| Plan Review Stops For Permit 20100729 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-21 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-21 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2021-01-21 10:30:49 | CLUB HOUSE ADDRESS IS 3590 VILLAGE BLVD |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-11 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-12-11 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2020-12-11 14:59:48 | HAVE WORKED WITH DEVELOPER ON ADDRESSES, BUT WAS ASKED | | | TO HOLD OFF UNTIL THEY OWNED THE PROPERTY. PLEASE | | | CONTACT [email protected] TO CONFIRM ADDRESSES. |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
2 |
Status |
P |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-03-18 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-03-18 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2021-03-18 15:18:47 | OK PER EMAIL FROM S.WELTER | | | |
|
|
| Review Stop |
AIPP |
ART IN PUBLIC PLACES |
| Rev No |
1 |
Status |
N |
Date |
2021-01-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-01-26 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-01-26 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2021-01-26 08:46:04 | ART ASSESSMENT APPLICATION RECEIVED/OPTION 2 | | | (CONTRIBUTION) | | | INVOICE FOR ART FEE SENT 1.22.2021 | | | FEE NOT PAID | | | | | | SYBILLE WELTER | | | ADMINISTRATOR OF PUBLIC ART AND CULTURE | | | DIRECT 561.822.1521 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2021-03-19 14:18:31 | CLUBHOUSE | | | A-3 OCCUPANCY | | | TYPE V-B, UN-SPRINKLERED | | | FBC SIXTH EDITION (2017) | | | | | | 1) DEFERRED SUBMITTALS TO BE SUBMITTED AND APPROVED | | | BEFORE INSTALLATION. | | | | | | 2) SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR: | | | LIGHT POLES/SITE LIGHTING | | | FIRE ALARM | | | FIRE SPRINKLER | | | LOW VOLTAGE | | | ACCESS | | | LANDSCAPING | | | IRRIGATION | | | PARKING LOT | | | SWIMMING POOLS | | | GENERATORS | | | ALL OTHER ITEMS OTHER THAN BMEP | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:24 |
Sent To |
|
|
| Notes |
| 2021-02-16 17:00:59 | PLAN | | | REVIEW COMMENTS | | | | | | CLUBHOUSE | | | A-3 OCCUPANCY | | | TYPE V-B, UN-SPRINKLERED | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PARTIALLY RESOLVED. [THE DATE OF THE REVISED | | | GEOTECHINCAL REPORT IS 1/19/20 AND IT SHOULD BE | | | 1/19/21. ON SHEET OSP-1, THE NOTE UNDER FLOOD ZONE | | | INFORMATION HAS FLOOD ZONE "ABE". PLEASE CORRECT. | | | SUBMIT A PRE-CONSTRUCTION ELEVATION CERTIFICATE. NOTE: | | | ALL EQUIPMENT THAT SERVICES THE BUILDING IS REQUIRED TO | | | BE AT OR ABOVE 16' NAVD 88.] ACCORDING TO THE FLOOD | | | INSURANCE RATE MAP WHICH WAS ADOPTED ON OCTOBER 5, 2017 | | | AND IS APPLICABLE TO THIS PROJECT, THE STRUCTURE IS IN | | | AN AE FLOOD ZONE WHICH IS A SPECIAL FLOOD HAZARD AREA. | | | THE FLOOD ZONE IS AE AND THE BFE IS 14' NAVD88. THE | | | REQUIRED DFE IS 16' NAVD88. THE BUILDING AND ALL OF THE | | | EQUIPMENT SERVICING IT ARE REQUIRED TO BE AT OR ABOVE | | | THE DFE, 16' NAVD88. AS OF OCTOBER 5TH, 2017, THE CITY | | | HAS ADOPTED NEW FLOOD INSURANCE RATE MAPS WHICH USE | | | NAVD 88 AS THE VERTICAL DATUM. THE CITY ALSO ADOPTED A | | | 2' FREEBOARD WHICH REQUIRES THE FINISH FLOOR AND | | | EQUIPMENT TO BE A MINIMUM OF TWO FEET ABOVE THE BFE. | | | SPECIFY ALL ELEVATIONS IN NAVD 88. THREE ELEVATION | | | CERTIFICATES ARE REQUIRED TO BE SUBMITTED. 1) A | | | PRE-CONSTRUCTION ELEVATION CERTIFICATE BASED ON THE | | | CONSTRUCTION PLANS IS REQUIRED BEFORE THE PERMIT IS | | | ISSUED. 2) A BUILDING UNDER CONSTRUCTION ELEVATION | | | CERTIFICATE WHEN FIRST FLOOR SLABS ARE POURED. 3) A | | | FINISHED CONSTRUCTION ELEVATION WHEN THE JOB IS | | | COMPLETE INCLUDING LANDSCAPING. THE FINAL ELEVATION | | | CERTIFICATE IS REQUIRED TO BE SUBMITTED AND APPROVED | | | BEFORE THE C.O. WILL BE ISSUED. | | | | | | 2) RESOLVED. SPECIFY THE FINISH FLOOR ELEVATION ON THE | | | ARCHITECTURAL PLANS. FBC 107.2.1 | | | | | | 3) RESOLVED. THE LIFE SAFETY LEGEND ON SHEET CH-LS-0.1 | | | HAS THE TRAVEL DISTANCE AS 200' FOR PROTECTED WITH | | | AUTOMATIC FIRE SPRINKLERS. FBC TBL 1017.2 HAS 200' FOR | | | NON-SPRINKLERED AND THIS BUILDING IS NOT SPRINKLERED. | | | PLEASE CORRECT. | | | | | | 4) RESOLVED. THE EXIT ACCESS TRAVEL DISTANCE FROM THE | | | WORK ROOM SHOULD BE SHOWN FROM THE MOST REMOTE CORNER | | | OF THE STORAGE ROOM. FBC 1017.3 MEASUREMENT. EXIT | | | ACCESS TRAVEL DISTANCE SHALL BE MEASURED FROM THE MOST | | | REMOTE POINT WITHIN A STORY ALONG THE NATURAL AND | | | UNOBSTRUCTED PATH OF HORIZONTAL AND VERTICAL EGRESS | | | TRAVEL TO THE ENTRANCE TO AN EXIT. | | | | | | 5) RESOLVED. ON SHEET CH-LS-0.1, THE OCCUPANCY | | | SEPARATION REQUIREMENTS SPECIFY FBC TBL. 508.4. THIS | | | TABLE IS FOR SEPARATED OCCUPANCIES. SINCE YOU DO NOT | | | SPECIFY AND FIRE RATED WALLS ON THE PLANS, IT APPEARS | | | THAT YOU WISH TO USE NON-SEPARATED OCCUPANCIES. THE | | | SECTION THAT WOULD APPLY TO THIS PROJECT WOULD BE FBC | | | 508.3 FOR NON-SEPARATED OCCUPANCIES. | | | | | | 6) RESOLVED. THE BUILDING SECTIONS ON SHEET CH-2.2 ARE | | | INCORRECTLY TAGGED AS BEING ON SHEET CH-3.2. THESE | | | SECTION ARE ACTUALLY ON SHEET CH-3.3. PLEASE CORRECT. | | | | | | 7) RESOLVED. PLEASE SHOW THE WHEEL CHAIR TURNING RADIUS | | | SPACE IN THE BATHROOMS. FBC ACCESSIBILITY 304.3 | | | | | | 8) RESOLVED. SHOW THE REQUIRED ACCESSIBLE ACCESS TO THE | | | EXERCISE EQUIPMENT. FBC ACCESSIBILITY 1004.1 CLEAR | | | FLOOR SPACE. EXERCISE MACHINES AND EQUIPMENT SHALL HAVE | | | A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR | | | TRANSFER OR FOR USE BY AN INDIVIDUAL SEATED IN A | | | WHEELCHAIR. CLEAR FLOOR OR GROUND SPACES REQUIRED AT | | | EXERCISE MACHINES AND EQUIPMENT SHALL BE PERMITTED TO | | | OVERLAP. | | | | | | 9) RESOLVED. THE DOOR TO THE WORK ROOM DOES NOT APPEAR | | | TO HAVE THE REQUIRED MINIMUM 18" ON THE PULL SIDE. FBC | | | ACCESSIBILITY 404.2.4.1 SWINGING DOORS AND GATES SHALL | | | HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE | | | 404.2.4.1. | | | | | | 10) RESOLVED. SHOW COMPLIANCE WITH FBC 1210.2.2 WALLS | | | AND PARTITIONS. WALLS AND PARTITIONS WITHIN 2 FEET (610 | | | MM) OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL | | | HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT | | | OF NOT LESS THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN | | | SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY | | | AFFECTED BY MOISTURE. | | | | | | 11) DEFERRED. FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT | | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOWS (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | | | 12) DEFERRED. FBC 107.3.4 SUBMIT TRUSS DRAWINGS, TRUSS | | | LAYOUT PLANS, AND SHOP DRAWINGS FROM OTHER DELEGATE | | | ENGINEERS FOR REVIEW. | | | | | | 13) CORRECTION REQUIRED. [SHEET CH-LS-0.1 UNDER | | | DEFERRED SUBMITTALS THERE ARE SOME ITEMS THAT ARE NOT | | | CORRECT. THE DEFERRED SUBMITTALS CAN BE SUBMITTED TO | | | THE BUILDING DEPARTMENT FOR REVIEW WITH THE PROPER | | | SUBMITTAL FORM AS A NO FEE SUBMITTAL. THE ROOF COVERING | | | WILL REQUIRE A ROOFING SUB-PERMIT THAT CAN BE APPLIED | | | FOR AFTER THE ROOFING PRODUCT APPROVALS HAVE BEEN | | | REVIEWED AND APPROVED BY THE BUILDING DEPARTMENT. THE | | | WINDOWS, DOORS AND STOREFRONTS ARE COVERED UNDER THE | | | BUILDING PERMIT AND DO NOT REQUIRE SEPARATE PERMITS. | | | THE ONLY THING LISTED THAT REQUIRES A SEPARATE PERMIT | | | IS THE LOW VOLTAGE.] FBC 107.3.4.1 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 14) RESOLVED. ART IN PUBLIC PLACES | | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR INFORMATION PLEASE CONTACT: MS. SYBILLE WELTER, ART | | | IN PUBLIC PLACES COORDINATOR AT 822-1515 OR E-MAIL: | | | [email protected] | | | | | | 15) RESOLVED. [THE CONSTRUCTION COSTS IN THE TAKEOFF | | | THAT WAS PROVIDED OF $1,153,100.00 ONLY INCLUDES THE | | | COSTS TO CONSTRUCT THE BUILDING.] IN ORDER TO AVOID | | | PAYING DOUBLE, PLEASE PROVIDE A COST BREAK DOWN FOR THE | | | ITEMS INCLUDED WITH THIS PERMIT THAT DO NOT REQUIRE | | | SEPARATE PERMITS AND FEES. FBC 109.3 BUILDING PERMIT | | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR: | | | LIGHT POLES/SITE LIGHTING | | | FIRE ALARM | | | FIRE SPRINKLER | | | LOW VOLTAGE | | | ACCESS | | | LANDSCAPING | | | IRRIGATION | | | PARKING LOT | | | SWIMMING POOLS | | | GENERATORS | | | ALL OTHER ITEMS OTHER THAN BMEP | | | | | | 16) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-17 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-17 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2020-11-16 10:55:35 | PLAN | | | REVIEW COMMENTS | | | | | | CLUBHOUSE | | | A-3 OCCUPANCY | | | TYPE V-B, UN-SPRINKLERED | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) ACCORDING TO THE FLOOD INSURANCE RATE MAP WHICH WAS | | | ADOPTED ON OCTOBER 5, 2017 AND IS APPLICABLE TO THIS | | | PROJECT, THE STRUCTURE IS IN AN AE FLOOD ZONE WHICH IS | | | A SPECIAL FLOOD HAZARD AREA. THE FLOOD ZONE IS AE AND | | | THE BFE IS 14' NAVD88. THE REQUIRED DFE IS 16' NAVD88. | | | THE BUILDING AND ALL OF THE EEQUIPMENT SERVICING IT ARE | | | REQUIRED TO BE AT OR ABOVE THE DFE, 16' NAVD88. AS OF | | | OCTOBER 5TH, 2017, THE CITY HAS ADOPTED NEW FLOOD | | | INSURANCE RATE MAPS WHICH USE NAVD 88 AS THE VERTICAL | | | DATUM. THE CITY ALSO ADOPTED A 2' FREEBOARD WHICH | | | REQUIRES THE FINISH FLOOR AND EQUIPMENT TO BE A MINIMUM | | | OF TWO FEET ABOVE THE BFE. SPECIFY ALL ELEVATIONS IN | | | NAVD 88. THREE ELEVATION CERTIFICATES ARE REQUIRED TO | | | BE SUBMITTED. 1) A PRE-CONSTRUCTION ELEVATION | | | CERTIFICATE BASED ON THE CONSTRUCTION PLANS IS REQUIRED | | | BEFORE THE PERMIT IS ISSUED. 2) A BUILDING UNDER | | | CONSTRUCTION ELEVATION CERTIFICATE WHEN FIRST FLOOR | | | SLABS ARE POURED. 3) A FINISHED CONSTRUCTION ELEVATION | | | WHEN THE JOB IS COMPLETE INCLUDING LANDSCAPING. THE | | | FINAL ELEVATION CERTIFICATE IS REQUIRED TO BE SUBMITTED | | | AND APPROVED BEFORE THE C.O. WILL BE ISSUED. | | | | | | 2) SPECIFY THE FINISH FLOOR ELEVATION ON THE | | | ARCHITECTURAL PLANS. FBC 107.2.1 | | | | | | 3) THE LIFE SAFETY LEGEND ON SHEET CH-LS-0.1 HAS THE | | | TRAVEL DISTANCE AS 200' FOR PROTECTED WITH AUTOMATIC | | | FIRE SPRINKLERS. FBC TBL 1017.2 HAS 200' FOR | | | NON-SPRINKLERED AND THIS BUILDING IS NOT SPRINKLERED. | | | PLEASE CORRECT. | | | | | | 4) THE EXIT ACCESS TRAVEL DISTANCE FROM THE WORK ROOM | | | SHOULD BE SHOWN FROM THE MOST REMOTE CORNER OF THE | | | STORAGE ROOM. FBC 1017.3 MEASUREMENT. EXIT ACCESS | | | TRAVEL DISTANCE SHALL BE MEASURED FROM THE MOST REMOTE | | | POINT WITHIN A STORY ALONG THE NATURAL AND UNOBSTRUCTED | | | PATH OF HORIZONTAL AND VERTICAL EGRESS TRAVEL TO THE | | | ENTRANCE TO AN EXIT. | | | | | | 5) ON SHEET CH-LS-0.1, THE OCCUPANCY SEPARATION | | | REQUIREMENTS SPECIFY FBC TBL. 508.4. THIS TABLE IS FOR | | | SEPARATED OCCUPANCIES. SINCE YOU DO NOT SPECIFY AND | | | FIRE RATED WALLS ON THE PLANS, IT APPEARS THAT YOU WISH | | | TO USE NON-SEPARATED OCCUPANCIES. THE SECTION THAT | | | WOULD APPLY TO THIS PROJECT WOULD BE FBC 508.3 FOR | | | NON-SEPARATED OCCUPANCIES. | | | | | | 6) THE BUILDING SECTIONS ON SHEET CH-2.2 ARE | | | INCORRECTLY TAGGED AS BEING ON SHEET CH-3.2. THESE | | | SECTION ARE ACTUALLY ON SHEET CH-3.3. PLEASE CORRECT. | | | | | | 7) PLEASE SHOW THE WHEEL CHAIR TURNING RADIUS SPACE IN | | | THE BATHROOMS. FBC ACCESSIBILITY 304.3 | | | | | | 8) SHOW THE REQUIRED ACCESSIBLE ACCESS TO THE EXERCISE | | | EQUIPMENT. FBC ACCESSIBILITY 1004.1 CLEAR FLOOR SPACE. | | | EXERCISE MACHINES AND EQUIPMENT SHALL HAVE A CLEAR | | | FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR TRANSFER | | | OR FOR USE BY AN INDIVIDUAL SEATED IN A WHEELCHAIR. | | | CLEAR FLOOR OR GROUND SPACES REQUIRED AT EXERCISE | | | MACHINES AND EQUIPMENT SHALL BE PERMITTED TO OVERLAP. | | | | | | 9) THE DOOR TO THE WORK ROOM DOES NOT APPEAR TO HAVE | | | THE REQUIRED MINIMUM 18" ON THE PULL SIDE. FBC | | | ACCESSIBILITY 404.2.4.1 SWINGING DOORS AND GATES SHALL | | | HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE | | | 404.2.4.1. | | | | | | 10) SHOW COMPLIANCE WITH FBC 1210.2.2 WALLS AND | | | PARTITIONS. WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) | | | OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE | | | A SMOOTH, HARD, NONABSORBENT SURFACE, TO A HEIGHT OF | | | NOT LESS THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN | | | SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY | | | AFFECTED BY MOISTURE. | | | | | | 11) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | ROOFING MATERIALS, WINDOWS (GLASS TYPES), STRUCTURAL | | | MULLIONS AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE | | | DEFERRED IF REQUESTED, HOWEVER, THE DOCUMENTS MUST BE | | | SUBMITTED AND APPROVED BY THE BUILDING DEPARTMENT | | | BEFORE THEY CAN BE INSTALLED. ONLY ONE SET IS REQUIRED | | | TO BE UPLOADED FOR ELECTRONICALLY SUBMITTED DOCUMENTS. | | | | | | 12) FBC 107.3.4 SUBMIT TRUSS DRAWINGS, TRUSS LAYOUT | | | PLANS, AND SHOP DRAWINGS FROM OTHER DELEGATE ENGINEERS | | | FOR REVIEW. | | | | | | 13) FBC 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES | | | OF THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS | | | THOSE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT | | | THE TIME OF THE APPLICATION AND THAT ARE TO BE | | | SUBMITTED TO THE BUILDING OFFICIAL WITHIN A SPECIFIED | | | PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE | | | PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR | | | DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING | | | OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE | | | IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING. | | | THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED | | | UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN | | | APPROVED BY THE BUILDING OFFICIAL. | | | | | | 14) ART IN PUBLIC PLACES | | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR INFORMATION PLEASE CONTACT: MS. SYBILLE WELTER, ART | | | IN PUBLIC PLACES COORDINATOR AT 822-1515 OR E-MAIL: | | | [email protected] | | | | | | 15) IN ORDER TO AVOID PAYING DOUBLE, PLEASE PROVIDE A | | | COST BREAK DOWN FOR THE ITEMS INCLUDED WITH THIS PERMIT | | | THAT DO NOT REQUIRE SEPARATE PERMITS AND FEES. FBC | | | 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | | REQUIRED FOR: | | | LIGHT POLES/SITE LIGHTING | | | FIRE ALARM | | | FIRE SPRINKLER | | | LOW VOLTAGE | | | ACCESS | | | LANDSCAPING | | | IRRIGATION | | | PARKING LOT | | | SWIMMING POOLS | | | GENERATORS | | | ALL OTHER ITEMS OTHER THAN BMEP | | | | | | 16) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-24 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-24 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2021-03-22 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-03-22 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-03-22 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2021-03-22 11:04:23 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | NEW COMMENT: | | | | | | 1) NEW SHEET CH -0.0 INDEX OF DRAWINGS: NEWLY REVISED | | | SHEET LISTS TWO ADDITIONAL ELECTRICAL DRAWINGS (E-1.0, | | | E-1-1) THAT HAVE NOT BEEN UPLOADED. PLEASE CLARIFY AND | | | UPLOAD MISSING DRAWINGS IF NEEDED. | | | | | | RESPONSE NARRATIVE FROM 3/11/2021 INDICATES THAT COVER | | | SHEET HAS BEEN CORRECTED AND THAT E.1.0 HAS BEEN | | | REMOVED AND A NEW E1.-1 HAS BEEN UPLOADED AS PART OF | | | THE NEW SUBMITAL. THE E.1-1 DRAWING IS STILL MISSING (I | | | COULD NOT FIND IT). PLEASE CLARIFY OR UPLOAD THE E.1-1 | | | DRAWING THAT IS MISSING. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2021-02-08 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2021-02-08 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2021-02-08 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2021-02-08 14:28:41 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | NEW COMMENT: | | | | | | 1) NEW SHEET CH -0.0 INDEX OF DRAWINGS: NEWLY REVISED | | | SHEET LISTS TWO ADDITIONAL ELECTRICAL DRAWINGS (E-1.0, | | | E-1-1) THAT HAVE NOT BEEN UPLOADED. PLEASE CLARIFY AND | | | UPLOAD MISSING DRAWINGS IF NEEDED. | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | | | | ENRIQUE QUINONEZ P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-11-25 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-25 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-25 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2020-11-25 16:51:38 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. | | | | | | 1) PLEASE SHOW LOCATION OF PANEL M. IS THIS PANEL | | | WITHIN THE CLUBHOUSE OR LOCATED DETACHED FROM THE | | | STRUCTURE? FCB 107 | | | 2) GROUNDING ELECTRODE CONDUCTOR FROM METER TO PANEL CH | | | IS TOO SMALL. IT SHOULD BE BASED ON THE EQUIVALENT SIZE | | | OF 1000 KCMIL (2 SETS OF 4#500 KCMIL AL), TABLE 250.66 | | | NEC | | | 3) RISER DIAGRAM SHOWS PANEL M WITH A GROUND CONNECTED | | | TO THE GROUNDING SYSTEM FOR MAIN SERVICE. IF PANEL M IS | | | LOCATED ON A DETACHED STRUCTURE, THEN IT NEEDS TO BE | | | GROUNDED AS PER NEC 250.32 WITH ITS OWN GROUNDING | | | ELECTRODE AND GROUNDING ELECTRODE CONDUCTOR. IF PANEL M | | | IS LOCATED WITHIN THE CLUBHOUSE STRUCTURE IT NEEDS TO | | | BE GROUNDED WITH AN EQUIPMENT GROUNDING CONDUCTOR AS | | | PART OF THE FEEDER FROM PANEL CH. NEC TABLE 250.66, NEC | | | 250.32. | | | 4) PLEASE SHOW FEEDER SIZE (INCLUDE GROUNDING EQUIPMENT | | | CONDUCTOR) FROM PANEL CH TO PANEL M. FCB 107 | | | 5) PANEL M IS SHOWN AS MLO ON PANEL SCHEDULE, BUT RISER | | | DIAGRAM INDICATES A 200 A MCB. PLEASE CORRECT | | | DISCREPANCIES. FCB 107 | | | 6) PANEL SCHEDULE CH DOES NOT HAVE INFORMATION ON | | | BREAKER SIZE AND FEEDER FOR PANEL M AND THIS | | | INFORMATION IS NOT PROVIDED ON RISER DIAGRAM. FCB 107 | | | 7) PANEL CH: PLEASE INCLUDE WIRE (INCLUDING GROUNDING | | | EQUIPMENT CONDUCTOR), CONDUIT SIZES, BREAKER SIZES FOR | | | ALL CH UNITS. CONDUCTORS CAN BE INDICATED ON POWER PLAN | | | IF MORE CONVENIENT. FCB 107 | | | 8) PANEL SCHEDULE M: PLEASE INCLUDE WIRE AND CONDUIT | | | SIZES (INCLUDING GROUNDING EQUIPMENT CONDUCTOR) FOR ALL | | | AC AND CU UNITS. CONDUCTORS CAN BE INDICATED ON POWER | | | PLAN TOO IF MORE CONVENIENT. FCB 107 | | | 9) PLEASE SUBMIT SHORT CIRCUIT CALCULATIONS AND | | | AVAILABLE FAULT CURRENTS FOR PANELS CH AND M NEC 110.24 | | | 10) PANEL SCHEDULE M HAS A NOTE SHOWING A PANEL PV | | | CALCULATION. THIS PANEL IS NOT SHOWN ANYWHERE ELSE AND | | | IS NOT PART OF THE RISER DIAGRAM. THIS LOAD IS NOT | | | INCLUDED IN ANY OF THE LOAD CALCULATIONS EITHER. PLEASE | | | CLARIFY. FCB 107 | | | 11) PLEASE SEE COMMENTS FROM BUILDING REVIEWER | | | REGARDING STRUCTURE BEING ON A SPECIAL FLOOD ZONE AND | | | REQUIREMENTS FOR EQUIPMENT LOCATION. | | | | | | | | | END OF COMMENTS. | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2020-11-05 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2020-11-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-11-05 08:18:31 | ONSITE UTILITIES ARE PRIVATE. REVIEWING OVERALL | | | ENGINEERING SUBMITTAL E20080019. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-03-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-16 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2021-01-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-01-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-01-25 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-11-18 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2020-11-18 13:32:38 | FIRE PROVISO: | | | | | | ALL UNDERGROUND FIRE LINES SHALL BE INSTALLED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS PER NFPA 24 | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-03-24 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-12 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-25 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-01-20 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-11 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-23 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-04-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-04-15 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-03-24 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2021-03-25 11:18:47 | RECEIPT MU-2021-16220 - $5751.15 - PAID | | 2021-03-24 13:59:26 | 3/24/21 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2020-11-16 10:41:32 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-03-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-23 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-23 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-05 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-05 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-02-05 13:38:12 | 2ND REVIEW FBC-2020 MECHANICAL | | | PERMIT-20100729 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2020 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2020 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2020 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) FBC M 403.3.1.1 TELLS US THAT WE MUST USE TABLE | | | 403.3.1.1 AND NOT THE OCCUPANT COUNT FOUND ON THE | | | ARCHITECTURAL SHEETS. PLEASE SUBMIT OUTDOOR AIR | | | CALCULATIONS BASED ON THE USE OF SPACE AND TABLE | | | 403.3.1.1. PLEASE IDENTIFY OCCUPANCY CLASSIFICATION FOR | | | EACH USE OF SPACE INCLUDING THE THEATER. THE | | | CALCULATIONS SUBMITTED IN THIS CYCLE WERE BASED ON THE | | | OCCUPANT COUNT FROM THE ARCHITECTURAL SHEETS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-10 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-10 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2020-11-10 12:55:50 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100729 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE IDENTIFY THE ROOM NAMES THAT ARE USED FOR THE | | | OUTDOOR AIR CALCULATIONS FOR AC-FIT1 & FIT2. PLEASE | | | CALCULATE THE OUTDOOR AREA FOR THE WEIGHT ROOM AND | | | AEROBICS ROOM USING THE NUMBERS PROVIDED UNDER (SPORTS | | | AND AMUSEMENT) FBC M TABLE 403.3.1.1 | | | | | | 2) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS FOR THE | | | ENTIRE BUILDING, PROVIDE OUTDOOR AIR CALCULATIONS BASED | | | ON THE USE OF SPACE IN THIS BUILDING. FBC M TABLE | | | 403.3.1.1 | | | | | | 3) AC CLUB-2; SHEET MCH-3 INDICATES THE TOTAL AIR | | | SUPPLY IS 1400 CFM. SHEET MCH-1 INDICATES THE TOTAL | | | CFM?S IS 1,835. PLEASE SHOW WHERE THE DIFFERENCES ARE. | | | FBC EC M403.2 | | | | | | 4) AC CLUB-1; SHEET MCH-3 INDICATES THE TOTAL AIR | | | SUPPLY IS 1400 CFM. SHEET MCH-1 INDICATES THE TOTAL | | | CFM?S IS 1800. PLEASE SHOW WHERE THE DIFFERENCES ARE. | | | FBC EC M403.2 | | | | | | 5) SHEET MCH-1; UNITS AC-1 AND AC-CLUB2 APPEAR TO HAVE | | | A RETURN COMING FROM THE A/V CLOSET. PLEASE SHOW HOW | | | THIS WOULD MEET FBC M 601.5 (7) | | | | | | 6) SHEET MCH-3 INDICATES THAT EF-1 HAS A TOTAL EXHAUST | | | CFM RATE OF 50 AND IS CONTROLLED BY A LIGHT SWITCH. | | | THIS WOULD NOT COMPLY WITH FBC M TABLE 403.3.1.1 (NOTE | | | E) | | | | | | 7) SHEET MCH-1 PLEASE SHOW CFM?S FOR THE SUPPLY AIR IN | | | THE A/V CLOSET. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2021-03-19 14:26:03 | THE PRE-CONSTRUCTION E.C. HAS BEEN ELECTRONICALLY | | | SUBMITTED, REVIEWED AND APPROVED. THE UNDER | | | CONSTRUCTION AND FINAL ELEVATION CERTIFICATES WILL NEED | | | TO BE SUBMITTED AND APPROVED. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
2 |
Status |
F |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-02-17 08:31:25 | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA), FLOOD ZONE AE. SEE BUILDING REVIEW COMMENTS FOR | | | ADDITIONAL INFORMATION. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2020-11-16 10:59:21 | THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | | (SFHA), FLOOD ZONE AE. SEE BUILDING REVIEW COMMENTS FOR | | | ADDITIONAL INFORMATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-19 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-19 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2021-03-19 15:21:05 | 03/19/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-02-25 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-02-25 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2021-02-25 14:43:01 | 02/25/21 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET CH-5.1; | | | | | | A) PLEASE PROVIDE DIMENSIONS FOR ALL FIXTURE CLEARANCES | | | PER WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | B) DONE. | | | | | | C) DONE. | | | | | | D) THE LAV ON THE OPEN FLOOR NEEDS TO SHOW THE CLEAR | | | FLOOR SPACE NEEDS TO SHOW A FORWARD APPROACH PER THE | | | 2017 FBC SEC. ACC 602.2 CLEAR FLOOR SPACE. | | | | | | E) DONE, NEEDS DIMENSIONS PLEASE, | | | | | | F) DONE. | | | | | | G) DONE. | | | | | | H) NEW, PLEASE REMOVE THE HASH LINE ON THE RESTROOM AND | | | DRINKING FOUNTAIN OF THE CLEAR FLOOR SPACE FOR CLARITY | | | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | I) TOILET ARE DIMENSIONS? AS 1'-6" PLEASE ADD TO IT THE | | | 1'- 4" DIMENSION PER THE 2017 FLORIDA ACC. | | | | | | 2. DONE. | | | | | | 3. DONE. | | | | | | 4. DONE. | | | | | | 5. ON SHEET PCH-2: | | | | | | A) PLEASE PROVIDE THE SIZE OF THE JANITORS SINK UNDER | | | SLAB WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | B) DONE. | | | | | | C) DONE, THE INLINE VACUUM BREAKER IS SHOW UNDERGROUND | | | AND IT NEED TO BE ACCESSIBLE. | | | | | | D) DONE. | | | | | | E) PLEASE ADD TO DETAIL THAT VALVES SHALL COMPLY WITH | | | ASSE 1070 OR CSA B125.3 PER THE 2017 FBC SEC. 416.5 | | | TEMPERED WATER FOR PUBLIC HAND-WASHING FACILITIES. | | | | | | F) PLEASE SHOW SHUT OFF VALVE ON ISOMETRIC PER THE WPB | | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-01 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-01 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-04 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2020-12-02 11:26:18 | 12/01/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET CH-5.1; | | | A) PLEASE GIVE DIMENSIONS FOR FIXTURE CLEARANCES PER | | | FLORIDA BUILDING CODE AND FLORIDA ACCESSIBILITY CODE. | | | | | | B) THE GRAB BARS ARE SHOWN 36? TO CENTER AND THEY NEED | | | TO BE 36? TO TOP OF THE GRIPPING SURFACE PER THE 2017 | | | FBC ACC SEC. 609.4. | | | | | | C) THE DETAIL ON THE ACCESSIBILITY LEGEND FOR THE | | | MIRROR SHOWS IT TO THE BOTTOM AND IT NEEDS TO BE TO THE | | | REFLECTIVE BOTTOM EDGE PER THE 2017 FBC ACC SEC. 603.3. | | | | | | D) THE LAV ON THE OPEN FLOOR NEEDS TO SHOW THE CLEAR | | | FLOOR SPACE OF 30? X 48? PER THE 2017 FBC SEC. ACC | | | 305.3. | | | | | | E) THE DRINKING FOUNTAIN NEEDS TO SHOW THE CLEAR FLOOR | | | SPACE OF 30? X 48? PER THE 2017 FBC SEC. ACC 305.3. | | | | | | F) PLEASE SHOW DETAIL FOR CLEAR FLOOR SPACE IN THE | | | KITCHEN AREA OF 30? X 48? PER THE 2017 FBC SEC. ACC | | | 305.3. | | | | | | G) PLEASE SHOW THAT THE SERVICE SINK (MOP SINK) | | | SURROUNDING THE WALL HAS A NON-ABSORBENT SURFACE IN | | | ACCORDANCE WITH THE 2017 FBC BUILDING SEC. 1210.2.2. | | | PLEASE MAKE A NOTE ON THIS SHEET. | | | | | | 2. ON SHEET A10.1 PLEASE REMOVE SHOWERS CLEAR FLOOR | | | SPACE NOT USED IN THIS BUILDING AND ANY OTHER DETAILS | | | THAT DO NOT APPLY TO THIS BUILDING PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON | | | CONSTRUCTION. | | | | | | 3. ON SHEET PCH-1 AND PCH-2 PLEASE SHOW TRAP PRIMER AND | | | GIVE REFERENCE TO THE PAGE IF DETAIL IS AVAILABLE PER | | | THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION | | | ON CONSTRUCTION DOCUMENTS. | | | | | | 4. PLEASE PROVIDE MANUFACTURE SPECIFICATION FOR | | | TANK-LESS HEATER PER THE WPB AMENDMENTS TO THE FBC SEC. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 5. ON SHEET PCH-2: | | | A) PLEASE PROVIDE HOT AND WATER TO THE MOP SINK ON THE | | | ISOMERIC PER THE 201 FBC SEC. P 607.4. | | | | | | B) PLEASE SHOW SIZING FOR ALL WATER LINE RISER AND | | | LABEL ALL AIR ARRESTORS PER THE WPB AMENDMENTS TO THE | | | FBC SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. | | | | | | C) WATER RAN UNDERGROUND NEED TO BE INSULATED WITH A | | | MINIMUM R-3 PER THE 2017 FBC SEC. RE 403.5.3. | | | | | | D) ICEMAKER NOT SHOWN ON ISOMETRIC PLEASE SHOW A | | | SHUT-OFF VALVE AND IT SHALL BE EQUIPPED WITH AN IN-LINE | | | VACUUM BREAKER THAT COMPLIES WITH ASSE 1024 PER THE | | | 2017 FBC SEC. 608.13.10. | | | | | | E) PLEASE SHOW ON LAVS A TEMPERING DEVICE THAT CONFORMS | | | TO ASSE 1070 OR CSA B125.3 PER THE 2017 FBC SEC. 416.5 | | | TEMPERED WATER FOR PUBLIC HAND-WASHING FACILITIES. | | | | | | F) DUE TO THE LOCATION OF THE HOSE BIBBS IN BATHROOMS, | | | A SHUT OFF VALVE IS RECOMMENDED BUT NOT REQUIRED FOR | | | MAINTENANCE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2021-02-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-02-17 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2021-02-17 08:33:27 | ROOFING PRODUCT APPROVALS ARE BEING DEFERRED. THEY ARE | | | REQUIRED TO BE SUBMITTED AND APPROVED BEFORE THE | | | ROOFING SUB-PERMIT IS ISSUED. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-16 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2020-11-16 10:42:18 | NO PRODUCT APPROVALS WERE SUBMITTED FOR THE ROOFING | | | MATERIALS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-03-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2021-03-19 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-05 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-05 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-10 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-10 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2020-11-10 14:27:21 | DESIGNERS MUST PROVIDE DIGITALLY SIGNED AND SEALED | | | DRAWINGS FOR THE FOLLOWING SHEETS: SOIL REPORT, SURVEY, | | | COVER SHEET, C-107, C-171, C-172, C-173 | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2021-03-24 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-03-24 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-03-24 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2021-03-24 11:43:28 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 03.24.2021 | | | PERMIT NO.: 20100729 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THE SCOPE OF THIS PERMIT REVIEW IS LIMITED TO THE | | | ?CLUBHOUSE? ONLY. SEPARATE PERMITS REQUIRED FOR ALL | | | OTHER BUILDINGS, SURROUNDING SITE WORK, FENCING, | | | LANDSCAPING, IRRIGATION, ETC. | | | | | | 2. THE BROADSTONE LAKESIDE RESIDENTIAL PLANNED | | | DEVELOPMENT SHALL BE SUBJECT TO ALL DEVELOPMENT ORDER | | | CONDITIONS AS OUTLINED IN RESOLUTION NO. 106-20, AND AS | | | MAY BE AMENDED. ALL CONDITIONS OF APPROVAL IMPOSED BY | | | RESOLUTION NO. 106-20, AS AMENDED, SHALL BE ADDRESSED | | | WITHIN THE APPROPRIATE SPECIFIED TIMEFRAMES. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2021-02-05 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2021-02-05 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2021-02-05 11:46:44 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 02.05.2021 | | | PERMIT NO.: 20100729 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. [ SATISFIED ] - ALL LANDSCAPE PLANS, ETC. SHALL BE | | | REMOVED FROM THE BUILDING PERMIT SUBMITTAL AND | | | SUBMITTED AS PART OF SEPARATE PERMIT APPLICATIONS. THE | | | ONLY PLANS THAT SHOULD BE SUBMITTED WITH THIS PERMIT | | | APPLICATION ARE THOSE THAT ARE NECESSARY FOR THE REVIEW | | | AND ISSUANCE OF THIS PERMIT. ALL PLANS ASSOCIATED WITH | | | SEPARATE PERMITS SHOULD BE REMOVED FROM THE SUBMITTAL. | | | | | | 2. [ NOT SATISFIED ] - AS MODIFICATIONS HAVE BEEN MADE | | | SINCE ADOPTION OF THE DEVELOPMENT ORDER (RESOLUTION NO. | | | 106-20), A MINOR AMENDMENT SHALL BE SUBMITTED TO AND | | | APPROVED BY THE DEVELOPMENT SERVICES DEPARTMENT ? | | | PLANNING DIVISION. THIS IS WITH THE ASSUMPTION AND | | | FUTURE CONFIRMATION THAT NONE OF THE CHANGES TRIGGER | | | THE THRESHOLD FOR A MAJOR AMENDMENT, AS SPECIFIED IN | | | THE CITY?S ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 3. [ SATISFIED ] - PURSUANT TO RESOLUTION NO. 106-20, | | | PRIOR TO THE ISSUANCE OF ANY BUILDING PERMIT: | | | | | | 3.1. [ SATISFIED ] - THE DEVELOPER SHALL PAY TO THE | | | CITY OF WEST PALM BEACH A CONTRIBUTION IN THE AMOUNT OF | | | $30,000 TOWARD TO COST OF A SAFETY STUDY FOR VILLAGE | | | BOULEVARD. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-12-11 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-12-11 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2020-12-11 13:37:16 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 12.11.2020 | | | PERMIT NO.: 20100729 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. ALL LANDSCAPE PLANS, ETC. SHALL BE REMOVED FROM THE | | | BUILDING PERMIT SUBMITTAL AND SUBMITTED AS PART OF | | | SEPARATE PERMIT APPLICATIONS. THE ONLY PLANS THAT | | | SHOULD BE SUBMITTED WITH THIS PERMIT APPLICATION ARE | | | THOSE THAT ARE NECESSARY FOR THE REVIEW AND ISSUANCE OF | | | THIS PERMIT. ALL PLANS ASSOCIATED WITH SEPARATE PERMITS | | | SHOULD BE REMOVED FROM THE SUBMITTAL. | | | | | | 2. AS MODIFICATIONS HAVE BEEN MADE SINCE ADOPTION OF | | | THE DEVELOPMENT ORDER (RESOLUTION NO. 106-20), A MINOR | | | AMENDMENT SHALL BE SUBMITTED TO AND APPROVED BY THE | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION. | | | THIS IS WITH THE ASSUMPTION AND FUTURE CONFIRMATION | | | THAT NONE OF THE CHANGES TRIGGER THE THRESHOLD FOR A | | | MAJOR AMENDMENT, AS SPECIFIED IN THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | 3. PURSUANT TO RESOLUTION NO. 106-20, PRIOR TO THE | | | ISSUANCE OF ANY BUILDING PERMIT: | | | | | | 3.1. THE DEVELOPER SHALL PAY TO THE CITY OF WEST PALM | | | BEACH A CONTRIBUTION IN THE AMOUNT OF $30,000 TOWARD TO | | | COST OF A SAFETY STUDY FOR VILLAGE BOULEVARD. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|