Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-10-13 Cont ID  
Sent By pvalenti Date 2020-10-13 Time 10:41 Rev Time 0.00
Received By pvalenti Date 2020-10-13 Time 10:41 Sent To  
Notes
2020-10-13 10:47:21PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 1) PROVIDE DESIGNER OF RECORD REVIEW STAMPED PRODUCT
 APPROVAL FOR SLIDING GLASS DOOR.
 2) PROVIDE SIGNED/SEALED SPECIFIC DETAILS FOR TRUSS
 REPAIR INCLUDING NUMBER OF FASTENERS FOR FOR GUSSET
 PLATES.
 3) AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION
 PLEASE PROVIDE A WELD PROCEDURE SPECIFICATION; THE
 W.P.S. SPECIFIES THE REQUIRED ESSENTIAL VARIABLES
 INCLUDING: BASE MATERIALS, JOINTS, PROCESS, AND FILLER
 METALS TO BE USED.
 AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE
 PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE
 W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO
 VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS
 IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-10-13 Cont ID  
Sent By pvalenti Date 2020-10-13 Time 10:47 Rev Time 0.00
Received By pvalenti Date 2020-09-30 Time 07:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-10-02 Cont ID  
Sent By dbattles Date 2020-10-02 Time 07:58 Rev Time 0.00
Received By dbattles Date 2020-10-02 Time 07:58 Sent To  
Notes
***NONE***