| Plan Review Stops For Permit 20090949 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-10-20 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-10-20 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-25 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-25 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2020-09-25 10:06:51 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) FBC B 107.2.1, PLEASE PROVIDE CONNECTION DETAILS FOR | | | THE NEW GARAGE ROOF FRAMING TO EXISTING GABLE WALL | | | FRAMING (WALL ABUTTMENT AREA). | | | 2) FBC B 107.2.1, PLEASE PROVIDE WALL CONNECTION | | | DETAILS FOR THE EXISTING TO NEW WALL FRAMING MEMBERS. | | | | | | | | | PROVISO: | | | | | | 1) AT TIME OF INSPECTION PROVIDE ROOF ENGINEERING | | | SIGNED & SEALED BY TRUSS ENGINEER AND REVIEW STAMPED BY | | | THE DESIGNER OF RECORD. | | | 2) A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO | | | INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-13 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-13 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-13 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-24 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-10-19 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-10-19 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:35:10 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | IMPACT FEE REVIEW NOT REQUIRED PER PALM BEACH COUNTY | | | (WILLIE SWOOP). |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-25 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-25 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2020-09-25 15:11:27 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | IMPACT FEE REVIEW DENIED: | | | | | | THE PLANS MAY NEED TO BE REVIEWED BY PALM BEACH COUNTY | | | FOR THEIR IMPACT FEE REVIEW. | | | AT THIS TIME I AM WAITING FOR A RESPONSE FROM THE | | | COUNTY. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-25 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-25 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-25 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-25 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2020-09-25 11:13:51 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | ROOFING REVIEW APPROVED WITH PROVISO: | | | | | | PROVIDE A ROOFING SUB-PERMIT PRIOR TO ROOF WORK. | | | | | | NOTE: THE SUBMITTED PRODUCT APPROVALS FOR THE ROOF ARE: | | | 1) ASPHALT SHINGLES, FL10124-R27 | | | 2) UNDERLAYMENT, FL10626-R18 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-25 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-25 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2020-09-25 07:59:56 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED BY SUBMITTED PAPER PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-10-06 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-10-06 |
Time |
|
Sent To |
I |
|
| Notes |
|
|