Plan Review Details - Permit 20100471
| Plan Review Stops For Permit 20100471 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:40:08 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:47:46 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT A COPY OF THE CONTRACT WITH THE SCOPE OF WORK | | | SPECIFIED. FBC 109.3 BUILDING PERMIT VALUATION. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 2) THE DRYWALL THAT IS BEING REPLACED ON THE CORRIDOR | | | WALLS AND CEILING IS PART OF FIRE RATED ASSEMBLIES. | | | PROVIDE SIGNED AND SEALED DRAWINGS AND DETAILS FROM A | | | FLORIDA LICENSED DESIGN PROFESSIONAL. PROVIDE WALL AND | | | CEILING SECTIONS WITH THE LISTING DETAILS FOR THE FIRE | | | RATED ASSEMBLY. FBC 107.2.1 - INFORMATION ON | | | CONSTRUCTION DOCUMENTS. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-10-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-10-20 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2020-10-20 09:35:32 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) THERE ARE INDICATIONS OF RATED WALL REMOVAL AND | | | RE-CONSTRUCTION, HOWEVER THERE ARE NO DETAILS OF LISTED | | | FIRE RATING DETAILS. | | | | | | PLEASE REVIEW AND PROVIDE. | | | | | | | | | 2) THERE ARE INDICATIONS OF REMOVAL OF CEILING AND WALL | | | MATERIAL; HOWEVER, THERE ARE NO INDICATIONS OF ANY OF | | | THIS WORK THAT MAY AFFECT FIRE SPRINKLER OR FIRE ALARM | | | DEVICES. | | | | | | PLEASE PROVIDE DETAIL INVOLVING FIRE SPRINKLER HEADS. | | | | | | ANY WORK ON FIRE SPRINKLERS OR FIRE ALARM DEVICES, | | | INCLUDING DEMO, SHALL BE DONE UNDER SEPARATE PERMIT AND | | | SHOP DRAWINGS. | | | | | | PROVIDE AN APPLICABLE NOTE OF ACKNOWLEDGEMENT. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-20 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-15 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-19 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:51:00 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 | | | | | | |
|
|
|