| Plan Review Stops For Permit 20091091 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-16 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-16 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-09 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-08 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2020-10-09 07:46:34 | PLAN REVIEW GENERATOR / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: PRE-CAST GENERATOR PAD ENGINEERING: | | | | | | 1. THE WEIGTH OF THE PROPOSED 2020 GENERAC POWER | | | SYSTEMS, INC. MODEL G007042-3, G007043-3, 22KW | | | GENERATOR IS 445LBS. | | | | | | THE WEIGTH OF THE PROPOSED GENERAC 007042 & 7043, 22KW | | | GENERATOR REFRENCED ON THE PRE-CAST PAD ENGINEERING IS | | | 466LBS. (SEE GENERATOR TABLE) | | | | | | NOTE: THE WEIGHT OF THE GENERATOR EFFECTS THE DESIGN | | | WIND LOADS OF THE GENERATOR. THE DESIGN WIND LOADS OF | | | THE GENERATOR MUST MEET THE REQUIREMENTS OF THE | | | SITE-SPECIFIC DESIGN WIND LOADS PROVIDED. | | | (SEE WIND DESIGN REQUIREMENTS PER ASCE 7-10) | | | | | | SUBMIT NEW PRE-CAST PAD ENGINEERING USING THE WEIGHT OF | | | THE PROPOSED GENERATOR. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-13 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-13 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-24 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-24 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-05 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-05 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2020-10-05 11:42:41 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20091091 | | | | | | CODES IN EFFECT: | | | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A COPY OF THE GAS TABLES USED TO SIZE | | | THIS GAS SYSTEM. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-24 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-12 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-27 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-09-25 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-24 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-24 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-05 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-05 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-24 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-24 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-05 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-05 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-11-24 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-11-24 |
Time |
15:10 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-23 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-10-23 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-10-23 |
Time |
08:34 |
Sent To |
I |
|
| Notes |
| 2020-10-26 08:37:15 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. GENERATOR EQUIPMENT ENCROACHES TOO FAR INTO REQUIRED | | | SETBACK. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING | | | AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | | THAN 4 FEET INTO A REQUIRED SETBACK. THE REQUIRED SIDE | | | SETBACK IS 10 FEET, THEREFORE THE MINIMUM SETBACK FOR | | | THE PROPOSED GENERATOR SHOULD BE 6 FEET. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|