| Plan Review Stops For Permit 20100256 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-16 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-16 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-28 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2020-10-28 13:35:38 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE SHOW THE 1ST FLOOR TOILET ROOM DOOR TO COMPLY | | | WITH FBC R320.1.1 | | | ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES, | | | CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE | | | BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE | | | BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH | | | A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING. | | | HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE | | | LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF | | | NOT LESS THAN 29 INCHES (737 MM).-- FBC A 404.2.3 CLEAR | | | WIDTH. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS | | | SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE | | | STOP, WITH THE DOOR OPEN 90 DEGREES. | | | 2) PLEASE SHOW THE DOOR FROM THE GARAGE TO THE LIVING | | | SPACE TO COMPLY WITH FBC R302.5.1 OPENING PROTECTION. | | | OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE | | | EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8 | | | INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMB-CORE | | | STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR | | | 20-MINUTE FIRE-RATED DOORS. | | | 3) PLEASE SHOW THE REQUIREMENT OF "TYPE X" DRYWALL FOR | | | THE GARAGE CEILING - FBC R302.6 | | | 4) PLEASE SHOW THE DRAFT STOPPING AT THE FLOOR FRAMING | | | TO COMPLY WITH FBC R302.12 DRAFTSTOPPING.IN COMBUSTIBLE | | | CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND | | | BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY, | | | DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE | | | CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 | | | M2). DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE | | | INTO APPROXIMATELY EQUAL AREAS. | | | 5) DRAWINGS NEED TO BE SIGNED AND SEALED BY THE | | | ENGINEER. (ELECTRONICALLY SIGNED TO BE USED IN | | | PROJECTDOX ELECTRONIC PLAN REVIEW) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-11-04 |
Time |
20:29 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-11-04 |
Time |
19:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-29 |
Time |
22:24 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-29 |
Time |
21:35 |
Sent To |
|
|
| Notes |
| 2020-10-29 21:49:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. FAULT CURRENT AT FPL TRANSFORMER SECONDARY IS | | | 21200AMPS PER FAULT CURRENT LETTER. NOTE ON PLAN STATES | | | ALL EQUIPMENT WILL BE RATED AT 10,000 AIC. PROVIDE | | | FAULT CURRENT CALCULATION SHOWING FAULT CURRENT RATING | | | FROM SECONDARY OF TRANSFORMER TO SERVICE ENTRANCE | | | EQUIPMENT. NEC 110.10 FBC 107.2.1 | | | | | | 2. SMOKE/CARBON ALARM IN KITCHEN MUST BE ATLEAST 10' | | | AWAY FROM NEAREST COOKING APPLIANCE. NEC 110.3B PROVIDE | | | CORRECTION. | | | | | | 3. BALCONIES ON SECOND FLOOR ARE MISSING REQUIRED | | | RECEPTACLE OUTLETS NEC 210.52E3 | | | | | | 4. TAMPERPROOF RECEPTACLES ARE REQUIRED PER NEC 406.12 | | | PROVIDE CORRECTION. A NOTE ON PLAN WILL SUFFICE. | | | | | | 5. NOTE ON RISER DIAGRAM SAYS "1/0 TO GROUND RODS THEN | | | CW PIPE" BUT DIAGRAM SHOWS #4. PROVIDE CORRECTION. #4 | | | IS ALL THATS REQUIRED FOR GROUND RODS, CW PIPE, AND | | | BUILDING STEEL FYI. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-27 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2020-10-27 12:15:09 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | A SUB GAS PERMIT IS REQUIRED BY A LICENSED CONTRACTOR | | | FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS TO THE FBC | | | SEC. 105.1. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-03 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-29 |
Time |
22:28 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-15 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-12-03 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-17 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2020-12-01 14:24:23 | RECEIPT MU-2020-46445 - $2430.79 - PAID | | 2020-11-17 15:00:54 | 11/17/20 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2020-10-28 13:37:10 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-04 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-04 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-27 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-27 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2020-10-27 10:55:06 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100256 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET AC-1: IT APPEARS THAT THE AC-1 IS LOCATED | | | INSIDE OF THE GARAGE. DUCTS IN THE GARAGE AND DUCTS | | | PENETRATING THE WALLS OR CEILINGS SEPARATING THE | | | DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A | | | MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH (25.4 | | | MM) MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT | | | BOARD, OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE | | | OPENINGS INTO THE GARAGE. FBC RES R302.5.2 | | | | | | 2) SHEET AC-1: PLEASE SHOW THE DRYER DUCT MATERIAL AND | | | THE TERMINATION LOCATION. FBC RES M1502.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-04 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-04 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2020-11-04 14:12:43 | 11/04/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-27 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-27 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2020-10-27 12:15:38 | 10/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-11-13 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-13 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-13 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-28 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2020-10-28 13:39:01 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-11-12 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-11-12 09:51:56 | NO NOTES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-10-27 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-10-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-10-27 10:02:41 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 10/27/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE REQUIRED FRONT SETBACK IS 25 FEET. THE PROPOSED | | | FRONT SETBACK IS (+ -) 19 FEET. | | | 2. THE REQUIRED REAR SETBACK IS 15 FEET OR 10% OF THE | | | LOT DEPTH. THE LOT DEPTH IS 100 FEET. THE REQUIRED REAR | | | SETBACK IS THEN 10 FEET MINIMUM. | | | 3. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4 | | | FEET INTO A REQUIRED SETBACK. THE REQUIRED SIDE SETBACK | | | IS 5 FEET, THIS MEANS THE PROPOSED MECHANICAL EQUIPMENT | | | (GENERATORS, AC EQUIPMENT ETC) MUST BE SETBACK A | | | MINIMUM OF 1 FOOT (12") FROM THE SIDE PROPERTY LINE. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG | | | |
|
|