| 2020-12-09 13:17:57 | DECK |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) PLEASE SHOW THE AMOUNT OF #5 REBAR FOR THE FOOTINGS. |
| | 2) STAIR DRAWINGS NEEDS TO SHOW THE WIND DESIGN |
| | PARAMETERS (CODE IN AFFECT, WIND SPEED, EXPOSURE |
| | CATEGORY ETC.) TO COMPLY WITH FBC R301.2.1 ( 150 MPH |
| | MIN. WIND SPEED PER FBC WPB AMENDMENTS 120) |
| | 3) PLEASE SHOW THE DECKING PLYWOOD TYPE TO COMPLY WITH |
| | FBC R803.2.1.1 EXPOSURE DURABILITY. WOOD STRUCTURAL |
| | PANELS, WHEN DESIGNED TO BE PERMANENTLY EXPOSED IN |
| | OUTDOOR APPLICATIONS, SHALL BE OF AN EXTERIOR EXPOSURE |
| | DURABILITY. |
| | 4) PLEASE SHOW THE PLYWOOD ATTACHMENT DETAILS. |
| | 5) PLEASE SHOW THE 1X3 ATTACHMENT DETAILS. |
| | 6) PLEASE SHOW THE COMPOSITE DECKING ATTACHMENT |
| | DETAILS. |
| | 7) PLEASE CLARIFY THE BEAM TYPE ONE DRAWING SHOWS LVL |
| | BEAM THE OTHER DRAWING SHOWS 3 - 2X'S |
| | 8) PLEASE SHOW THE LVL BEAM TYPE FOR THE EXPOSED |
| | EXTERIOR LOCATION FBC - R317.1.5 |
| | 9) ON THE FRAMING DRAWINGS PLEASE SHOW THE WIND DESIGN |
| | PARAMETERS (CODE IN AFFECT, WIND SPEED, EXPOSURE |
| | CATEGORY ETC.) TO COMPLY WITH FBC R301.2.1 ( 150 MPH |
| | MIN. WIND SPEED PER FBC WPB AMENDMENTS 120) |
| | 10) PLEASE PROVIDE KNEE WALL DETAILS SHOWING ALL |
| | FRAMING SIZES AND ATTACHMENTS TO COMPLY WITH THE WIND |
| | LOADS FBC 1609 |
| | 11) PLEASE SHOW HOW THE EXISTING ROOF WILL DRAIN WHERE |
| | THE KNEE WALLS ARE BEING ADDED. |
| | 12) EACH DRAWING NEEDS TO BE SIGNED BY THE ENGINEER - |
| | ONLY THE STAIR DRAWING WAS ELECTRONICALLY SIGNED. |