| Plan Review Stops For Permit 20090886 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2021-01-04 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2021-01-04 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-14 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-14 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-11-03 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2020-11-03 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-03 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-02 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-02 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2020-10-02 08:39:13 | WALKIN COOLER | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE A LOCATION PLAN - IS THE COOLER | | | INSIDE THE BUILDING OR OUTSIDE? | | | 2) INSIDE THE BUILDING - PLEASE PROVIDE A LIFE | | | SAFETY/FLOOR PLAN - LOCATION OF COOLER, SHOW ALL | | | BUILDING EXITS FBC CHAPTER 10, BUILDING OCCUPANCY | | | CLASSIFICATION (USE) PER FBC CHAPTER 3, SHOW ALL | | | DIMENSIONS, BUILDING CONSTRUCTION TYPE PER FBC CHAPTER | | | 6, IS THE BUILDING SPRINKLERED? | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-12-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-11 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2020-12-11 15:06:22 | ELECTRICAL PLAN NOT SIGNED JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-03 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-11-03 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2020-11-03 13:43:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PERMIT STATES WALKIN COOLER, HOOD FAN ON PLANS? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-01 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-01 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2020-10-01 13:13:34 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NO LIGHTS SWITCHES OR DISCONNECTS SHOWN FOR THE INSIDE | | | OF THE COOLERS JLEAHY | | | | | | PLEASE SUBMIT AN ELECTRICAL PLAN SHOWING LIGHTS, | | | SWITCHES AND ELECTRIC FOR COOLERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-05 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-04 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-14 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-07 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-03 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-29 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-10-02 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-23 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-05 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-05 |
Time |
15:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-08 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-12-08 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2020-12-08 09:45:35 | | | | | | | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT-20090886 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THIRD REQUEST FOR THE FOLLOWING INFORMATION: | | | | | | 1) PLEASE PROVIDE THE REQUIREMENTS FROM FBC M 1102.1 | | | COPIED BELOW. YOU MUST PROVIDE AMOUNT OF ALLOWABLE | | | REFRIGERANT. | | | 1102.1GENERAL. | | | THE SYSTEM CLASSIFICATION, ALLOWABLE REFRIGERANTS, | | | MAXIMUM QUANTITY, ENCLOSURE REQUIREMENTS, LOCATION | | | LIMITATIONS, AND FIELD PRESSURE TEST REQUIREMENTS SHALL | | | BE DETERMINED AS FOLLOWS: | | | 1. 1.DETERMINE THE REFRIGERATION SYSTEM'S | | | CLASSIFICATION, IN ACCORDANCE WITH SECTION 1103.3. | | | 2. 2.DETERMINE THE REFRIGERANT CLASSIFICATION IN | | | ACCORDANCE WITH SECTION 1103.1. | | | 3. 3.DETERMINE THE MAXIMUM ALLOWABLE QUANTITY OF | | | REFRIGERANT IN ACCORDANCE WITH SECTION 1104, BASED ON | | | TYPE OF REFRIGERANT, SYSTEM CLASSIFICATION AND | | | OCCUPANCY. | | | 4. 4.DETERMINE THE SYSTEM ENCLOSURE REQUIREMENTS IN | | | ACCORDANCE WITH SECTION 1104. | | | 5. 5.REFRIGERATION EQUIPMENT AND APPLIANCE LOCATION AND | | | INSTALLATION SHALL BE SUBJECT TO THE LIMITATIONS OF | | | CHAPTER 3. | | | 6. 6.NONFACTORY-TESTED, FIELD-ERECTED EQUIPMENT AND | | | APPLIANCES SHALL BE PRESSURE TESTED IN ACCORDANCE WITH | | | SECTION 1108. | | | | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-30 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-30 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2020-10-30 09:56:03 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT-20090886 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE REQUIREMENTS FROM FBC M 1102.1 | | | COPIED BELOW. YOU MUST PROVIDE AMOUNT OF ALLOWABLE | | | REFRIGERANT. | | | 1102.1GENERAL. | | | THE SYSTEM CLASSIFICATION, ALLOWABLE REFRIGERANTS, | | | MAXIMUM QUANTITY, ENCLOSURE REQUIREMENTS, LOCATION | | | LIMITATIONS, AND FIELD PRESSURE TEST REQUIREMENTS SHALL | | | BE DETERMINED AS FOLLOWS: | | | 1. 1.DETERMINE THE REFRIGERATION SYSTEM'S | | | CLASSIFICATION, IN ACCORDANCE WITH SECTION 1103.3. | | | 2. 2.DETERMINE THE REFRIGERANT CLASSIFICATION IN | | | ACCORDANCE WITH SECTION 1103.1. | | | 3. 3.DETERMINE THE MAXIMUM ALLOWABLE QUANTITY OF | | | REFRIGERANT IN ACCORDANCE WITH SECTION 1104, BASED ON | | | TYPE OF REFRIGERANT, SYSTEM CLASSIFICATION AND | | | OCCUPANCY. | | | 4. 4.DETERMINE THE SYSTEM ENCLOSURE REQUIREMENTS IN | | | ACCORDANCE WITH SECTION 1104. | | | 5. 5.REFRIGERATION EQUIPMENT AND APPLIANCE LOCATION AND | | | INSTALLATION SHALL BE SUBJECT TO THE LIMITATIONS OF | | | CHAPTER 3. | | | 6. 6.NONFACTORY-TESTED, FIELD-ERECTED EQUIPMENT AND | | | APPLIANCES SHALL BE PRESSURE TESTED IN ACCORDANCE WITH | | | SECTION 1108. | | | | | | 2) IT APPEARS THAT THE HOOD DRAWINGS WERE UPLOADED INTO | | | THESE REFRIGERATION PERMIT FILES, PLEASE REMOVE THEM AS | | | THEY ARE NOT PART OF THIS PERMIT. FBC 107.2 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-24 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-24 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2020-09-24 13:55:57 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20090886 | | | | | | CODES IN EFFECT: | | | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE ALL THE REQUIRED INFORMATION FROM FBC | | | M 1102.1 FOR THE WALKIN COOLER AND FREEZER. INCLUDING | | | REFRIGERANT AND TOTAL AMOUNT IN LBS. THE SYSTEM | | | REQUIRES. | | | | | | 2) PLEASE SHOW WHERE THE CU UNIT WILL BE LOCATED. FBC | | | FS 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2021-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2021-03-04 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2021-03-04 |
Time |
18:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-01-05 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-05 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-12-08 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-01-05 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2020-12-11 15:07:26 | ELECTRICAL PLAN NOT SIGNED JLEAHY | | 2020-12-08 09:50:06 | PLEASE SEE 2ND CYCLE COMMENTS: | | | | | | SHEETS A101, A103 AND THE WALKIN COOLER LAYOUT DO NOT | | | HAVE THE DIGITAL SIGNATURE OR SEAL OF THE DESIGNER. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-10-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-30 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2020-10-30 10:12:40 | SHEETS A101, A103 AND THE WALKIN COOLER LAYOUT DO NOT | | | HAVE THE DIGITAL SIGNATURE OR SEAL OF THE DESIGNER. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-24 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-24 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-10-02 |
Time |
11:07 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-10-02 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|