Date 2021-02-05 Cont ID  
Sent By jroach Date 2021-02-05 Time 11:45 Rev Time 0.00
Received By jroach Date 2021-02-05 Time 11:45 Sent To  
Notes
2021-02-05 11:45:34ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 02.05.2021
 PERMIT NO.: 20100732
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. [ SATISFIED ] - ALL LANDSCAPE PLANS, ETC. SHALL BE
 REMOVED FROM THE BUILDING PERMIT SUBMITTAL AND
 SUBMITTED AS PART OF SEPARATE PERMIT APPLICATIONS. THE
 ONLY PLANS THAT SHOULD BE SUBMITTED WITH THIS PERMIT
 APPLICATION ARE THOSE THAT ARE NECESSARY FOR THE REVIEW
 AND ISSUANCE OF THIS PERMIT. ALL PLANS ASSOCIATED WITH
 SEPARATE PERMITS SHOULD BE REMOVED FROM THE SUBMITTAL.
  
 2. [ NOT SATISFIED ] - AS MODIFICATIONS HAVE BEEN MADE
 SINCE ADOPTION OF THE DEVELOPMENT ORDER (RESOLUTION NO.
 106-20), A MINOR AMENDMENT SHALL BE SUBMITTED TO AND
 APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ?
 PLANNING DIVISION. THIS IS WITH THE ASSUMPTION AND
 FUTURE CONFIRMATION THAT NONE OF THE CHANGES TRIGGER
 THE THRESHOLD FOR A MAJOR AMENDMENT, AS SPECIFIED IN
 THE CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 3. [ SATISFIED ] - PURSUANT TO RESOLUTION NO. 106-20,
 PRIOR TO THE ISSUANCE OF ANY BUILDING PERMIT:
  
 3.1. [ SATISFIED ] - THE DEVELOPER SHALL PAY TO THE
 CITY OF WEST PALM BEACH A CONTRIBUTION IN THE AMOUNT OF
 $30,000 TOWARD TO COST OF A SAFETY STUDY FOR VILLAGE
 BOULEVARD.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-11 Cont ID  
Sent By jroach Date 2020-12-11 Time 13:08 Rev Time 0.00
Received By jroach Date 2020-12-11 Time 13:08 Sent To  
Notes
2020-12-11 13:09:01ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW: 12.11.2020
 PERMIT NO.: 20100732
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. ALL LANDSCAPE PLANS, ETC. SHALL BE REMOVED FROM THE
 BUILDING PERMIT SUBMITTAL AND SUBMITTED AS PART OF
 SEPARATE PERMIT APPLICATIONS. THE ONLY PLANS THAT
 SHOULD BE SUBMITTED WITH THIS PERMIT APPLICATION ARE
 THOSE THAT ARE NECESSARY FOR THE REVIEW AND ISSUANCE OF
 THIS PERMIT. ALL PLANS ASSOCIATED WITH SEPARATE PERMITS
 SHOULD BE REMOVED FROM THE SUBMITTAL.
  
 2. AS MODIFICATIONS HAVE BEEN MADE SINCE ADOPTION OF
 THE DEVELOPMENT ORDER (RESOLUTION NO. 106-20), A MINOR
 AMENDMENT SHALL BE SUBMITTED TO AND APPROVED BY THE
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION.
 THIS IS WITH THE ASSUMPTION AND FUTURE CONFIRMATION
 THAT NONE OF THE CHANGES TRIGGER THE THRESHOLD FOR A
 MAJOR AMENDMENT, AS SPECIFIED IN THE CITY?S ZONING AND
 LAND DEVELOPMENT REGULATIONS.
  
 3. PURSUANT TO RESOLUTION NO. 106-20, PRIOR TO THE
 ISSUANCE OF ANY BUILDING PERMIT:
  
 3.1. THE DEVELOPER SHALL PAY TO THE CITY OF WEST PALM
 BEACH A CONTRIBUTION IN THE AMOUNT OF $30,000 TOWARD TO
 COST OF A SAFETY STUDY FOR VILLAGE BOULEVARD.
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved