| Plan Review Stops For Permit 20091290 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-08 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-08 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-04 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2020-11-04 15:43:14 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE EXPOSURE CATEGORY IS STILL SPECIFIED AS C ON | | | SHEET T-1 IN THE LOADING CRITERIA. THE DRAWINGS SPECIFY | | | THAT THE EXPOSURE CATEGORY IS C. THIS PROJECT IS | | | LOCATED IN EXPOSURE CATEGORY D. FBC 1609.4 | | | | | | 2) THIS ITEM HAS NOT BEEN FULLY ADDRESSED. ON SHEET | | | C-5, SPECIFY THE REQUIRED EMBED DEPTH AND THE ANCHOR | | | SPACING REQUIRED FOR ATTACHING THE THE UNISTRUT TO THE | | | WALL OF THE BUILDING. CITY AMENDMENTS FBC 107.2.1 | | | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-14 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-14 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2020-10-14 14:00:43 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE APPURTENANCE MOUNT MODIFICATION ANALYSIS STATES | | | THAT IT WAS DONE IN ACCORDANCE WITH THE 2018 | | | INTERNATIONAL BUILDING CODE. THE 2018 IBC HAS NOT BE | | | ADOPTED BY THE STATE OF FLORIDA AT THIS TIME. THE | | | CURRENT CODE IS THE 2017 FLORIDA BUILDING CODE. PLEASE | | | REVISE. | | | | | | 2) THE DRAWINGS SPECIFY THAT THE EXPOSURE CATEGORY IS | | | C. THIS PROJECT IS LOCATED IN EXPOSURE CATEGORY D. FBC | | | 1609.4 | | | | | | 3) ON DRAWING SHEET C-3, THE RRUS UNITS ARE SHOWN AS | | | BEING RELOCATED TO UNISTRUT ATTACHED TO THE WALL OF THE | | | BUILDING. PROVIDE ATTACHMENT DETAILS WITH THE REQUIRED | | | NUMBER AND TYPES OF FASTENERS FOR ATTACHING THE | | | UNISTRUT AND MOUNTING THE BOXES TO THE UNISTRUT. CITY | | | AMENDMENTS FBC 107.2.1 | | | | | | 4) THE ENGINEER THAT DIGITALLY SIGNED AND SEALED THE | | | APPURTENANCE MOUNT MODIFICATION ANALYSIS, SELF | | | CERTIFIED HIS SIGNATURE. THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS REQUIRES ENGINEERS TO HAVE A | | | THIRD PARTY CERTIFICATION OF THEIR DIGITAL SIGNATURES. | | | | | | 5) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-06 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-06 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2020-11-06 10:57:27 | NO CHANGES TO ELECTRICAL DRAWINGS. PLANS STAMPED BY | | | JAKE. EQ |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-08 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-08 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-08 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-20 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-16 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-10-30 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-14 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-01 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-08 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-08 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-04 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-14 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-14 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2020-12-02 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-12-02 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-12-02 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2020-12-02 10:39:11 | PROVISO | | | | | | 1. MEASURES TO PRESERVE REQUIRED EXISTING CONCEALMENT | | | ELEMENTS, IF ANY, SHALL BE EMPLOYED, SUCH AS SCREENING | | | OR PAINTING OF ADDED/RELOCATED EQUIPMENT TO MATCH THE | | | BUILDING; AND | | | | | | 2. THERE SHALL BE NO VISIBLE LOGOS OR MARKINGS OF ANY | | | KIND ON VISUALLY EXPOSED AREAS; AND, | | | | | | 3. THE APPLICANT SHALL MAINTAIN MARKINGS ON THE | | | PENTHOUSE WHERE RF LEVELS EXCEED THE FCC MAXIMUM | | | PERMITTED EXPOSURE LEVELS. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-11-16 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-11-16 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2020-11-16 16:07:51 | PROVISO | | | | | | 1. MEASURES TO PRESERVE REQUIRED EXISTING CONCEALMENT | | | ELEMENTS, IF ANY, SHALL BE EMPLOYED, SUCH AS SCREENING | | | OR PAINTING OF ADDED/RELOCATED EQUIPMENT TO MATCH THE | | | BUILDING; AND | | | | | | 2. THERE SHALL BE NO VISIBLE LOGOS OR MARKINGS OF ANY | | | KIND ON VISUALLY EXPOSED AREAS; AND, | | | | | | 3. THE APPLICANT SHALL MAINTAIN MARKINGS ON THE | | | PENTHOUSE WHERE RF LEVELS EXCEED THE FCC MAXIMUM | | | PERMITTED EXPOSURE LEVELS. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2020-10-08 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2020-10-08 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2020-10-08 16:58:02 | PROVISO | | | | | | 1. MEASURES TO PRESERVE REQUIRED EXISTING CONCEALMENT | | | ELEMENTS, IF ANY, SHALL BE EMPLOYED, SUCH AS SCREENING | | | OR PAINTING OF ADDED/RELOCATED EQUIPMENT TO MATCH THE | | | BUILDING; AND | | | | | | 2. THERE SHALL BE NO VISIBLE LOGOS OR MARKINGS OF ANY | | | KIND ON VISUALLY EXPOSED AREAS; AND, | | | | | | 3. THE APPLICANT SHALL MAINTAIN MARKINGS ON THE | | | PENTHOUSE WHERE RF LEVELS EXCEED THE FCC MAXIMUM | | | PERMITTED EXPOSURE LEVELS. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. |
|
|