| 2020-10-07 10:12:10 | SHED |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | 1) THE SHED NEEDS TO MEET THE REQUIRED WIND LOADS PER |
| | FBC R301.2.1 - RISK CATEGORY I WIND SPEED 150MPH, |
| | EXPOSURE "C" AND CANNOT BE CODE PRESCRIPTIVE PER FBC |
| | R301.2.1.1 - PLEASE PROVIDE THE STRUCTURAL CALCULATIONS |
| | FOR THE WIND LOADS SHOWING THAT THE CONSTRUCTION |
| | DRAWINGS MEET THE REQUIRED WIND LOADS OR PROVIDE SIGNED |
| | AND SEALED CONSTRUCTION DETAILS FROM AN ARCHITECT OR |
| | ENGINEER. |
| | 2) A PRODUCT APPROVAL CAN BE PROVIDED FOR A FLORIDA |
| | STATE APPROVED PRE FAB SHED. FBC WPB AMENDMENTS 107.3 |
| | EXCEPTION (1) - ALONG WITH SIGNED AND SEALED TIEDOWN |
| | DRAWINGS FROM AN ARCHITECT OR ENGINEER. |
| | 3) BUILT ON SITE SHED DRAWINGS NEED TO SHOW ALL |
| | CONSTRUCTION DETAILS SIZE OF LUMBER, CONNECTION TYPES |
| | AND SIZES, STRAPPING, FOUNDATIONS, TIEDOWNS, ROOFING |
| | ETC. |
| | 4) PLEASE PROVIDE A SURVEY OR SITE PLAN SHOWING THE |
| | LOCATION OF THE SHED AND THE DIMENSIONS FROM THE |
| | PROPERTY LINES AND EXISTING BUILDINGS. |
| | |
| | FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO |
| | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR |
| | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - |
| | IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL |
| | SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE |
| | ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG |
| | WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON |
| | FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW |
| | REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected] |
| | AND ASKING FOR THE FORM. |