| Plan Review Stops For Permit 20100209 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2021-01-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-08 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-08 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2021-01-08 11:46:49 | 212 E LAKEWOOD RD TO REMAIN FOR FRONT PROPERTY AND | | | CASITA (NOT A LEGAL UNIT) |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-17 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-12-17 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2020-12-17 09:34:15 | APPLICANT HAS NOT REACHED OUT YET, COMMENTS STILL | | | STAND: | | | PLEASE REACH OUT TO [email protected] TO DISCUSS | | | ADDRESSING OPTIONS, PREVIOUSLY THERE WERE 2 ADDRESSES | | | ON THE PARCEL, HOWEVER ONE WAS A 1/2 ADDRESS WHICH IS | | | NO LONGER ALLOWED. I WOULD ALSO LIKE TO CHANGE THE | | | ADDRESS TO FALL IN LINE WITH THE CITY ROAD CENTERPOINT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-08 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-08 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2020-10-08 10:42:11 | PLEASE REACH OUT TO [email protected] TO DISCUSS | | | ADDRESSING OPTIONS, PREVIOUSLY THERE WERE 2 ADDRESSES | | | ON THE PARCEL, HOWEVER ONE WAS A 1/2 ADDRESS WHICH IS | | | NO LONGER ALLOWED. I WOULD ALSO LIKE TO CHANGE THE | | | ADDRESS TO FALL IN LINE WITH THE CITY ROAD CENTERPOINT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-21 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-21 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2020-12-21 13:31:31 | 12/18/2020 TALKED TO SOFIA SCIALLA (CONTRACTOR). SHE | | | SAID OK TO PASS BUILDING REVIEW WITH PROVISO. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-THERE ARE 2 SEPARATE PERMIT APPLICATIONS: | | | MAIN HOUSE 20100209 AND GUEST CASITA 20120600. ALL | | | SUBPERMITS TO REFERENCE BOTH PERMIT NUMBERS. | | | | | | 2- ENERGY CALCULATIONS: | | | A)PROVIDE SEPARATE ENERGY CALCULATIONS FOR THE GUEST | | | CASITA. SEC. R101.3 FBC-ENERGY CONSERVATION. | | | B)ENERGY CALCULATIONS SUBMITTED. NEED INFORMATION ON | | | TOP OF FORM: OWNER, BUILDER, PERMIT OFFICE AND | | | JURISDICTION NUMBER 604700. | | | C)REVISE A/C AREA. MAIN HOUSE AND GUEST CASITA AREA TO | | | BE DONE ON SEPARATE FORMS FOR EACH BUILDING. | | | D)REVISE WALL TYPE IN ITEM #9 ON PAGE 1 OF 6. ACCORDING | | | TO PLANS THESE ARE WOOD BEARING WALLS. | | | E)PAGE 2 OF 6 SHOWS A KITCHEN IN-THE GUEST CASITA. | | | THERE IS NOT KITCHEN IN THE GUEST CASITA. | | | F)REVISE/CLARIFY DOORS INFORMATION ON PAGE 4 OF 6. | | | WHERE IS THE 6 X 8 WOOD DOOR BY THE KITCHEN ZONE. ALSO, | | | WHERE ARE THE OTHER TWO WOOD DOORS?. NOTE: GLAZING IN | | | DOORS NEEDS TO BE INCLUDED IN THE WINDOW GLAZING AREA. | | | G)PROVIDE THE NAME OF PERSON GENERATING THE REPORT AS | | | REQUIRED BY SEC. R405.4.2.1 FBC- ENERGY CONSERVATION. | | | H)REVISE WINDOWS OVERHANG SEPARATION TO MATCH PLANS. | | | | | | 3-AS DISCUSSED W/ SOFIA SCIALLA, RESUBMIT PRODUCT | | | APPROVALS (EXCEPT FOR ROOFING PRODUCT APPROVALS). | | | COORDINATE WITH ENGINEER'S LETTER, AND PRODUCT | | | APPROVALS LISTED ON THE PRODUCT APPROVAL SCHEDULE ON | | | SHEET 3 OF 10. | | | | | | 4-PROVIDE ICC EVALUATION REPORT FOR THE ICYNENE | | | INSULATION REVIEWED/APPROVED BY THE DESIGNER OF RECORD. | | | | | | 5-HANDRAILS AND GUARDRAILS DEFERRED SUBMITTAL: PROVIDE | | | SHOP DRAWINGS REVIEWED BY THE DESIGN PROFESSIONAL OF | | | RECORD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-11 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-11 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2020-12-11 18:00:03 | RESIDENTIAL (R3) SECOND BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | ******NOTE: | | | SINCE THERE ARE TWO SEPARATE BUILDINGS IN THIS | | | PROPERTY, THEN A SEPARATE PERMIT APPLICATION WILL BE | | | REQUIRED FOR EACH EACH BUILDING. ONE FOR THE MAIN HOUSE | | | AND ONE FOR THE GUEST CASITA. | | | I GENERATED A NEW PERMIT NUMBER 20120600 FOR THE GUEST | | | CASITA USING THE SAME APPLICATION SUBMITTED FOR THE | | | MAIN HOUSE. GUEST CASITA APPLICATION WAS UPLOADED T | | | PROJECTDOX. SAME PLANS CAN BE USED. I WILL CONTACT | | | CONTRACTOR TO CLARIFY/COORDINATE. | | | SEPARATE PERMIT APPLICATIONS HELP TO COORDINATE | | | INSPECTIONS FOR EACH BUILDING AND TO FACILITATE RECORDS | | | KEEPING. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO IF SURVEY | | | OR SITE PLAN IS PROVIDED SHOWING THE BUILDINGS | | | SETBACKS. | | | | | | PROVISO MEANS CONTRACTOR WILL SUBMIT REQUIRED | | | INFORMATION AFTER THE PERMIT IS ISSUED BUT BEFORE | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS. REVISION FEES | | | MAY APPLY. CONTRACTOR TO ADVICE IF PROVISO OPTION IS | | | PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED | | | INFORMATION BEFORE PERMIT ISSUANCE. | | | | | | | | | | | | | | | ORIGINAL COMMENT: | | | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5.1 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | | REQUIRED PARTIES, INCLUDING THE OWNER OR LEGALLY | | | AUTHORIZED AGENT. | | | | | | RESPONSE: | | | ENERGY CALCULATIONS SUBMITTED: | | | A)THERE ARE TWO SEPARATE BUILDINGS IN THIS PROPERTY. | | | MAIN HOUSE AND GUEST CASITA. NEED A SEPARATE ENERGY | | | CALCULATIONS FOR EACH BUILDING. | | | SEC. R101.2 FBC-ENERGY CONSERVATION. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER, BUILDER AND PERMIT OFFICE AND | | | JURISDICTION NUMBER (THIS JURISDICTION IS 604700) . | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | C)REVISE A/C AREA. MAIN HOUSE AND GUEST CASITA AREA TO | | | BE DONE ON SEPARATE FORMS FOR EACH BUILDING. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | D)REVISE WALL TYPE IN ITEM #9 ON PAGE 1 OF 6. ACCORDING | | | TO PLANS THESE ARE WOOD BEARING WALLS. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | E)PAGE 2 OF 6 SHOWS A KITCHEN IN-THE GUEST CASITA. | | | THERE IS NOT KITCHEN IN THE GUEST CASITA. REVISE THIS | | | WHEN DOING GUEST CASITA ON SEPARATE FORM. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | F)REVISE/CLARIFY DOORS INFORMATION ON PAGE 4 OF 6. | | | WHERE IS THE 6 X 8 WOOD DOOR BY THE KITCHEN ZONE. SEE | | | PLANS AND PRODUCT APPROVALS AND REVISE AS REQUIRED. | | | ALSO, WHERE ARE THE OTHER TWO WOOD DOORS?. NOTE: | | | GLAZING IN DOORS NEEDS TO BE INCLUDED IN THE WINDOW | | | GLAZING AREA. SEE SEC. R405.5.3 FBC-ENERGY | | | CONSERVATION). | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | G)PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS | | | AND GENERATING THE REPORT AS REQUIRED BY SEC. | | | R405.4.2.1 FBC- ENERGY CONSERVATION. | | | | | | H)REVISE WINDOWS OVERHANG SEPARATION TO MATCH PLANS. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | ORIGINAL COMMENT: | | | 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. PROVIDE COMPLETE SITE | | | PLAN DRAWN TO SCALE SHOWING THE BUILDINGS AND PROPOSED | | | DRAINAGE. ALSO, SHOW THE DISTANCES FROM LOT LINES, ETC. | | | SEE SEC. 107.2.5 CITY AMENDMENTS. | | | | | | 3- OK | | | 4- OK | | | 5-OK | | | | | | 6-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | | | | RESPONSE: | | | PRODUCT APPROVALS NEED TO BE COORDINATED. PRODUCT | | | APPROVALS UPLOADED TO PROJECTDOX AND PRODUCT APPROVALS | | | LISTED ON THE SEPARATE ENGINEER'S LETTER (PRODUCT | | | APPROVAL) AND PRODUCT APPROVALS LISTED ON THE PRODUCT | | | APPROVAL SCHEDULE ON SHEET 3 OF 10 DON'T MATCH. | | | PLEASE COORDINATE ALL PRODUCT APPROVALS, PRODUCT | | | APPROVALS NUMBERS, ETC AND RESUBMIT. NOTE: TO AVOID | | | CONFLICTS/DELAYS THIS CAN BE DONE LATER AFTER THE | | | PERMIT IS ISSUED. NO PLAN REVIEW FEE FOR THIS. ALSO, | | | SEE COMMENT BELOW FOR GARAGE DOOR. | | | | | | ******GARAGE DOOR NOA 20-0107.06 SUBMITTED. DOESN'T | | | MEET THE DESIGN PRESSURES CALCULATED BY THE ENGINEER OF | | | RECROD AND NOA DOESN'TMATCH ONE SPECIFIED ON THE | | | PRODUCT APPROVAL SCHEDULE ON SHEET 3 OF 10. | | | | | | ***DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | 7-HOUSE IS DESIGNED WITH UNVENTED ATTIC. DESIGNER OF | | | RECORD IS SPECIFYING ICYNENE SPRAY INSULATION. PROVIDE | | | ICC EVALUATION REPORT FOR THE ICYNENE INSULATION TO | | | VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE THE | | | REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | RESPONSE: | | | NO SUBMITTED. NOTE: THIS MAY BE SUBMITTED LATER AS A | | | DEFERRED SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR | | | TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | | | | | 8-PROVISO: HANDRAILS AND GUARDRAILS DEFERRED SUBMITTAL: | | | PROVIDE SHOP DRAWINGS REVIEWED BY THE DESIGN | | | PROFESSIONAL OF RECORD PRIOR TO INSTALLATION TO AVOID | | | CONFLICTS/DELAYS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-27 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-26 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2020-10-27 09:38:48 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5.1 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE FORMS ARE PROPERLY SIGNED BY ALL | | | REQUIRED PARTIES, INCLUDING THE OWNER OR LEGALLY | | | AUTHORIZED AGENT. | | | | | | 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | R401.3 FBC-RESIDENTIAL. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | SEC. 110.9 CITY AMENDMENTS. | | | | | | 3- ENGINEERING CRITERIA ON SHEET 2 OF 10: | | | A)ACCORDING TO SEC. R301.2.1.4.3 FBC-RESIDENTIAL THIS | | | BUILDING IS LOCATED IN EXPOSURE "D" NOT "C". REVISE AS | | | REQUIRED AND REVISE THE COMPONENTS AND CLADDING DESIGN | | | PRESSURES ACCORDINGLY. | | | | | | B)DESIGN LOADS SPECIFY A FLOOR LIVE/DEAD LOAD OF | | | 100PSF. CLEARLY IDENTIFY THE SECOND FLOOR LIVE LOAD AND | | | DEAD LOAD FOR WHICH FLOOR TRUSSES ARE DESIGNED. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | C) DESIGN LOADS SPECIFY A ROOF LIVE/DEAD LOAD OF 45PSF. | | | CLEARLY IDENTIFY THE ROOF LIVE LOAD AND DEAD LOAD FOR | | | WHICH ROOF TRUSSES ARE DESIGNED, INCLUDING THE ATTIC | | | LIVE LOADS WITH STORAGE. SEC. 107.2.1 CITY AMENDMENTS | | | AND TABLE R301.5 FBC-RESIDENTIAL. | | | | | | 4- SHEET 7 OF 10: | | | A) PROVIDE DETAIL SHOWING HOW THE TWO FLOOR GIRDER | | | TRUSSES ARE CONNECTED TO THE THE WALL WHEN THEY MEET AT | | | THE INTERSECTION BETWEEN THE KITCHEN AREA AND THE | | | MORNING ROOM. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | B) CLARIFY SPACING OF FLOOR TRUSSES SHOWN ON THE FLOOR | | | FRAMING PLAN. THERE IS A NOTE SPECIFYING 24" FLOOR | | | TRUSSES @ 24" O.C, BUT TRUSSES ABOVE OFFICE AND GREAT | | | ROOM ARE SHOWN WHAT LOOKS TO BE 16" O.C. SPACING, WHILE | | | OTHER FLOOR TRUSSES ARE SHOWN WHAT LOOKS TO BE 24" | | | O.C.. REVISE/ CLARIFY AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 5-SPECIFY THE SIZE OF THE ATTIC ACCESS SHOWN ON THE | | | GUEST CASITA, TWO CAR GARAGES IN THE MAIN HOUSE AND IN | | | SECOND FLOOR OF MAIN HOUSE. | | | SEC. R807 FBC-RESIDENTIAL. | | | | | | 6-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B) ROOF TILE AND CLEARLY SPECIFY ROOF TILE FASTENING | | | METHOD AS REQUIRED BY CITY POLICY FOR ALL ROOFING | | | PERMITS. FOR MECHANICALLY ATTACHED TILE PROVIDE | | | COMPLETE TILE FASTENING INFORMATION. | | | | | | C)ROOF TILE ADHESIVE IF SELECTED AS THE FASTENING | | | METHOD. CLEARLY IDENTIFY PADDY SIZE. | | | | | | D)GARAGE OVERHEAD DOOR. NOA 17-1018.12 SUBMITTED | | | EXPIRED ON JULY 21, 2020. NEED CURRENT ONE. | | | | | | E)DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | 7-HOUSE IS DESIGNED WITH UNVENTED ATTIC. DESIGNER OF | | | RECORD IS SPECIFYING ICYNENE SPRAY INSULATION. PROVIDE | | | ICC EVALUATION REPORT FOR THE ICYNENE INSULATION TO | | | VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | | NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE THE | | | REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 8-HANDRAILS AND GUARDRAILS DEFERRED SUBMITTAL: PROVIDE | | | SHOP DRAWINGS REVIEWED BY THE DESIGN PROFESSIONAL OF | | | RECORD PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-03 |
Time |
21:08 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-02-03 |
Time |
20:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-15 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-15 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2020-12-15 09:29:43 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | | | | ELECTRICAL REVIEW STATUS: FAILED, SEE COMMENTS BELOW. | | | | | | FROM PREVIOUS COMMENTS: | | | | | | 1. CANNOT DE-RATE SERVICE ENTRANCE CONDUCTOR SIZES WHEN | | | MORE THAN ONE PANEL SERVES A DWELLING. NEC 310.15 (B) | | | (7) (1) NEC 230.23(A). SIZE 3/0 IS REQUIRED FOR 200AMP | | | SERVICE ENTRANCE CONDUCTORS AND 1/0 IS REQUIRED FOR | | | 150AMP SERVICE ENTRANCE CONDUCTORS | | | | | | THE 150 AMPS SERVICE WAS CHANGED TO 200 AMPS AND IT | | | WILL ALSO REQUIRE A SIZE 3/0 SERVICE ENTRANCE | | | CONDUCTOR. PLEASE CORRECT. | | | | | | NEW COMMENTS: | | | | | | 2. A NEW STEAM UNIT WAS ADDED TO PLANS. THE STEAM UNIT | | | SPECS INDICATES A 7.2 KW/31AMPS LOAD WITH A 40 AMPS | | | FUSE, BUT PANEL SCHEDULE SHOWS A 12KW LOAD WITH 50 AMPS | | | BREAKER. PLEASE CORRECT DISCREPANCIES. | | | | | | 3. PLEASE SHOW CIRCUIT AND DISCONNECT FOR STEAM UNIT ON | | | POWER PLAN | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-26 |
Time |
22:24 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-26 |
Time |
21:41 |
Sent To |
|
|
| Notes |
| 2020-10-26 22:24:54 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. CANNOT DE-RATE SERVICE ENTRANCE CONDUCTOR SIZES WHEN | | | MORE THAN ONE PANEL SERVES A DWELLING. NEC 310.15 (B) | | | (7) (1) NEC 230.23(A) | | | | | | 3/0 IS REQUIRED FOR 200AMP SERVICE ENTRANCE CONDUCTORS | | | AND 1/0 IS REQUIRED FOR 150AMP SERVICE ENTRANCE | | | CONDUCTORS | | | | | | 2. "OPTIONAL" GENERATOR MUST BE REMOVED FROM PLANS. IF | | | AND WHEN A GENERATOR IS INSTALLED IT IS REQUIRED TO BE | | | INSTALLED WITH A SEPARATE STAND ALONE PERMIT. FBC 105.1 | | | FBC 107.2.1 | | | | | | 3. ELECTRICAL NOTE #8 DOES NOT LIST LAUNDRY ROOMS FOR | | | AFCI PROTECTION. PROVIDE CORRECTION. NEC210.12A | | | | | | 4. ALARMS OUTSIDE OF BEDROOMS MUST BE SMOKE/CARBON | | | ALARMS WHEN THE HOME HAS A GAS APPLIANCE, FIREPLACE, OR | | | ATTACHED GARAGE PER FBC RE 314 &315 PROVIDE CORRECTION. | | | | | | 5. PROVIDE NOTE ON PLAN ALL LOW VOLTAGE SYSTEMS WILL | | | REQUIRE A SEPARATE PERMIT. FBC 107.2.1 | | | | | | 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC EC R404.1 | | | | | | | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | IF THE RESUBMITTAL IS NOT PREPARED BY A DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER), AND THE PAGES ARE | | | 11X17 OR SMALLER, YOU MAY RESUBMIT, ALONG WITH A | | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-03 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-03 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-01-06 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-01-06 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2021-01-06 17:47:16 | 2ND REVIEW FBC-2017 RES. FUEL GAS | | | PERMIT- 20100209 | | | 1/6/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. A COMPLETE REVIEW OF THE | | | GAS PLANS WAS NOT COMPLETED AT THIS TIME DUE A LACK OF | | | INFORMATION PROVIDED ON THE PLANS. PLEASE REVIEW THE | | | COMMENTS BELOW AND RESUBMIT COMPLIANT PLANS AND | | | SPECIFICATIONS. | | | | | | 1) SHEET 10 GAS RISER CORRECTIONS- FBC-17 RES. FUEL | | | GAS: | | | A) PROVIDE THE DELIVERY PRESSURE AT THE METER- G2413.1. | | | B) CORRECT THE TOTAL BTU LOAD TO 1020 K- SECTION | | | G2413.2. | | | C) PROVIDE THE TYPES AND SIZES OF BRANCH PIPING TO THE | | | TANKLESS WATER HEATERS AND THE RANGE- G2413.4.1 & | | | G2413.4.2. | | | D) LIST THE PIPE SIZING TABLES USED TO DESIGN THE | | | SYSTEM- G2413.3 & G2413.4. | | | | | | 2) LIST THE MAKES AND MODELS OF THE WATER HEATERS AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS- G2448.1. THE | | | SPECS AND INSTALL MANUALS MAY BE DEFERRED AND SUBMITTED | | | AT A LATER DATE, BUT ALL SPECS AND INSTALL MANUALS | | | SHALL BE ONSITE AT TIME OF INSPECTION- SECTIONS 107.2.1 | | | AND 107.3.4.1 WPB. | | | | | | 3) LIST THE MAKES AND MODELS OF THE FIREPLACE, FIREPIT, | | | POOL HEATER, DRYER, RANGE, AND BBQ GRILL ON THE PLAN | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS. PLEASE NOTE | | | THE SPECS AND INSTALL MANUALS MAY BE DEFERRED AND | | | SUBMITTED AT A LATER DATE, BUT ALL SPECS AND INSTALL | | | MANUALS SHALL BE ONSITE AT TIME OF INSPECTION- SECTIONS | | | 107.2.1 AND 107.3.4.1 WPB. | | | | | | 4) SUBMIT MARKED UP OR HIGHLIGHTED REGULATOR SPECS | | | SHOWING THE SELECTED MODELS, THE MAX INLET AND OUTLET | | | SIZES AND PRESSURES AND ORIFICE SIZES. THE SPECS MAY BE | | | DEFERRED AND BE ONSITE FOR INSPECTION. | | | | | | 5) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE GAS | | | RANGE AND THE FIREPLACE AND SHOW HOW THE AIR IS BEING | | | PROVIDED- SECTION G2407.1. | | | | | | 6) PROVIDE MAKEUP AIR CALCULATIONS FOR THE DRYER AND | | | SHOW HOW THE AIR IS BEING PROVIDED- G2439.5. | | | | | | 7) PROVIDE A VENTING DIAGRAM FOR THE FIREPLACE SHOWING | | | THE TYPE AND SIZE OF VENT FLUE, VENT RUN, AND | | | TERMINATION LOCATION- G2427.8(3). | | | | | | 8) PLEASE SHOW THE LOCATION OF THE FIREPIT ON THE FLOOR | | | PLAN DRAWINGS- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-10-22 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-10-22 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2021-01-06 17:52:39 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | | PERMIT- 20100209 | | | 10/22/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. A COMPLETE REVIEW OF THE | | | GAS PLANS WAS NOT COMPLETED AT THIS TIME DUE A LACK OF | | | INFORMATION PROVIDED ON THE PLANS. PLEASE REVIEW THE | | | COMMENTS BELOW AND RESUBMIT COMPLIANT PLANS AND | | | SPECIFICATIONS. | | | | | | 1) SHEET 10 GAS RISER CORRECTIONS- FBC-17 RES. FUEL | | | GAS: | | | A) PROVIDE THE DELIVERY PRESSURE AT THE METER- G2413.1. | | | B) CORRECT THE TOTAL BTU LOAD TO 1020 K- SECTION | | | G2413.2. | | | C) PROVIDE THE TYPES AND SIZES OF BRANCH PIPING TO THE | | | TANKLESS WATER HEATERS AND THE RANGE- G2413.4.1 & | | | G2413.4.2. | | | D) LIST THE PIPE SIZING TABLES USED TO DESIGN THE | | | SYSTEM- G2413.3 & G2413.4. | | | | | | 2) LIST THE MAKES AND MODELS OF THE WATER HEATERS AND | | | SUBMIT MANUFACTURER'S SPECIFICATIONS- G2448.1. THE | | | SPECS AND INSTALL MANUALS MAY BE DEFERRED AND SUBMITTED | | | AT A LATER DATE, BUT ALL SPECS AND INSTALL MANUALS | | | SHALL BE ONSITE AT TIME OF INSPECTION- SECTIONS 107.2.1 | | | AND 107.3.4.1 WPB. | | | | | | 3) LIST THE MAKES AND MODELS OF THE FIREPLACE, FIREPIT, | | | POOL HEATER, DRYER, RANGE, AND BBQ GRILL ON THE PLAN | | | AND SUBMIT MANUFACTURER'S SPECIFICATIONS. PLEASE NOTE | | | THE SPECS AND INSTALL MANUALS MAY BE DEFERRED AND | | | SUBMITTED AT A LATER DATE, BUT ALL SPECS AND INSTALL | | | MANUALS SHALL BE ONSITE AT TIME OF INSPECTION- SECTIONS | | | 107.2.1 AND 107.3.4.1 WPB. | | | | | | 4) SUBMIT MARKED UP OR HIGHLIGHTED REGULATOR SPECS | | | SHOWING THE SELECTED MODELS, THE MAX INLET AND OUTLET | | | SIZES AND PRESSURES AND ORIFICE SIZES. THE SPECS MAY BE | | | DEFERRED AND BE ONSITE FOR INSPECTION. | | | | | | 5) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE GAS | | | RANGE AND THE FIREPLACE AND SHOW HOW THE AIR IS BEING | | | PROVIDED- SECTION G2407.1. | | | | | | 6) PROVIDE MAKEUP AIR CALCULATIONS FOR THE DRYER AND | | | SHOW HOW THE AIR IS BEING PROVIDED- G2439.5. | | | | | | 7) PROVIDE A VENTING DIAGRAM FOR THE FIREPLACE SHOWING | | | THE TYPE AND SIZE OF VENT FLUE, VENT RUN, AND | | | TERMINATION LOCATION- G2427.8(3). | | | | | | 8) PLEASE SHOW THE LOCATION OF THE FIREPIT ON THE FLOOR | | | PLAN DRAWINGS- SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-03 |
Time |
21:09 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-01-27 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-01-15 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-12-01 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-15 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-11-15 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-08 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-02-01 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-01-15 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2021-02-01 09:17:04 | MU-2021-4071 - $0.00 DUE | | 2021-01-15 15:07:48 | 1/15/21 EMALED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-27 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-27 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2020-10-27 09:41:03 | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2021-02-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-02-01 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-02-01 |
Time |
16:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-12-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-05 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-05 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2020-12-05 10:57:05 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100209 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | PLEASE RESPOND TO THE PREVIOUS REVIEW COMMENTS 4 AND 6. | | | | | | 4) PLEASE PROVIDE DETAILS FOR SECURING THE CONDENSING | | | UNITS. FBC RES M1307.2 | | | | | | 6) PLEASE SHOW ON MECHANICAL DRAWING THE CONDENSATE | | | DISPOSAL LOCATION. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-14 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-14 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2020-10-14 14:10:30 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20100209 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COULD NOT DO A MECHANICAL REVIEW AS THERE WAS NO | | | MECHANICAL INFORMATION SUBMITTED IN THIS SUBMITTAL. | | | | | | 1) PLEASE PROVIDE CODE COMPLIANT MECHANICAL DRAWINGS | | | FOR THIS NEW RESIDENCE. FBC 107.2.1 | | | | | | 2) PLEASE PROVIDE ENERGY CALCULATIONS. FBC EC | | | 101.5.1.1.2 | | | | | | 3) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FBC EC R403.7 | | | | | | 4) PLEASE PROVIDE DETAILS FOR SECURING THE CONDENSING | | | UNITS. FBC RES M1307.2 | | | | | | 5) PLEASE PROVIDE DETAILS OF THE RETURN AIR BALANCING | | | ON THE DRAWINGS. FBC RES M1602.3 | | | | | | 6) PLEASE SHOW ON MECHANICAL DRAWING THE CONDENSATE | | | DISPOSAL LOCATION. FBC RES M1411.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2021-02-03 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2021-02-03 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-12-09 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-12-09 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2020-12-09 17:39:05 | 2ND REVIEW FBC-2017 RES. PLUMBING | | | PERMIT- 20100209 | | | 12/9/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS 10A & 10B: THE NEW WATER RISERS SHOW 3/8 IN. | | | FIXTURE SUPPLY PIPES TO THE 1ST FLOOR SINKS, WASHING | | | MACHINE, AND THE 2ND FLOOR BATHTUB, SHOWERS, AND SINKS. | | | PLEASE REFER TO SECTIONS P2601.1 P2903.8.2 FBC RES, AND | | | TABLE 604.5 FBC P AND PROVIDE MIN. 1/2 IN. SUPPLY PIPES | | | TO THE FIXTURES. | | | | | | 2) SHEETS 10,10A, & 10B: BASED ON THE NEW NOTES | | | CONCERNING THE HOT WATER SYSTEM IT APPEARS A | | | RECIRCULATING PUMP WILL BE INSTALLED. ARE THE TANKLESS | | | WATER HEATERS EQUIPPED WITH RECIRCULATION PUMPS OR WILL | | | A SEPARATE PUMP BE INSTALLED? PLEASE PROVIDE ADDITIONAL | | | INFORMATION AND DETAILS- SECTION 107.2.1 WPB. PLEASE | | | REVISE THE NOTES TO INDICATE THE APPLICABLE CODE | | | SECTIONS FROM THE FBC RES AND FBC EC. | | | | | | 3) COMMENT #5 FROM THE 1ST REVIEW CONCERNING THE HOT | | | WATER SYSTEM PARTIALLY ADDRESSED. PLEASE PROVIDE WATER | | | HEATER EQUIPMENT SCHEDULES THAT INCLUDE THE EFFICIENCY | | | RATINGS ON THE PLAN AND SUBMIT MANUFACTURER'S | | | SPECIFICATIONS- SECTIONS P2801.3 & G2448.1 FBC RES. | | | | | | 4) SHEET 10: 2ND REQUEST TO SHOW A TWO-WAY CLEANOUT | | | WILL BE INSTALLED AT THE BUILDING DRAIN/SEWER PIPE | | | JUNCTIONS- SECTION P3005.2.8 FBC RES. | | | | | | 5) SHEET 10: AS PREVIOUSLY NOTED A SEPARATE PERMIT AND | | | PLANS ARE REQUIRED FOR THE GAS PIPING INSTALLATIONS- | | | SECTIONS 105.1 & 107.2.1 WPB. A COMPLETE REVIEW OF THE | | | REQUIRED GAS PIPING SYSTEMS, THE APPLIANCES AND | | | GENERATOR SHOWN ON THE PLAN, AND THE REQUIRED | | | COMBUSTION AIR AND VENTING PLANS WILL NOT BE PERFORMED | | | UNDER THIS PERMIT. | | | | | | 6) 2ND REQUEST FOR A PLUMBING SUB-PERMIT- SECTION 105.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-10-22 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-10-22 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2020-10-22 12:43:07 | 1ST REVIEW FBC-2017 RES. PLUMBING | | | PERMIT- 20100209 | | | 10/22/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SUBMIT A PLUMBING SUB-PERMIT APPLICATION- SECTION | | | 105.1 WPB. | | | | | | 2) PLEASE NOTE A SEPARATE PERMIT AND PLANS ARE REQUIRED | | | FOR THE GAS PIPING INSTALLATIONS- SECTIONS 105.1 & | | | 107.2.1 WPB. A COMPLETE REVIEW OF THE REQUIRED GAS | | | PIPING SYSTEMS, THE APPLIANCES AND GENERATOR SHOWN ON | | | THE PLAN, AND THE REQUIRED COMBUSTION AIR AND VENTING | | | PLANS WILL NOT BE PERFORMED UNDER THIS PERMIT. | | | | | | 3) PLEASE PROVIDE A PLUMBING FLOOR PLAN AND SITE | | | DRAWING SHOWING THE SANITARY DRAINAGE AND WATER | | | DISTRIBUTION PIPING LAYOUTS INCLUDING THE LOCATIONS OF | | | THE WATER METER, MAIN SHUTOFFS VALVES FOR THE MAIN | | | HOUSE AND GUEST HOUSE, LOCATIONS OF BACKFLOW PREVENTERS | | | FOR THE MAIN POTABLE WATER SUPPLY SYSTEMS, AND AT WATER | | | SUPPLY CONNECTIONS TO IRRIGATION SYSTEMS AND POOL | | | EQUIPMENT, AND LOCATIONS OF HOSE BIBS- SECTION 107.2.1 | | | WPB AND SECTIONS P2902.1, P2902.1, P2903.1 & P2903.9 | | | FBC RES. PLEASE PROVIDE COMPLETE PLUMBING NOTES | | | INDICATING AT A MINIMUM THE TYPES OF PIPING MATERIALS, | | | FIXTURE SHUTOFF VALVES, INDIVIDUAL BATHTUB AND SHOWER | | | VALVES, AND PIPE INSULATIONS TO BE INSTALLED ETC.- | | | P2609 FBC RES. | | | | | | 4) SHEET 10 SANITARY RISER: | | | | | | A) SHOW THE REQUIRED 3 IN. FIXTURE BRANCH DRAINS AND | | | STACKS FOR THE WASHING MACHINES- SECTION 406.2 FBC P. | | | | | | B) SHOW THE REQUIRED CLEANOUTS AT THE BASES OF THE 3 | | | VERTICAL STACKS- SECTION P3005.2.4 FBC RES. | | | | | | C) THE WATER CLOSET IN THE ENSUITE BATHROOM WILL | | | REQUIRE AN INDIVIDUAL VENT BECAUSE IT IS NOT PART OF | | | THE BATHROOM WET VENT- NOT MORE THAN ONE WET-VENTED | | | FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF THE | | | DRY-VENTED FIXTURE DRAIN CONNECTION- SECTION P3108.2.1 | | | FBC RES. | | | | | | D) SHOW THE DISHWASHER DRAIN CONNECTION- SECTION | | | P2717.2 FBC RES. | | | | | | E) PROVIDE A CLEANOUT AT THE JUNCTION OF THE GUEST | | | HOUSE BUILDING DRAIN AND BUILDING SEWER- SECTION | | | P3005.2.3 FBC RES. SHOW A TWO-WAY CLEANOUT WILL BE | | | INSTALLED BUILDING DRAIN/SEWER PIPE JUNCTIONS- SECTION | | | P3005.2.8 FBC RES. | | | | | | F) SHOW THE LOCATION OF THE CLEANOUT FOR THE OUTDOOR | | | PATIO SINK- SECTION P3003.5.2. | | | | | | G) IT APPEARS THAT THE DRAIN AND VENT FOR ONE OF THE | | | KITCHEN ISLAND SINKS IS MISSING FROM THE DRAWING- | | | SECTION 107.2.1 WPB. | | | | | | 5) INDICATE HOW HOT WATER WILL BE PROVIDED TO THE | | | FIXTURES- SECTION P2801.1 FBC RES. PROVIDE A FLOOR PLAN | | | DRAWING SHOWING THE LOCATIONS OF THE WATER HEATERS. | | | PROVIDE EQUIPMENT SCHEDULES ON THE PLAN AND SUBMIT | | | MANUFACTURER?S SPECIFICATIONS- SECTIONS P2801.3 & | | | G2448.1 FBC RES. IT APPEARS FROM THE ELECTRICAL | | | DRAWINGS THAN GAS-FIRED TANKLESS WATER HEATERS WILL BE | | | INSTALLED. PLEASE PROVIDE PIPING DIAGRAMS FOR THE | | | UNITS. | | | | | | 6) PROVIDE A WATER RISER DRAWING PER SECTION 107.2.3.2 | | | WPB. SHOW PIPE SIZES AND LOCATIONS OF SHUTOFF VALVES, | | | BACKFLOW PREVENTERS, WATER HAMMER ARRESTORS ETC. PLEASE | | | NOTE THAT WATER HAMMERS ARE REQUIRED FOR SUPPLY LINES | | | TO THE WASHING MACHINES, DISHWASHERS AND ICE MAKERS- | | | SECTION P2903.5 FBC RES. BACKFLOW PREVENTERS ARE | | | REQUIRED FOR SUPPLY LINES TO THE STEAM UNIT AND ICE | | | MAKERS- SECTION P2902.3. THE SUPPLY LINE DISHWASHER | | | SHALL BE PROTECTED AGAINST BACKFLOW BY AN AIR GAP OR | | | BACKFLOW PREVENTER- SECTION P2717.1. | | | | | | 7) INDICATE HOW WATER UNDERGROUND PIPING AND PIPING | | | PENETRATING CONCRETE SLABS WILL BE PROTECTED AGAIN | | | CORROSION- SECTION P2603.3. | | | | | | 8) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE | | | STEAM UNIT AND SUBMIT THE MANUFACTURER'S SPECIFICATIONS | | | AND INSTALLATION MANUAL - SECTION M1307.1 FBC RES. | | | | | | 9) INDICATE HOW CONDENSATE FROM THE STEAM UNIT AND ICE | | | MAKER WILL BE DRAINED AND DISPOSED. SHOW THE TYPE AND | | | SIZE OF PIPING, PIPING RUNS, AND DISCHARGE LOCATIONS- | | | SECTION 314 FBC P. | | | | | | 10) PROVIDE ENLARGED SHOWER RECESS AND SHOWER PAN | | | DETAILS- SECTIONS P2709.1 & P2709.2 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2021-02-05 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2021-02-05 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2021-02-05 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2021-02-05 08:45:25 | APPROVED, PRIVATE PROVIDER INSPECTIONS ONLY | | | | | | PLANNING AND BUILDING CONSULTANTS, LLC | | | | | | APPROVED | | | | | | RICHARD GATHRIGHT | | | ASSISTANT BUILDING OFICIAL | | | 561 805 6679 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-12-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-17 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-17 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2020-12-17 10:44:05 | 1- ROOF TILE FL7473-R8 | | | 2- ROOF TILE ADHESIVE FL 6332-R8 | | | 3- MODIFIED BITUMEN FL16709-R6 | | | 4- METAL CHANNEL FL5374-R5 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-27 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-27 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2020-10-27 09:43:13 | 1-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO | | | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT | | | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL): | | | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B) ROOF TILE AND CLEARLY SPECIFY ROOF TILE FASTENING | | | METHOD AS REQUIRED BY CITY POLICY FOR ALL ROOFING | | | PERMITS. FOR MECHANICALLY ATTACHED TILE PROVIDE | | | COMPLETE TILE FASTENING INFORMATION. | | | | | | C)ROOF TILE ADHESIVE IF SELECTED AS THE FASTENING | | | METHOD. CLEARLY IDENTIFY PADDY SIZE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2021-02-03 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2021-02-03 |
Time |
21:09 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2021-02-03 |
Time |
21:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-09 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-09 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2020-12-09 17:31:42 | SOIL TEST REPORT WITH ENGINEER'S ORIGINAL | | | SEAL/SIGNATURE. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-10-27 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-27 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2020-10-27 09:51:53 | 1-SOIL TEST REPORT NEED TO HAVE THE ENGINEER'S ORIGINAL | | | SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 F.S. WHEN | | | SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | PLEASE UPLOAD TO PROJECTDOX SOIL TEST REPORT WITH | | | ENGINEER'S DIGITAL SIGNATURE OR PROVIDE HARD COPY OF | | | SOIL TEST REPORT L WITH ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2021-01-15 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2021-01-15 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2021-01-15 |
Time |
12:24 |
Sent To |
I |
|
| Notes |
| 2021-01-15 12:26:04 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED HOME ON AN | | | ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION 94-611, | | | HEIGHT SHALL BE MEASURED AS THE VERTICAL DISTANCE FROM | | | THE AVERAGE ELEVATION OF THE FINISHED GRADE OF THE | | | BUILDING TO THE HIGHEST POINT OF THE TOP OF THE | | | STRUCTURE OF A FLAT ROOF, OR TO THE DECK LINE OF A | | | MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL BETWEEN EAVES | | | AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-11-13 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-11-13 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-11-13 |
Time |
15:33 |
Sent To |
I |
|
| Notes |
| 2020-11-13 15:39:21 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. INDICATE PRINCIPAL STRUCTURE SETBACKS TO ALL | | | PROPERTY LINES. NOTE: CITY OF WEST PALM BEACH ZONING | | | AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-72: | | | SINGLE FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT - | | | MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET | | | | | | B. CORNER: 12.5 FEET | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF DEPTH, WHICHEVER IS | | | LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|