Plan Review Details - Permit 20090622
| Plan Review Stops For Permit 20090622 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-10 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-28 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2021-03-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-04 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-03-04 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2021-03-04 08:30:57 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-10-13 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-10-13 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-10-13 14:39:25 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN PDF | | | FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE INCLUDE | | | THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2021-07-15 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-07-15 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2021-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-06-24 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-06-24 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2021-06-24 11:16:11 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20090622 | | | ADD: 428 CLEMATIS ST. | | | CONT: FOREMOST GENERAL CONTRACTING INC. | | | TEL: 954-953-7991 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: THURS. JUNE 24TH / / 2021 | | | ACTION: DENIED | | | | | | 1) LIFE SAFETY PLAN LS1 & A2: THE OCCUPANT LOAD | | | CALCULATIONS INDICATE 32 OCCUPANTS, BUT THE PLANS KEEP | | | STATING FOR BUSINESS OCCUPANCY YOU ARE ALLOWED COMMON | | | PATH OF TRAVEL FOR BUSINESS OCCUPANCY 100 FEET MAXIMUM | | | 30 OCCUPANTS. THIS IS TAKEN FROM THE 2017 FBC-BUILDING | | | TABLE 1006.1.2. THIS IS CORRECT, BUT FOR 32 OCCUPANTS, | | | BUSINESS OCCUPANCY, NON-SPRINKLERED YOUR COMMON PATH OF | | | TRAVEL IS 75 FEET. FROM THE FURTHEST POINT IN THE | | | FURTHEST RESTROOM TO THE FRONT ENTRY IS 80 FEET WHEN | | | MEASURED TO YOUR DRAWINGS. IF YOU REDUCE YOU OCCUPANT | | | LOAD BY TWO YOUR OCCUPANT LOAD OF 30 WOULD QUALIFY FOR | | | COMMON PATH OF TRAVEL OF 100 FEET FOR A BUSINESS | | | OCCUPANCY NON-SPRINKLERED AND AN OCCUPANT LOAD OF 30. | | | | | | 2K) 4TH REQUEST. THIS COMMENT IS A RESULT OF THE | | | BUILDING OFFICIAL INTERPRETATION ON 06/2020. IN | | | BATHROOMS, RESTROOMS & SERVICE SINK AREAS EPOXY PAINT | | | IS NO LONGER CONSIDERED A SMOOTH HARD, NON-ABSORBENT | | | SURFACE. | | | EXISTING RESTROOM ELEVATIONS DO NOT PROVIDE WALL | | | FINISHES. 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION. IN RESTROOMS EPOXY PAINT IS NO LONGER | | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. WALLS | | | & PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIAL USED IN SUCH WALLS SHALL BE OF A TYPE THAT | | | IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2K)(1) FBC-B2509.1. WET AREAS. SHOWERS AND PUBLIC | | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | 2K)(2) FBC-B1210.2. FINISH MATERIALS. WALLS, FLOORS AND | | | PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH | | | SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 3) COMPLIED. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2021-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-05-10 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-05-10 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2021-05-10 08:59:55 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20090622 | | | ADD: 428 CLEMATIS ST. | | | CONT: FOREMOST GENERAL CONTRACTING INC. | | | TEL: 954-953-7991 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MON. MAY 10TH/ / 2021 | | | ACTION: DENIED | | | | | | 1) LIFE SAFETY PLAN LS1 & A2: | | | 1A) 3RD REVIEW. THIS TENANT SPACE THE DESIGNER OF | | | RECORD LABELS AS AN A2 OCCUPANCY FOR THE 3RD REVIEW. | | | PLEASE REVIEW IN THE 2017 FBC-B SECTION 303.1.2 SMALL | | | ASSEMBLY SPACES A ROOM WITH LESS THAN 750 SQ. FT. AND | | | OCCUPANT LOAD OF 50 IS TO BE CLASSIFIED AS AN BUSINESS | | | OCCUPANCY. UPDATE PLANS. | | | | | | 1B)NOTE ONLY FOR OCCUPANT LOAD DESIGN. THE OCCUPANT | | | LOAD FACTOR TAKEN FOR THE BUSINESS OCCUPANCY IS TAKEN | | | AT 100 GROSS AREA. FLOOR AREA, GROSS. THE FLOOR AREA | | | WITHIN THE INSIDE PERIMETER OF THE EXTERIOR WALLS OF | | | THE BUILDING UNDER CONSIDERATION, EXCLUSIVE OF VENT | | | SHAFTS AND COURTS, WITHOUT DEDUCTION FOR CORRIDORS, | | | STAIRWAYS, CLOSETS, THE THICKNESS OF INTERIOR WALLS, | | | COLUMNS OR OTHER FEATURES. THE FLOOR AREA OF A | | | BUILDING, OR PORTION THEREOF, NOT PROVIDED WITH | | | SURROUNDING EXTERIOR WALLS SHALL BE THE USABLE AREA | | | UNDER THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR | | | ABOVE. | | | | | | 1C)(1) ? 1C)(4) COMPLIED. | | | . | | | | | | 1C)(5) 2ND REQUEST. HAD COMPLIED. STANDING AND SEATING | | | AREA 364 SQ. FT. LESS THAN 750 SQ. FT. CONSIDERED | | | BUSINESS OCCUPANCY. 364/ 100=4 OCCUPANTS. | | | PLEASE NOTE SHEET A2 SHOWS 5 INDOOR SEATS AND 8 | | | SEASONAL SEATS. | | | | | | 1C)(6) COMPLIED. THE TOTAL OCCUPANT LOAD FOR EGRESS | | | WOULD BE 10 PLUS , BUT FOR PLUMBING FIXTURE YOU COUNT | | | THE EXTERIOR SEASONAL SEATING (8) THE OCCUPANT LOAD | | | WOULD BE 18 OCCUPANTS. IN THE 2017 FBC-B TABLE 1006.2.1 | | | SPACES WITH ONE EXIT ACCESS DOORWAY WITHOUT FIRE | | | SPRINKLERS ALLOWS 100 FEET COMMON PATH OF TRAVEL WHEN | | | THERE IS AN OCCUPANT LOAD OF 30 OR LESS. | | | | | | 1D) COMPLIED. PLEASE CORRECT WITHIN THE BLOCK LABELED | | | OCCUPANT LOAD CALCULATION THE STATEMENT READS: NUMBER | | | OF REQUIRED EXITS 2, NUMBER OF EXITS 2. | | | | | | 1E) COMPLIED. PLEASE REVIEW IN THE 2017 FBC-B TABLE | | | 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY, | | | THIS TABLE IS TO BE USED ONLY AT GRADE LEVEL!!!! FOR A | | | BUSINESS OCCUPANCY, WITHOUT SPRINKLERS, 30 OR LESS | | | OCCUPANTS THE COMMON PATH OF EGRESS TRAVEL IS 100 FT. | | | PLEASE USE THIS LANGUAGE TO CORRECT COMMENT (1D) FOR | | | CODE COMPLIANCE. | | | | | | 2) SHEET A2 THE FLOOR PLAN SHOWS SEATING AND COUNTER | | | SALES AREA & CASHIER, BUT THE PLAN DOES NOT SHOW | | | ACCESSIBLE ELEMENTS: | | | 2A) COMPLIED. | | | | | | 2B) 3RD REQUEST. THE ENTRANCE ALSO NEEDS TO SHOW | | | COMPLIANCE WITH: ACCESS. CODE 404.2.4 MANEUVERING | | | CLEARANCES. DOORS. | | | MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL | | | COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL | | | EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED | | | LATCH SIDE FOR SIDE CLEARANCE 18 INCHES. FIGURE | | | 404.2.4.1(A). | | | | | | 2C-2J) COMPLIED. | | | 2K) EXISTING RESTROOM ELEVATIONS DO NOT PROVIDE WALL | | | FINISHES. 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION. IN RESTROOMS EPOXY PAINT IS NO LONGER | | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. WALLS | | | & PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIAL USED IN SUCH WALLS SHALL BE OF A TYPE THAT | | | IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2K) 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS & | | | SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED | | | A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | | | 2K)(1) FBC-B2509.1. WET AREAS. SHOWERS AND PUBLIC | | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | 2K)(2) FBC-B1210.2. FINISH MATERIALS. WALLS, FLOORS AND | | | PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH | | | SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 2L-2N) COMPLIED. | | | | | | | | | 3) COMPLIED. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2021-03-04 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2021-03-04 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2021-03-04 09:55:52 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20090622 | | | ADD: 428 CLEMATIS ST. | | | CONT: FOREMOST GENERAL CONTRACTING INC. | | | TEL: 954-953-7991 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURS. MARCH 04TH/ / 2021 | | | ACTION: DENIED | | | | | | 1) LIFE SAFETY PLAN LS1 & A2: | | | 1A)2ND REVIEW. THIS TENANT SPACE THE DESIGNER OF RECORD | | | LABELS AS AN A2 OCCUPANCY FOR THE 2ND REVIEW. PLEASE | | | REVIEW IN THE 2017 FBC-B SECTION 303.1.2 SMALL ASSEMBLY | | | SPACES A ROOM WITH LESS THAN 750 SQ. FT. AND OCCUPANT | | | LOAD OF 50 IS TO BE CLASSIFIED AS AN BUSINESS | | | OCCUPANCY. UPDATE PLANS. | | | | | | 1B)NOTE ONLY FOR OCCUPANT LOAD DESIGN. THE OCCUPANT | | | LOAD FACTOR TAKEN FOR THE BUSINESS OCCUPANCY IS TAKEN | | | AT 100 GROSS AREA. FLOOR AREA, GROSS. THE FLOOR AREA | | | WITHIN THE INSIDE PERIMETER OF THE EXTERIOR WALLS OF | | | THE BUILDING UNDER CONSIDERATION, EXCLUSIVE OF VENT | | | SHAFTS AND COURTS, WITHOUT DEDUCTION FOR CORRIDORS, | | | STAIRWAYS, CLOSETS, THE THICKNESS OF INTERIOR WALLS, | | | COLUMNS OR OTHER FEATURES. THE FLOOR AREA OF A | | | BUILDING, OR PORTION THEREOF, NOT PROVIDED WITH | | | SURROUNDING EXTERIOR WALLS SHALL BE THE USABLE AREA | | | UNDER THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR | | | ABOVE. | | | | | | 1C)(1) COMPLIED. THE OFFICE AREA WAS TAKEN 15 GROSS. | | | PLEASE NOTE TABLE 1004.1.2 THE OCCUPANT LOAD FACTOR IS | | | TAKEN AT 100 SQ. FT./ OCCUPANT. 48 SQ. FT./ 100= 1 | | | OCCUPANT. | | | | | | 1C)(2) 2ND REQUEST. THE KITCHEN AREA IS INCREASED. | | | KITCHEN AREA CALCULATIONS IS TAKEN AT 200 GROSS (2017 | | | FBC-B TABLE 1004.1.2) MAY VARY IN THE FIRE CODES,440 | | | SQ. FT. /200= 3 OCCUPANTS NOT 2, PLEASE UPDATE THE | | | FLOOR PLAN. | | | | | | 1C)(3) COMPLIED. RESTROOM 61 SQ. FT./ 100= 1 OCCUPANT. | | | | | | 1C)(4)COMPLIED. STORAGE 6X10= 60 SQ. FT./ 300= 1 | | | OCCUPANT. | | | | | | 1C)(5) COMPLIED. STANDING AND SEATING AREA 364 SQ. FT. | | | LESS THAN 750 SQ. FT. CONSIDERED BUSINESS OCCUPANCY. | | | 364/ 100=4 OCCUPANTS. | | | PLEASE NOTE SHEET A2 SHOWS 5 INDOOR SEATS AND 8 | | | SEASONAL SEATS. | | | | | | 1C)(6) COMPLIED. THE TOTAL OCCUPANT LOAD FOR EGRESS | | | WOULD BE 10 PLUS , BUT FOR PLUMBING FIXTURE YOU COUNT | | | THE EXTERIOR SEASONAL SEATING (8) THE OCCUPANT LOAD | | | WOULD BE 18 OCCUPANTS. IN THE 2017 FBC-B TABLE 1006.2.1 | | | SPACES WITH ONE EXIT ACCESS DOORWAY WITHOUT FIRE | | | SPRINKLERS ALLOWS 100 FEET COMMON PATH OF TRAVEL WHEN | | | THERE IS AN OCCUPANT LOAD OF 30 OR LESS. | | | | | | 1D) COMPLIED. PLEASE CORRECT WITHIN THE BLOCK LABELED | | | OCCUPANT LOAD CALCULATION THE STATEMENT READS: NUMBER | | | OF REQUIRED EXITS 2, NUMBER OF EXITS 2. | | | | | | 1E) COMPLIED. PLEASE REVIEW IN THE 2017 FBC-B TABLE | | | 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY, | | | THIS TABLE IS TO BE USED ONLY AT GRADE LEVEL!!!! FOR A | | | BUSINESS OCCUPANCY, WITHOUT SPRINKLERS, 30 OR LESS | | | OCCUPANTS THE COMMON PATH OF EGRESS TRAVEL IS 100 FT. | | | PLEASE USE THIS LANGUAGE TO CORRECT COMMENT (1D) FOR | | | CODE COMPLIANCE. | | | | | | 2) SHEET A2 THE FLOOR PLAN SHOWS SEATING AND COUNTER | | | SALES AREA & CASHIER, BUT THE PLAN DOES NOT SHOW | | | ACCESSIBLE ELEMENTS: | | | 2A) COMPLIED. THE ENTRANCE NEEDS TO SHOW COMPLIANCE | | | WITH: ACCESS. CODE 404.2.5. THRESHOLDS. THRESHOLDS, IF | | | PROVIDED AT DOORWAYS, SHALL BE ? INCH HIGH MAXIMUM. | | | RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS | | | SHALL COMPLY WITH 302 & 303. | | | | | | 2B) 2ND REQUEST. THE ENTRANCE ALSO NEEDS TO SHOW | | | COMPLIANCE WITH: ACCESS. CODE 404.2.4 MANEUVERING | | | CLEARANCES. DOORS. | | | MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL | | | COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL | | | EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED | | | LATCH SIDE FOR SIDE CLEARANCE. FIGURE 404.2.4.1(A). | | | | | | 2C) COMPLIED. SHEET A2 NOR THE LIFE SAFETY SHEET SHOW | | | COMPLIANCE WITH THE 2017 FBC-ACCESSIBILITY CODE; | | | 1) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE | | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE | | | SEATING SPACES AND STANDING SPACES AT THE DINING | | | SURFACES SHALL COMPLY WITH 902. | | | | | | 2D) COMPLIED. 226.2 DISPERSION. DINING SURFACES AND | | | WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE | | | DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING | | | DINING SURFACES AND WORK SURFACES. | | | | | | 2E) COMPLIED. 206.2.5 206.2.5 RESTAURANTS AND | | | CAFETERIAS. IN RESTAURANTS AND CAFETERIAS, AN | | | ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL DINING AREAS, | | | INCLUDING RAISED OR SUNKEN DINING AREAS, AND OUTDOOR | | | DINING AREAS. | | | | | | 2F) COMPLIED. 902.1. DINING SURFACES AND WORK SURFACES | | | SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 | | | GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT LIMITED | | | TO, BARS, TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES | | | OF WORK SURFACES INCLUDE WRITING SURFACES, STUDY | | | CARRELS, STUDENT LABORATORY STATIONS, BABY CHANGING AND | | | OTHER TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON | | | COUNTERS, AND WHERE COVERED BY THE ADA SCOPING | | | PROVISIONS, EMPLOYEE WORK STATIONS. | | | | | | 2F)(1) COMPLIED. 902.2 CLEAR FLOOR OR GROUND SPACE. A | | | CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A | | | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE | | | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 2F)(2) COMPLIED.902.3 HEIGHT. THE TOPS OF DINING | | | SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM | | | AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2G) 2ND REQUEST. THE TOPS OF WORK SURFACES SHALL BE 28 | | | INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2H) COMPLIED. SHOW COMPLIANCE WITH THE ACCESS. CODE | | | 305.5 POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR | | | OR GROUND SPACE SHALL BE POSITIONED FOR EITHER A | | | FORWARD OR PARALLEL APPROACH TO AN ELEMENT. | | | | | | 2I) 2ND REQUEST. 904.4 SALES AND SERVICE COUNTERS. | | | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH | | | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE | | | COUNTERTOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR | | | SERVICE COUNTERTOP. | | | | | | 2J) 2ND REQUEST. (1) 2017 FBC-ACCESSIBILITY CODE. 211.2 | | | MINIMUM NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS | | | SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY | | | WITH 602.1 THROUGH 602.6 AND ONE DRINKING FOUNTAIN | | | SHALL COMPLY WITH 602.7. | | | | | | 2J)(2) 2ND REQUEST. PROTRUDING OBJECTS 307.2 PROTRUSION | | | LIMITS 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 | | | INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR | | | SHALL NOT PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO | | | THE CIRCULATION PATH. | | | | | | 2J)(3) 2ND REQUEST. 602.2 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A | | | FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING | | | WITH 306 SHALL BE PROVIDED. | | | | | | 2K) EXISTING RESTROOM ELEVATIONS DO NOT PROVIDE WALL | | | FINISHES. 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION. IN RESTROOMS EPOXY PAINT IS NO LONGER | | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. WALLS | | | & PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIAL USED IN SUCH WALLS SHALL BE OF A TYPE THAT | | | IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2K)(1) FBC-B2509.1. WET AREAS. SHOWERS AND PUBLIC | | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | 2K)(2) FBC-B1210.2. FINISH MATERIALS. WALLS, FLOORS AND | | | PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH | | | SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 2L-2M) COMPLIED. | | | | | | 2N) 2ND REQUEST. 603.3 MIRRORS. 2017 FBC-ACCESSIBILITY | | | CODE. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS | | | SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE | | | REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 3) NEW COMMENT. THE LS-1 AND A-2 FLOOR PLAN SHOW A RAMP | | | THE HEIGHT AND SLOPE OF THE RAMP ARE NOT GIVEN SHOW | | | COMPLIANCE WITH THE 2017 FBC-B SECTIONS: | | | 3A) 1012.2 SLOPE. | | | | | | 3B) 1012.5 MINIMUM DIMENSIONS. THE MINIMUM DIMENSIONS | | | OF MEANS OF EGRESS RAMPS SHALL COMPLY WITH SECTIONS | | | 1012.5.1 | | | THROUGH 1012.5.3. 1012.5.1 WIDTH AND CAPACITY. THE | | | MINIMUM WIDTH AND REQUIRED CAPACITY OF A MEANS OF | | | EGRESS RAMP SHALL BE NOT LESS THAN THAT REQUIRED FOR | | | CORRIDORS BY SECTION 1020.2. THE CLEAR WIDTH OF A RAMP | | | BETWEEN HANDRAILS, IF PROVIDED, OR OTHER PERMISSIBLE | | | PROJECTIONS SHALL BE 36 INCHES MINIMUM. | | | | | | 3C) 1012.6 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE | | | BOTTOM AND TOP OF EACH RAMP, POINTS OF TURNING, | | | ENTRANCE, EXITS AT | | | DOORS AND IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, | | | ACCESSIBILITY. LANDINGS SHALL COMPLY WITH SECTIONS | | | 1012.6.1 | | | THROUGH 1012.6.5. | | | | | | (152 MM) SHALL HAVE HANDRAILS ON BOTH SIDES. HANDRAILS | | | SHALL COMPLY WITH SECTION 1014. 1012.9 GUARDS. GUARDS | | | SHALL BE PROVIDED WHERE REQUIRED BY SECTION 1015 AND | | | SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 1015. | | | | | | 3D) 1012.10 EDGE PROTECTION. EDGE PROTECTION COMPLYING | | | WITH SECTION 1012.10.1 OR 1012.10.2 SHALL BE PROVIDED | | | ON EACH | | | SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. | | | | | | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2020-10-13 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2020-10-13 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2020-10-13 16:31:03 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 20090622 | | | ADD: 428 CLEMATIS ST. | | | CONT: FOREMOST GENERAL CONTRACTING INC. | | | TEL: 954-953-7991 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. OCT. 13TH/ 2020 | | | ACTION: DENIED | | | | | | 1) LIFE SAFETY PLAN LS1: | | | 1A) THIS SPACE THE DESIGNER OF RECORD LABELS AS A | | | BUSINESS OCCUPANCY. I AGREE. THE DESIGNER OF RECORD | | | ALSO STATES THAT THERE IS NO CHANGE IN OCCUPANCY OR USE | | | SINCE THE SPACE IS VACANT CURRENTLY. PLEASE NOTE THIS | | | IS A CHANGE OF OCCUPANCY. | | | THIS TENANT SPACE WAS PART OF THE MAC FABRIC MERCANTILE | | | STORE THE ADDRESS 426 CLEMATIS ST. WHEN SUFFOLK | | | CONSTRUCTION CAME IN AND REMODELED THE TENANT SPACE OF | | | 426 CLEMATIS ST. THE TENANT SEPARATION WALL WENT UP | | | CREATING THE 428 CLEMATIS ST. IT CAN BE ARGUED THAT THE | | | NEW TENANT SPACE CREATED AT 428 CLEMATIS WAS LEFT AS A | | | VANILLA SHELL, BUT THE LAST KNOWN USE OCCUPATIONAL | | | LICENSE/ BUSINESS TAX WAS MAC FABRIC. THE ADDRESS OF | | | 426 THE BUSINESS TAX LICENSE IS FOR SUFFOLK | | | CONSTRUCTION, THEIR OFFICE. THE 2017 EXISTING BUILDING | | | CODE SECTION 1001.2.2.1 LIST THIS TENANT SPACE AS A | | | PARTIAL CHANGE OF OCCUPANCY. WHERE A PORTION OF THE | | | EXISTING BUILDING IS CHANGED. | | | | | | 1B) THE OCCUPANT LOAD FACTOR TAKEN FOR THE BUSINESS | | | OCCUPANCY IS TAKEN AT 100 GROSS AREA. FLOOR AREA, | | | GROSS. THE FLOOR AREA WITHIN THE INSIDE PERIMETER OF | | | THE EXTERIOR WALLS OF THE BUILDING UNDER CONSIDERATION, | | | EXCLUSIVE OF VENT SHAFTS AND COURTS, WITHOUT DEDUCTION | | | FOR CORRIDORS, STAIRWAYS, CLOSETS, THE THICKNESS OF | | | INTERIOR WALLS, COLUMNS OR OTHER FEATURES. THE FLOOR | | | AREA OF A BUILDING, OR PORTION THEREOF, NOT PROVIDED | | | WITH SURROUNDING EXTERIOR WALLS SHALL BE THE USABLE | | | AREA UNDER THE HORIZONTAL PROJECTION OF THE ROOF OR | | | FLOOR ABOVE. | | | | | | 1C)(1) THE OFFICE AREA WAS TAKEN 15 GROSS. PLEASE NOTE | | | TABLE 1004.1.2 THE OCCUPANT LOAD FACTOR IS TAKEN AT 100 | | | SQ. FT./ OCCUPANT. 48 SQ. FT./ 100= 1 OCCUPANT. | | | | | | 1C)(2) KITCHEN AREA NOT IN YOUR CALCULATIONS IS TAKEN | | | AT 200 GROSS (2017 FBC-B TABLE 1004.1.2) MAY VARY IN | | | THE FIRE CODES, 8X65= 520 SQ. FT. /200= 3 OCCUPANTS. | | | | | | 1C)(3) RESTROOM 61 SQ. FT./ 100= 1 OCCUPANT. | | | | | | 1C)(4) STORAGE 8X10= 80 SQ. FT./ 300= 1 OCCUPANT. | | | | | | 1C)(5) STANDING AND SEATING AREA 615 SQ. FT. LESS THAN | | | 750 SQ. FT. CONSIDERED BUSINESS OCCUPANCY. 615/ 100=7 | | | OCCUPANTS. | | | PLEASE NOTE SHEET A2 SHOWS 15 INDOOR SEATS AND 8 | | | SEASONAL SEATS. | | | | | | 1C)(6) TOTAL OCCUPANCY 13 OCCUPANTS. BUSINESS OCCUPANCY | | | BY THE MATH METHOD, BUT SHEET A2 SHOWS 15 SEATS + 6 | | | FROM (BUSINESS, RESTROOM, KITCHEN, OFFICE & STORAGE) = | | | 21 STILL LESS THAN 30 OCCUPANTS ALLOWING A SINGLE EXIT | | | AT 100 FEET. WOULD RECOMMEND POSTING A PLACARD FOR 30 | | | OR LESS OCCUPANTS NEAR THE EXIT. 2017 FBC-B 1004.3. | | | | | | | | | | | | | | | 1D) PLEASE CORRECT WITHIN THE BLOCK LABELED OCCUPANT | | | LOAD CALCULATION THE STATEMENT READS: NUMBER OF | | | REQUIRED EXITS 2, NUMBER OF EXITS 2. | | | | | | 1E) PLEASE REVIEW IN THE 2017 FBC-B TABLE 1006.2.1 | | | SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY, THIS TABLE | | | IS TO BE USED ONLY AT GRADE LEVEL!!!! FOR A BUSINESS | | | OCCUPANCY, WITHOUT SPRINKLERS, 30 OR LESS OCCUPANTS THE | | | COMMON PATH OF EGRESS TRAVEL IS 100 FT. PLEASE USE THIS | | | LANGUAGE TO CORRECT COMMENT (1D) FOR CODE COMPLIANCE. | | | | | | 2) SHEET A2 THE FLOOR PLAN SHOWS SEATING AND COUNTER | | | SALES AREA & CASHIER BUT THE PLAN DOES NOT SHOW | | | ACCESSIBLE ELEMENTS: | | | 2A) THE ENTRANCE NEEDS TO SHOW COMPLIANCE WITH: ACCESS. | | | CODE 404.2.5. THRESHOLDS. THRESHOLDS, IF PROVIDED AT | | | DOORWAYS, SHALL BE ? INCH HIGH MAXIMUM. RAISED | | | THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL | | | COMPLY WITH 302 & 303. | | | | | | 2B) THE ENTRANCE ALSO NEEDS TO SHOW COMPLIANCE WITH: | | | ACCESS. CODE 404.2.4 MANEUVERING CLEARANCES. DOORS. | | | MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL | | | COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL | | | EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED | | | LATCH SIDE FOR SIDE CLEARANCE. FIGURE 404.2.4.1(A). | | | | | | 2C) SHEET A2 NOR THE LIFE SAFETY SHEET SHOW COMPLIANCE | | | WITH THE 2017 FBC-ACCESSIBILITY CODE; | | | 1) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE | | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE | | | SEATING SPACES AND STANDING SPACES AT THE DINING | | | SURFACES SHALL COMPLY WITH 902. | | | | | | 2D) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES | | | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 2E) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN | | | RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL | | | BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR | | | SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS. | | | | | | 2F) 902.1. DINING SURFACES AND WORK SURFACES SHALL | | | COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL. | | | DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, | | | TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK | | | SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, | | | STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER | | | TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON | | | COUNTERS, AND WHERE COVERED BY THE ADA SCOPING | | | PROVISIONS, EMPLOYEE WORK STATIONS. | | | | | | 2F)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 2F)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2G) THE TOPS OF WORK SURFACES SHALL BE 28 INCHES (710 | | | MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE | | | FINISH FLOOR OR GROUND. | | | | | | 2H) SHOW COMPLIANCE WITH THE ACCESS. CODE 305.5 | | | POSITION. UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR | | | GROUND SPACE SHALL BE POSITIONED FOR EITHER A FORWARD | | | OR PARALLEL APPROACH TO AN ELEMENT. | | | | | | 2I) 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS | | | AND SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR | | | 904.4.2. THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL | | | EXTEND THE SAME DEPTH AS THE SALES OR SERVICE | | | COUNTERTOP. | | | | | | 2J) (1) 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM | | | NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE | | | PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 | | | THROUGH 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY | | | WITH 602.7. | | | | | | 2J)(2) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS | | | 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES | | | AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT | | | PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE | | | CIRCULATION PATH. | | | | | | 2J)(3) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE | | | COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH, | | | AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE | | | PROVIDED. | | | | | | 2K) EXISTING RESTROOM ELEVATIONS DO NOT PROVIDE WALL | | | FINISHES. 2017 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION. IN RESTROOMS EPOXY PAINT IS NO LONGER | | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. WALLS | | | & PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 4 | | | FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, | | | THE MATERIAL USED IN SUCH WALLS SHALL BE OF A TYPE THAT | | | IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 2K)(1) FBC-B2509.1. WET AREAS. SHOWERS AND PUBLIC | | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | 2K)(2) FBC-B1210.2. FINISH MATERIALS. WALLS, FLOORS AND | | | PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH | | | SECTIONS 1210.1 THROUGH 1210.4. | | | | | | 2L) PLEASE REVIEW THE DIMENSIONING HEIGHT OF GRAB BARS, | | | NOT CENTERLINE. 2017 FBC-ACCESSIBILITY CODE SECTION | | | 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE, NOT CENTERLINE. | | | | | | 2M) TOILET PAPER DISPENSERS. 604.7. THE TOILET PAPER | | | DISPENSER SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES | | | MINIMUM TO 9 INCHES MAXIMUM IN FRONT OF THE WATER | | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. | | | | | | 2N) 603.3 MIRRORS. 2017 FBC-ACCESSIBILITY CODE. MIRRORS | | | LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE | | | INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | | | | 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID | | | 19 | | | IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS | | | 561-718-9724. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2021-07-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-07-12 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-07-12 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2021-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-05-18 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-05-18 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2021-03-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-03-18 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-03-18 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-21 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-21 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2020-10-21 15:48:52 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) SIGN CURCUIT MISSING FROM LOADS | | | | | | SIGN AND OUTLINE LIGHTING. SIGN AND OUTLINE LIGHTING | | | OUTLETS SHALL BE CALCULATED AT A MINIMUM OF 1200 | | | VOLT-AMPERES FOR EACH REQUIRED BRANCH CIRCUIT SPECIFIED | | | IN 600.5(A | | | | | | 2) SHOW WINDOW OUTLETS MISSING. | | | | | | SHOW WINDOWS. SHOW WINDOWS SHALL BE CALCULATED IN | | | ACCORDANCE WITH EITHER OF THE FOLLOWING: (1) THE UNIT | | | LOAD PER OUTLET AS REQUIRED IN OTHER PROVISIONS OF THIS | | | SECTION (2) AT 200 VOLT-AMPERES PER 300 MM (1 FT) OF | | | SHOW WINDOW | | | | | | 3) RISER DIAGRAM REQUIRED TO SHOW SIZE OF MAIN 215.5 | | | | | | PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC 215.5; | | | FBC 107.2.1 | | | | | | 4) AIC RATING OF MAIN AND PANEL BREAKERS PER 110.9, | | | 110,10 LABEL REQUIRED BY 110.24 | | | | | | PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT CURRENT | | | AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE. NEC | | | 110.10 | | | | | | 5) LOADS LISTED AS DISPENSER IN THE KITCHEN AREA? GFCI | | | PROTECTION. | | | | | | 6) LIGHTING CONTROL PER FBC ENERGY CONDERVATION CODE | | | | | | PROVIDE LIGHTING CONTROL PER FBC ENERGY CODE. FBC CE | | | 405.2.2.2 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2021-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-07-15 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2021-06-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-06-23 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-04-29 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2021-03-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2021-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2021-03-03 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2021-03-03 14:58:33 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET LS 1 - THE REVISED OCCUPANCY LOAD CALCULATION | | | FOR THE STANDING/SEATING AREA IS INCORRECT PER THE FFPC | | | NFPA 101. | | | | | | PER TABLE 7.3.1.2 THE OCCUPANCY LOAD FACTOR IS 15. | | | 364/15= 24.2666 ROUNDED UP TO 25; TOTAL 30. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-22 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2020-09-22 14:45:57 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET LS 1 - THERE IS INDICATION OF PROPOSED | | | OCCUPANCY AS BUSINESS. | | | | | | PER NFPA 101, CH 3 DEFINITIONS - THIS WILL BE | | | CONSIDERED AN ASSEMBLY OCCUPANCY. BASED ON THE PROPOSED | | | SEATING AREA OF 968 AND 15SQ FT/PERSON EQUALS 65 | | | PEOPLE. | | | | | | 3.3.190.2* ASSEMBLY OCCUPANCY. AN OCCUPANCY (1) USED | | | FOR A | | | GATHERING OF 50 OR MORE PERSONS FOR DELIBERATION, | | | WORSHIP, | | | ENTERTAINMENT, EATING, DRINKING, AMUSEMENT, AWAITING | | | TRANSPORTATION, OR SIMILAR USES; OR (2) USED AS A | | | SPECIAL | | | AMUSEMENT BUILDING, REGARDLESS OF OCCUPANT LOAD. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 2) SHEET LS 1 - ONE EXIT IS INDICATED WITH A TRAVEL | | | DISTANCE OF 89'10". | | | | | | PER NFPA 101 CH 12 NEW ASSEMBLY OCCUPANCY | | | | | | 12.2.4* NUMBER OF MEANS OF EGRESS. | | | 12.2.4.1 THE NUMBER OF MEANS OF EGRESS SHALL BE IN | | | ACCORDANCE | | | WITH SECTION 7.4, OTHER THAN EXITS FOR FENCED OUTDOOR | | | ASSEMBLY | | | OCCUPANCIES IN ACCORDANCE WITH 12.2.4.4. | | | | | | 7.4* NUMBER OF MEANS OF EGRESS. | | | 7.4.1 GENERAL. | | | 7.4.1.1 THE NUMBER OF MEANS OF EGRESS FROM ANY BALCONY, | | | MEZZANINE, STORY, OR PORTION THEREOF SHALL BE NOT LESS | | | THAN TWO, | | | EXCEPT UNDER ONE OF THE FOLLOWING CONDITIONS: | | | (1) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED WHERE | | | PERMITTED | | | IN CHAPTERS 11 THROUGH 43. | | | (2) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED FOR A | | | MEZZANINE | | | OR BALCONY WHERE THE COMMON PATH OF TRAVEL LIMITATIONS | | | OF | | | CHAPTERS 11 THROUGH 43 ARE MET. | | | | | | A SINGLE EXIT IS MOT PERMITTED IN CH 12 | | | | | | PLEASE REVIEW AND CORRECT | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
P |
Date |
2021-07-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-14 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2021-07-13 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2021-06-22 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-05-26 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-04-28 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-25 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-01 |
Time |
06:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2021-01-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-10-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-09-18 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2021-07-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-08 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-08 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2021-05-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-05-14 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2021-05-14 10:18:32 | THE ORIGINAL MECHANICAL DRAWING SHOWED THE DUCT SIZES | | | AND CFM'S AT EACH GRILLE. PLEASE PROVIDE THIS | | | INFORMATION ON THE LATEST DRAWING. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2021-03-25 10:55:52 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-20090622 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) LS1 LISTS 5 AREAS IN THIS TENANT SPACE, PLEASE | | | PROVIDE OUTDOOR AIR CALCULATIONS FOR EACH USE OF SPACE | | | IN THIS TENANT SPACE. FBC M 403.3.1.1 & TABLE 403.3.1.1 | | | | | | 2) PLEASE PROVIDE AN EXPLANATION OF THE USE OF THIS | | | TENANT SPACE, IS THERE TO BE ANY COOKING IN THE | | | KITCHEN? FBC 107.2.1 | | | | | | 3) SHEET M1: PLEASE INCLUDE THE MECHANICAL DRAWING THAT | | | WAS REMOVED IN THE LATEST REVISION OF THIS SHEET. FBC | | | 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-10-13 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-10-13 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2020-10-13 13:59:21 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20090622 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE OCCUPANT LOAD OF THIS NEW RETAIL | | | SPACE. FBC M TABLE 403.3.1.1 | | | | | | 2) PLEASE PROVIDE THE SQUARE FOOTAGE OF THIS RETAIL | | | SPACE SO THAT WE CAN USE TABLE 403.3.1.1 OF THE FBC M | | | FOR VENTILATION CALCULATIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2021-07-28 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-07-28 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-07-28 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2021-07-28 10:40:11 | 07/28/21 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2021-07-13 |
|
|
Cont ID |
|
| Sent By |
abelisle |
Date |
2021-07-13 |
Time |
3:00 |
Rev Time |
0.00 |
| Received By |
abelisle |
Date |
2021-07-13 |
Time |
2:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2021-05-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2021-05-26 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2021-05-26 |
Time |
05:47 |
Sent To |
|
|
| Notes |
| 2021-05-26 06:34:20 | 1) SHT. A-2 - LABEL THE EQUIPMENT ON THE EQUIPMENT | | | SCHEDULE. THE PLAN SHOWS LETTERS FOR EACH PIECE OF | | | EQUIPMENT. WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) SHT. A-1 - THE CODE COMPLIANCE TABLE LISTS THIS | | | OCCUPANCY AS B BUT THE CODE COMPLIANCE TABLE ON SHT. | | | LS-1 LISTS THE OCCUPANCY AS AN A-2. CLARIFY. | | | 3) SINCE THE OCCCUPANT LOAD IS NOW OVER 15, TWO TOILET | | | ROOMS WILL BE REQUIRED PER FBC-PLUMBING SEC.403.2. | | | 4) SHT. P-1 - THE TOILET ROOM FLOOR PLAN SHOWS THE | | | CENTER OF THE LAVATORY AT 1 FOOT FROM THE SIDE WALL. A | | | MINIMUM OF 15 INCHES IS REQUIRED PER FBC-PLUMBING | | | SEC.405.3.1. | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | TANKLESS WATER HEATER. WPB AMEND. TO FBC SEC. 107.2.1. | | | 6) SIZE ALL SECTIONS OF THE WATER RISER. OVERHEAD | | | SECTIONS ARE MISSING SIZES. | | | 7) THE MOP SINK IS NOT VENTED. FBC-PLUMBING SEC.901.2. | | | 8) THHE PREP SINK SHALL BEE INDIRECTLY WASTED. | | | FBC-PLUMBING SEC.802.1.8. | | | 9) SUBMIT SIZING CALCULATIONS FOR THE GREASE | | | INTERCEPTOR PER FBC-PLUMBING SEC.1003.2. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2021-03-25 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2021-03-25 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2021-03-25 13:32:46 | 03/25/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | | | | | | | 1. PLEASE PROVIDE DETAILS FOR THE ACCESSIBILITY | | | RESTROOM AS FOLLOW; | | | A. THE PLANS SHOW NEW WALLS FOR THE TOILET ROOM. SINCE | | | NEW WALLS WILL BE CONSTRUCTED THE GRAB BARS WILL HAVE | | | TO MEET THE REQUIREMENTS FOR NEW CONSTRUCTION. PLEASE | | | SHOW THE HEIGHT OF THE GRAB BARS THAT SHALL BE LOCATED | | | 33-36 INCHES ABOVE THE FINISH FLOOR MEASURED TO THE TOP | | | OF THE GRIPPING SURFACE PER THE 2020 FBC-ACCESSIBILITY | | | SEC. 609.4. | | | | | | B. PLEASE GIVE DIMENSIONS FOR FIXTURE CLEARANCES FOR | | | LAV AND TOILET PER THE 2020 FBC ACC SEC. 606.2. 2 CLEAR | | | FLOOR SPACE. THE CLEAR FLOOR SPACE SHALL BE 60? INCHES | | | MINIMUM MEASURED PERPENDICULAR FROM THE SIDEWALL AND | | | 56? INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR | | | WALL PER THE 2017 FBC ACC. SEC. 604.3.1. | | | | | | C. MIRRORS SHALL BE LOCATED WITH THE BOTTOM EDGE OF THE | | | REFLECTING SURFACE 40 INCHES? MAXIMUM ABOVE THE FINISH | | | FLOOR 2020 FBC-ACCESS. SEC.603.3. | | | | | | D. PLEASE SHOW THE LOCATION OF THE GRAB BARS THAT SHALL | | | COMPLY WITH 2020 FBC-ACCESS. SECS.604.5.1, 604.5.2. | | | | | | E. PLEASE PROVIDE THE KNEE AND TOE CLEARANCES FOR THE | | | LAVATORY PER THE 2020 FBC ACC SEC. 306.1 TOE CLEARANCE. | | | | | | F. PROVIDE LAVS HEIGHT OF 34? INCHES MAXIMUM PER THE | | | 2020 FBC ACC SEC. 606.3. | | | | | | G. THE TOILET PAPER DISPENSERS SHALL BE 7? INCHES | | | MINIMUM AND 9? INCHES MAXIMUM IN FRONT OF THE WATER | | | CLOSET MEASURED TO THE CENTERLINE OF DISPENSER PER THE | | | 2017 FBC ACC SEC. 604.7. | | | | | | H. SHOW THE FLUSH CONTROLS FOR THE WATER CLOSET. THE | | | FLUSH CONTROLS SHALL COMPLY WITH FBC-ACCESS. SEC. | | | 604.6. HANDICAP CAP WATER CLOSET FLUSH CONTROL SHALL BE | | | HAND OPERATED OR AUTOMATIC AND SHALL BE 36? INCHES | | | MAXIMUM ABOVE THE FINISH FLOOR AND ON THE OPEN SIDE PER | | | THE 2017 FBC ACC SEC. 604.9.5. | | | | | | I. THE FAUCET SHALL COMPLY WITH FBC-ACCESS. SEC.606.4, | | | 309. | | | | | | K. LAVATORY WATER SUPPLY AND DRAINPIPES UNDER SIDE | | | SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT | | | AGAINST CONTACT PER THE 2017 FBC ACC SEC. 606.5. | | | | | | L. THE TOILET SEATS NEED TO BE 17? INCHES TO 19? INCHES | | | MAXIMUM MEASURED TO THE TOP OF THE SEAT PER THE 2017 | | | FBC ACC SEC. 604.4 SEATS. | | | | | | 2. THE FLOOR DRAIN IN THE TOILET ROOM CANNOT DISCHARGE | | | TO THE GREASE INTERCEPTOR PER THE 2020 FBC-PLUMBING | | | SEC. 1003.2. | | | | | | 3. SUBMIT SPECIFICATIONS/DETAILS ON THE TYPE OF GREASE | | | INTERCEPTOR TO BE INSTALLED AND MANUFACTURER'S | | | SPECIFICATIONS AND SIZING CALCULATIONS FOR THE GREASE | | | INTERCEPTOR PER THE 2020 FBC-PLUMBING SEC. 1003.2. | | | | | | 4. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE YOGURT | | | MACHINES PER THE WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | 5. THE TRAP SEAL IN THE FLOOR DRAINS SHALL BE PROTECTED | | | PER THE 2020 FBC-PLUMBING SEC.1002.4.1. | | | | | | 6. THE GREASE INTERCEPTOR SHALL HAVE A SAMPLING PORT ON | | | THE DISCHARGE SIDE OF THE INTERCEPTOR. A 4-INCH TWO-WAY | | | CLEANOUT WILL SUFFICE, SHOW THIS ON THE RISER DIAGRAM | | | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 7. PLEASE PROVIDE UNDER CODES, THE YEAR, PLUMBING AND | | | ACCESSIBILITY REFERENCED USED PER THE WPB AMENDMENTS TO | | | THE FBC SEC. 101.4 REFERENCED CODES. | | | | | | 8. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL | | | SHALL BE NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE | | | 2020 FBC BUILDING SEC. 1210.2.2 AND 2017 FBC SEC. P | | | 310.3. PLEASE MAKE A NOTE ON THIS SHEET. | | | | | | 9. ON SHEET A2, THERE IS A DETAIL WITH DIFFERENT | | | APPLIANCES AND NO REFERENCE OR NUMBERS TO THEM. IF ANY | | | OF THESE ARE A COFFEE MAKER/ICE MAKER REQUIRE AN INLINE | | | VACUUM BREAKER THAT COMPLIES WITH THE ASSE 1024 | | | NON-CARBONATED. | | | | | | 10. PLEASE PROVIDE HOT WATER AND COLD THAT ARE NOT SHOW | | | AND ITS SOURCE, SIZING, DISTRIBUTION, WATER HAMMER, | | | WITHIN ACCORDANCE 2017 FBC P SEC. 604, PLEASE PROVIDE A | | | LAYOUT AND RISER WPB AMENDMENTS TO THE FBC 107.5.1.3 | | | (13) PLUMBING RISER DIAGRAM REQUIRED. | | | | | | 11. IN THE KITCHEN AREA THERE IS A THREE-COMPARTMENT | | | SINK PLEASE PROVIDE DETAIL ON THE DRAINS TO AN INDIRECT | | | WASTE INDEPENDENTLY FORM EACH OTHER PER THE 2017 FBC | | | SEC. P 802.1.1. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2020-10-05 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2020-10-05 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2020-10-05 10:54:51 | 1) THE PLANS SHOW NEW WALLS FOR THE TOILET ROOM.SINCE | | | NEW WALLS WILL BE CONSTRUCTED THE GRAB BARS WILL HAVE | | | TO MEET THE REQUIREMENTS FORNEWCONSTRUCTION. | | | 2) THE HEIGHT OF TE GRAB BARS SHALL BE LOCATED 33-36 | | | INCHES ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | | THE GRIPPING SURFAE PER FBC-ACCESSIBILITY SEC. 609.4. | | | 3) MIRRORS SHALL BE LOCATED WITH THE BOTTOM EDGE OF THE | | | REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH | | | FLOOR. FBC-ACCESS. SEC.603.3. | | | 4) THE LOCATION OF THE GRAB BARS SHALL COMPLY WITH | | | FBC-ACCESS. SECS.604.5.1, 604.5.2. | | | 5) THE LOCATION OF THE TOILET PAPER DISPNSER SHALL | | | COMPLY WITH FBC-ACCESS. SEC. 604.7. | | | 6) SHOW THE FLUSH CONTROLS FOR THE WATER CLOSET. THE | | | FLUSH CONTROLS SHALL COMPLY WITH FBC-ACCESS. SEC. | | | 604.6. | | | 7) THE FAUCET SHALL COMPLY WITH FBC-ACCESS. SEC.606.4, | | | 309. | | | 8) THE FLOOR DRAIN IN THE TOILET ROOM CANNOT DISHARGE | | | TO THE GREASE INTERCEPTOR.FBC-PLUMBING SEC. 1003.2. | | | 9) SUBMIT MANUFACTURER'S SPECIFICATIONS AND SIZING | | | CALCULATIONS FOR THE GREASE INTERCEPTOR. FBC-PLUMBING | | | SEC. 1003.2. | | | 10) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE YOGURT | | | MACHINES.WPB AMEND. TO FBC SEC. 107.2.1. | | | 11) THE TRAP SEAL IN THE FLOOR DRAINS SHALL BE | | | PROTECTED PER FBC-PLUMBING SEC.1002.4.1. | | | 12) THE GREASE INTERCEPTOR SHALLL HAVE A SAMPLING PORT | | | ON THE DISCHARGE SIDE OF THE INTERCEPTOR. A 4-INCH | | | TWO-WAY CLEANOUT WILL SUFFICE. SHOW THIS ON THE RISER | | | DIAGRAM. | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2021-07-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-07-14 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-07-14 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2021-07-14 16:35:36 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2021-06-23 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-06-23 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-06-23 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2021-04-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-04-29 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-04-29 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2021-04-29 06:34:39 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE. ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2021-03-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-25 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-25 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2021-03-25 10:58:57 | PLEASE PROVIDE ORIGINAL DIGITALLY SIGNED AND SEALED | | | DRAWINGS THROUGH YOUR PORTAL OR PROVIDE THE ORIGINAL | | | SIGNED AND SEALED PAPER DRAWINGS TO OUR OFFICE. | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE | | | WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE | | | CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET | | | MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL | | | TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2021-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2021-03-01 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2021-03-01 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2021-03-01 15:10:28 | ORIGINAL SIGNED AND SEALED PAPER DRAWINGS ROUTED TO | | | STORAGE.ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-10-20 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-10-20 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2020-10-20 14:09:41 | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | FOR NEXT SUBMISSION: | | | | | | FS471, FS481, DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS. A SCAN OF A SIGNED | | | PLAN IS NOT CONSIDERED AN ORIGINAL. | | | | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL (OR DROP OFF) ONE ORIGINAL | | | SIGNED AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE | | | TO: | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | DEVELOPMENT SERVICES | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6746. | | | |
|
|
|