| Plan Review Stops For Permit 20090598 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-06 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2021-01-06 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2021-01-07 15:27:14 | PARKING SPACES WITH CAR CHARGES APPROVED FOR LUCID | | | MOTORS USE ONLY. NOT FOR PUBLIC USE. SEE COPY OF ZONING | | | COMMENTS BELOW. | | | | | | 12/23/20- PASSED | | | 1) THE LUCID INVENTORY PARKING/CHARGING IS NOT APPROVED | | | FOR THE PUBLIC (LUCID CAR OWNERS) ACCESS/CHARGING; AND | | | CUSTOMERS ARE NOT PERMITTED TO BE BROUGHT TO THIS AREA | | | BY SALESMEN TO REVIEW CARS THAT ARE NOT IN THE | | | SHOWROOM, BEING ATEST DRIVE, ETC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2020-12-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-22 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-22 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2020-12-22 16:17:28 | BUILDING REVIEW COMMENTS: | | | | | | 1-DISCUSSED THE REVISED PLANS WITH ROBERT BROWN | | | (BUILDING OFFICIAL). HE SAID, REVISED PLANS WILL BE OK | | | WITH LETTER FROM LUCID MOTORS CLARIFYING OVERALL | | | OPERATIONS. WHO WILL THE ONLY PEOPLE TO HAVE ACCESS TO | | | THESE PARKING SPACES AND WHAT WOULD BE THEIR SPECIFIC | | | FUNCTION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-08 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-08 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-28 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-27 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2020-10-27 13:38:52 | SECOND BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | ORIGINAL COMMENT: | | | 1- PROPOSED PARKING SPACES WITH CAR CHARGES DON'T | | | PROVIDE ANY INFORMATION SHOWING COMPLIANCE WITH THE FBC | | | ACCESSIBILITY CODE. IS THERE ANY PARKING SPACE WITH A | | | CAR CHARGER ASSIGNED FOR HANDICAPPED PEOPLE?. IS THERE | | | ANY SPACE VAN ACCESSIBLE?. | | | SEC. 504 FBC-EXISTING BUILDING. SEC. 806 FBC-EXISTING | | | BUILDING. SEC. 202.3 FBC-ACCESSIBILITY AND SEC. 103 | | | FBC-ACCESSIBILITY. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER AND FLOOR PLANS WERE | | | PRESENTED TO ROBERT BROWN (BUILDING OFFICIAL) FOR | | | APPROVAL. IT WAS NOT APPROVED. THE LETTER AND THE PLANS | | | SUBMITTED DON'T PROVIDE THE INFORMATION REQUESTED BY | | | ROBERT BROWN WHEN I FIRST SHOW HIM THE PROPOSED | | | ALTERATION FOR BUILDING OFFICIAL INTERPRETATION. I | | | DISCUSSED ROBERT BROWN'S INTERPRETATION WITH VALENTINA | | | LEONI FROM MARMOL RADZINER AIA OVER THE PHONE. I | | | INFORMED HER THAT ROBERT BROWN WOULD APPROVE THE | | | PROPOSED "STORAGE ONLY" PARKING SPACES WITHOUT HAVING A | | | DEDICATED ADA SPACE IF THE PLANS AND A LETTER FROM | | | LUCID MOTORS CLEARLY SHOW HOW THE SPACES WERE | | | CONTROLLED TO AVOID USE BY THE GENERAL PUBLIC OR LUCID | | | MOTORS CLIENTS IF THEY ARE IN THE AREA AND ARE IN NEED | | | OF CHARGING THEIR CARS. INFORMATION SUBMITTED DOESN'T | | | SHOW CONTROL OF THESE SPACES. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-06 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-05 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2020-10-06 13:39:43 | BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 1- PROPOSED PARKING SPACES WITH CAR CHARGES DON'T | | | PROVIDE ANY INFORMATION SHOWING COMPLIANCE WITH THE FBC | | | ACCESSIBILITY CODE. IS THERE ANY PARKING SPACE WITH A | | | CAR CHARGER ASSIGNED FOR HANDICAPPED PEOPLE?. IS THERE | | | ANY SPACE VAN ACCESSIBLE?. | | | SEC. 504 FBC-EXISTING BUILDING. SEC. 806 FBC-EXISTING | | | BUILDING. SEC. 202.3 FBC-ACCESSIBILITY AND SEC. 103 | | | FBC-ACCESSIBILITY. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2021-01-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2021-01-05 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2021-01-05 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-21 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-21 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2020-12-21 09:39:20 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE OF WORK IS NOT $15,000 PLEASE SUBMIT A REASONABLE | | | VALUE OF THE WORK. | | | | | | PERMIT STILL STATES IT IS FOR RESTRIPING OF PARKING | | | GARAGE. | | | | | | ELECTRICAL PERMIT REQUIRED FOR ELECTRICAL WORK. | | | | | | PLEASE SHOW WHERE POWER IS COMING FROM ON THE RISER | | | DIAGRAM, SHOW DISCONNECT AT POINT OF FEEDER ENTERING | | | THE GARAGE FACITILTY. SHOW OTHER BUILDING, FEEDER, | | | DISCONNECT, TRANSFORMER, AND THE PANEL........ SHOW | | | THESE ON A PLAN FOR LAYOUT OF JOB. | | | | | | PLEASE SUBMIT A PANEL SCHEDULE FOR PANEL CS | | | | | | PLEASE SUBMIT SIGNAGE COPY OF SIGNS FOR SERVICE AND | | | FEEDERS IN SAME BUILDING FROM DIFFERENT SOURCES. FOR | | | FIRE DEPT. SHOWING LOCATION OF MAINS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2020-12-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-03 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-01 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2020-12-03 15:27:48 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1) A DISCONNECT SHALL BE INSTALLED AT THE POINT OF | | | ENTRANCE TO THE BUILDING FOR THE FEEDER FROM THE OTHER | | | BUILDING. | | | | | | 2) PLEASE SUPPLY A RISER DIAGRAM SHOWING MAIN TO | | | TRANSFORMER, LOCATION OF PANEL CS, LOCATION OF | | | TRANSFORMER TX-CS PLEASE SHOW BREAKERS SIZE AND SIZE OF | | | WIRES. SIGNS SHALL BE PLACED AT BOTH THE FEEDER | | | DISCONNECT'S ENTRANCE INTO THE GARAGE AND ANOTHER SIGN | | | LOCATED AT THE MAIN SERVICE FOR THE GARAGE INDICATING | | | THAT ANOTHER MEANS OF DISCONNECT IS LOCATED ON THE | | | PREMISES AND WHERE IT IS LOCATED. POWER DISCONNECT HAVE | | | TO READILLY AVAILABLE IN ORDER TO DISCONNECT THE ENTIRE | | | ELECTRICAL SYSTEM TO THE GARAGE. | | | | | | 3) VALUE OF JOB IS TO INCLUDE THE CHARGERS PLUS ALL | | | MATERIALS AND LABOR FOR A COMPLETE JOB. (25000) | | | | | | 4) AIC RATING FOR THE SERVICE TO THIS PROJECT 110.9, | | | 110.10 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-27 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2020-10-27 15:13:29 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLANS FOR THIS JOB ARE VERY HARD TO UNDERSTAND. YOUR | | | PLANS ARE NOT CLEAR AND HARD TO READ. I JUST NOW | | | REALIZED THAT YOU ARE BRINGING ANOTHER FEEDER FROM | | | ANOTHER SERVICE INTO THE GARAGE. PLEASE INDICATE NEC | | | COMPLIANCE. | | | | | | 1) SERVICE FOR CHARGERS WILL NEED TO BE GROUPED WITH | | | THE MAINS FOR THE GARAGE. 230.2, 225.30 | | | | | | 2) PLEASE SUPPLY A RISER DIAGRAM SHOWING MAIN TO | | | TRANSFORMER, LOCATION OF PANEL CS, LOCATION OF | | | TRANSFORMER TX-CS | | | | | | 3) VALUE OF JOB IS TO INCLUDE THE CHARGERS PLUS ALL | | | MATERIALS AND LABOR FOR A COMPLETE JOB. (25000) | | | | | | 4) AIC RATING FOR THE SERVICE TO THIS PROJECT 110.9, | | | 110.10 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-25 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-25 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2020-09-25 18:06:11 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) LOAD CALCULATION HOW DID THE 100A CHARGERS GET A VA | | | RATING OF 24,960VA FOR THE LOAD CALULATIONS? ARTICLE | | | 220 | | | HOW DID CHARGES 6 GET TO A LOAD OF 99840VA? 16,640 | | | EACH? PLEASE EXPLAIN. | | | | | | 2) VALUE OF WORK SHOWN IS LOW FOR THIS INSTALLATION, | | | PLEASE INCLUDE ALL MATERIALS AND LABOR FOR THE VALUE. | | | | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | 3) DISTANCE FROM THE SERVICE TO THE PANEL FOR THE | | | CHARGERS IS WHAT DISTANCE? 215.2 IT #1 | | | | | | 4) SUBMIT CHARGER CUT SHEETS. 110.3 | | | | | | 5) SHOW SERVIE RISER FOR CHARGING STATIONS PANEL, | | | BRANCH, GROUNDING. 215.5 | | | | | | 4) VD CA;CULATION WAS BASED ON 320 AMPERES HOW DID YOU | | | GET TO 320A ?? |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2020-10-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-10-23 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2020-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2020-09-24 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2021-01-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2021-01-06 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-29 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-12-23 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2020-12-23 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2020-12-16 |
Time |
16:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-12-15 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-25 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-29 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-22 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-06 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-09-23 |
Time |
07:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-12-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-12-21 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-12-21 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-12-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-08 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-12-08 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-10-23 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-10-23 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-10-23 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-06 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-06 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-12-23 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2020-12-23 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2020-12-23 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2020-12-23 09:15:51 | 12/23/20- PASSED | | | 1) THE LUCID INVENTORY PARKING/CHARGING IS NOT APPROVED | | | FOR THE PUBLIC (LUCID CAR OWNERS) ACCESS/CHARGING; AND | | | CUSTOMERS ARE NOT PERMITTED TO BE BROUGHT TO THIS AREA | | | BY SALESMEN TO REVIEW CARS THAT ARE NOT IN THE | | | SHOWROOM, BEING ATEST DRIVE, ETC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-12-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-12-15 |
Time |
10:11 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2020-12-08 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2020-12-15 10:34:37 | FAILED | | | | | | 1) THE LUCID INVENTORY PARKING/CHARGING IS NOT APPROVED | | | FOR PUBLIC (LUCID CAR OWNERS) ACCESS/CHARGING; | | | THEREFORE, ZONING WILL NOT APPROVE THE REVISION. | | | ADDITONALLY, CUSTOMERS ARE NOT PERMITTED TO BE BROUGHT | | | TO THIS AREA BY SALESMEN TO REVIEW CARS THAT ARE NOT IN | | | THE SHOWROOM, BEGIN A TEST DRIVE, ETC. | | | | | | 2) THE INSTALLATION OF THE WIDER SPACE AND THE ACCESS | | | AISLE FOR AN ADA SPACE ENCROACHES INTO, AND MAKES THE | | | ADJACENT NON LUCID SPACE A NON-CODE COMPLIANT SIZE, | | | WHICH REMOVES THIS SPACE FROM THE OVERALL PARKING | | | AVAILABILITY. | | | | | | 3) THE CONVERSION OF TWO NORMAL PARKING SPACES TO AN | | | ADA SPACE AND THE ACCESS AISLE ON THE WEST SIDE OF THE | | | DRIVE AISLE RESULTS IN THE REMOVAL OF A PARKING SPACE. | | | | | | 4) EVEN THOUGH COMMENT #1 DOES NOT PERMIT THE USE OF | | | THESE SPACES BY THE PUBLIC OR ACCESS BY CUSTOMERS (THUS | | | NOT REQUIRING ADA) CITY RETAIL HAS NOT AUTHORIZED THE | | | REMOVAL ON ADDITIONAL PARKING SPACES NOR HAS STAFF | | | REVIEWED HOW THIS WOULD AFFECT THE OVERALL PARKING | | | INVENTORY FOR ROSEMARY SQUARE. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-10-29 |
Time |
16:55 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2020-10-29 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2020-10-06 |
Time |
09:56 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2020-10-06 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2020-10-06 10:48:32 | FAILED | | | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | | | 1) PLEASE VERIFY WHAT THE SPECIFIC PROPOSED USE OF | | | THESE SPACES IS. | | | | | | 2) THE WHEEL STOPS, LOCATED THREE FEET FROM THE FRONT | | | OF THE SPACE, DOES NOT CONFORM TO CITY REQUIREMENTS FOR | | | SPACES WHERE CARS ARE LOCATED. THE REMAINING 15 FEET IS | | | NOT AN ADEQUATE DEPTH TO ENSURE THAT THE BACK OF THE | | | CARS EXTEND OUT OF THE SPACE AND BLOCK THE DRIVE AISLE. | | | THE CITY REQUIREMENT IS THAT WHEEL STOPS BE TWO FEET | | | FROM THE END OF THE PARKING SPACE. | | | | | | 3) THE SPACE WITH THE BOLLARD AND PIPE NEEDS TO BE | | | DESIGNATED AND USED ONLY FOR COMPACT LUCID CARS (SPACE | | | 16 FEET IN DEPTH) OR IT MAY NOT BE USED AS A FULL SIZED | | | VEHICLE IN THIS SPACE WOULD ENCROACH INTO THE REQUIRED | | | DRIVE AISLE. | | | | | | 4) THE CITY REQUIRES THE DIVIDER LINES TO BE WHITE. THE | | | PROPOSED LIQUORICE COLOR IS NOT PERMITTED. | | | | | | 5) THE HANGING SIGNAGE REQUIRES PERMITS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] | | | | | | | | | | | | |
|
|