Plan Review Details - Permit 20100238
Plan Review Stops For Permit 20100238
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2020-10-14 Cont ID  
Sent By cpuell Date 2020-10-14 Time 09:47 Rev Time 0.00
Received By cpuell Date 2020-10-14 Time 09:47 Sent To  
Notes
2020-10-14 09:48:00SUITE 3902 CREATED IN ALL COUNTY AND CITY DATABASES.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2020-10-08 Cont ID  
Sent By cpuell Date 2020-10-08 Time 10:53 Rev Time 0.00
Received By cpuell Date 2020-10-08 Time 10:51 Sent To  
Notes
2020-10-08 10:53:08SUITE 3902 IS NOT CURRENTLY AN OFFICIAL ADDRESS. PLEASE
 REACH OUT TO [email protected] PLEASE SEND A FLOOR PLAN
 FOR THE WHOLE FLOOR AND INDICATE WHERE THE NEW SUITE
 WILL BE. IF THIS SUITE IS EXISTING, PLEASE PROVIDE THE
 PREVIOUS TENANT IN THAT SPACE, SO THAT WE CAN FIND THE
 CORRECT SUITE NUMBER.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2020-10-18 Cont ID  
Sent By jwitmer Date 2020-10-18 Time 16:10 Rev Time 0.00
Received By jwitmer Date 2020-10-18 Time 16:02 Sent To  
Notes
2020-10-18 16:09:42ASBESTOS REPORT SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-13 Cont ID  
Sent By jwitmer Date 2020-11-13 Time 15:57 Rev Time 0.00
Received By jwitmer Date 2020-11-13 Time 15:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-10-18 Cont ID  
Sent By jwitmer Date 2020-10-18 Time 16:57 Rev Time 0.00
Received By jwitmer Date 2020-10-18 Time 16:02 Sent To  
Notes
2020-10-18 16:57:28WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20100238
 ADD: 1411 N. FLAGLER DR. SUITE: 3902
 CONT: TBD/ TO BE DETERMINED
 TEL: ????
 E-MAIL: DOREEN @CDHAIRARCHITECT.COM
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SUN. OCT. 18TH/2020
 ACTION: DENIED
  
 1) PLEASE NOTE IN THE FILE FOLDER THERE ARE TO FILES
 LABELED PERMIT APPLICATION EACH 2 PAGES, BUT THEY ARE
 BLANK. PERMIT LISTED NOW AS CONTRACTOR: TO BE
 DETERMINED.
  
 2) SHEET A.210 THE DEMO FLOOR PLAN ALSO SHOWS THE
 PROPOSED FLOOR PLAN AS WELL. THE UNISEX RESTROOM
 ENLARGED FLOOR PLAN ALSO ON THIS PAGE. AS SHOWN THE
 INSWING DOOR CROSSES OVER THE REQUIRED CLEAR FLOOR
 SPACE FOR BOTH THE LAV AND WATER CLOSET SEE 2017
 FBC-ACCESS. CODE 603.2.3. DOORS SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE OR CLEARANCES REQUIRED FOR ANY
 FIXTURE. DOORS SHALL BE PERMITTED TO SWING INTO THE
 REQUIRED TURNING SPACE. PLEASE SEE EXCEPTION 2. WHERE
 TOILET ROOMS ARE FOR INDIVIDUAL USE AND A CLEAR FLOORS
 SPACE COMPLYING WITH 305.3 IS PROVIDED WITHIN THE ROOM
 BEYOND THE ARC OF THE DOOR SWING. WHAT IS MISSING IS
 THE REQUIRED 30X48 INCH CLEAR FLOOR SPACE BEYOND THE
 ARC OF THE DOOR. USUALLY AT A 45% ANGLE TO THE DOOR
 ENTRANCE.
  
 3) SHEET A310 ACCESSIBILITY RESTROOM WALL DETAILS, THE
 TOILET PAPER DISPENSER IS MISSING THE DIMENSION FROM
 THE FRONT OF THE WATER CLOSET TO THE CENTERLINE OF THE
 DISPENSER. TOILET PAPER DISPENSERS. 604.7. THE TOILET
 PAPER DISPENSER SHALL COMPLY WITH 309.4 AND SHALL BE 7
 INCHES MINIMUM TO 9 INCHES MAXIMUM IN FRONT OF THE
 WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2020-11-04 Cont ID  
Sent By jleahy Date 2020-11-04 Time 16:06 Rev Time 0.00
Received By jleahy Date 2020-11-04 Time 16:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-11-17 Cont ID  
Sent By pleduc Date 2020-11-17 Time   Rev Time 0.00
Received By pleduc Date 2020-11-17 Time 09:12 Sent To  
Notes
2020-11-17 09:12:43FIRE PROVISO:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-10-09 Cont ID  
Sent By pleduc Date 2020-10-09 Time   Rev Time 0.00
Received By pleduc Date 2020-10-09 Time 15:09 Sent To  
Notes
2020-10-09 15:10:12FIRE PROVISO:
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS, INCLUDING DEMO, SHALL BE DONE UNDER
 SEPARATE PERMITS AND SHOP DRAWINGS.
  
 THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE CONSTRUCTION PERIOD, INCLUDING DEMO.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2020-11-18 Time   Rev Time 0.00
Received By lmarchan Date 2020-11-10 Time 14:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-11-04 Cont ID  
Sent By jleahy Date 2020-11-04 Time 16:06 Rev Time 0.00
Received By jleahy Date 2020-10-08 Time 07:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 14:48 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 14:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-10-30 Cont ID  
Sent By medwards Date 2020-10-30 Time 11:57 Rev Time 0.00
Received By medwards Date 2020-10-30 Time 11:55 Sent To  
Notes
2020-10-30 11:57:401ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20100238
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A PERMIT APPLICATION, 2 FILES ARE
 LABELED PERMIT APPLICATION IN THE SUPPORTING DOCUMENTS
 FILE BUT THEY WERE NOT UPLOADED. FBC 107.2
  
 2) PLEASE PROVIDE A SCOPE OF WORK FOR THIS PROJECT. FBC
 107.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-11-18 Cont ID  
Sent By ccole Date 2020-11-18 Time 17:00 Rev Time 0.00
Received By ccole Date 2020-11-18 Time 16:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2020-10-27 Cont ID  
Sent By ccole Date 2020-10-27 Time 09:09 Rev Time 0.00
Received By ccole Date 2020-10-27 Time 07:28 Sent To  
Notes
2020-10-27 09:10:531ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20100238
 10/27/2020
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A210: THE RESTROOM DOOR SHALL NOT SWING INTO
 THE CLEAR FLOOR SPACE OF THE LAVATORY- SECTION 603.2.3
 FBC ACC. PLEASE SEE EXCEPTIONS UNDER 603.2.3.
  
 2) A210 & P1.1: SHOW THE CLEAR FLOOR SPACE APPROACH
 DIAGRAMS AND DIMENSIONS FOR SK 1 & 2- SECTIONS 212.3,
 305.3, & 606.2 FBC ACC.
  
 3) A210: IT APPEARS THAT THE STORAGE RM 307 DOOR WILL
 SWING INTO THE CLEAR FLOOR SPACE FOR SK-1- SECTION
 603.2.3 FBC ACC.
  
 4) A310: SHOW THE CENTERLINE OF THE TOILET PAPER
 DISPENSER MEASURED FROM THE FRONT OF THE WATER CLOSET-
 SECTION 604.7 FBC ACC.
  
 5) P1.1: SHOW A BACKFLOW PREVENTER FOR THE SUPPLY LINE
 TO THE ICE MAKER- SECTION 608.3 FBC P.
  
 6) P0.1 & P1.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE
 ICE MAKER AND INDICATE HOW CONDENSATION FROM THE UNIT
 WILL BE DISPOSED OF- SECTION 314.2.1 FBC P.
  
 7) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB
 WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE
 AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION
 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By medwards Date 2020-11-12 Time 14:51 Rev Time 0.00
Received By medwards Date 2020-11-12 Time 14:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-20 Cont ID  
Sent By equinone Date 2020-10-20 Time 14:37 Rev Time 0.00
Received By equinone Date 2020-10-20 Time 14:37 Sent To  
Notes
***NONE***