| Plan Review Stops For Permit 20090566 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-20 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-19 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2020-10-27 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-27 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2020-10-27 14:12:52 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PRODUCT APPROVALS LISTED ON THE DRAWINGS AND PRODUCT | | | APPROVALS PROVIDED ARE NOT CORRECT - PORDUCT APPROVAL | | | (17-1212.12) AND (20-0428.01) ARE FOR FIXED GLASS | | | WINDOWS THEY NEED TO BE FOR SINGLE HUNG WINDOWS. | | | 2) A ROOFING SHINGLE PRODUCT APPROVAL HAS NOT BEEN | | | PROVIDED - IF YOU WOULD LIKE THE ROOFING SYSTEM TO BE | | | DEFERRED PLEASE PROVIDE A STATEMENT REQUESTING THE | | | ROOFING SYSTEM PERMIT BE DEFERRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-01 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-01 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2020-10-01 10:50:44 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR DOORS AND | | | WINDOWS. (COMPLETE = FRONT PAGES AND THE INSTALLATION | | | INSTRUCTIONS). ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD OR BE MENTIONED ON THE DRAWING. | | | 2) R30 BATT INSULATION SHOWN IN THE 2X6 RAFTERS WILL | | | NOT GIVE YOU THE REQUIRED 1 INCH VENTILATION REQUIRED | | | FBC R806.3 VENT AND INSULATION CLEARANCE. | | | WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION | | | SHALL NOT BLOCK THE FREE FLOW OF AIR. NOT LESS THAN A | | | 1-INCH (25 MM) SPACE SHALL BE PROVIDED BETWEEN THE | | | INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION | | | OF THE VENT. | | | 3) PLEASE PROVIDE A COMPLETE MIAMI DADE OR FLORIDA | | | STATE PRODUCT APPROVAL FOR THE ROOFING SHINGLES. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-11-30 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-30 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-30 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-29 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-10-29 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-10-29 |
Time |
19:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-09-30 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2020-09-30 |
Time |
21:18 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2020-09-30 |
Time |
20:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-11-19 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-11-19 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-11-17 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-11-17 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-09-25 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-09-25 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2020-09-25 15:55:29 | PROPERTY LOCATED IN HISTORIC DISTRICT. SCOPE OF WORK | | | REQUIRES SUBMITTAL OF CERTIFICATE OF APPROPRIATENESS | | | (COA) FOR REVIEW OF ARCHITECTURAL CHANGES. | | | | | | QUESTIONS, CONTACT: | | | FRIEDERIKE MITTNER, CITY HISITORIC PRESERVATION PLANNER | | | (561) 822-1457 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-30 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-30 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-18 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-17 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-10-22 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-01 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-22 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-23 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-23 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-19 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-19 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2020-11-19 11:24:53 | 11/19/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-26 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-26 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2020-10-26 16:27:17 | 10/26/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-23 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-23 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2020-09-23 18:23:16 | 09/23/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE SHOW THE ISOMETRIC DRAWING BY ITSELF AS THE | | | WAY IT IS DRAWN TO MANY LINES. WE CANNOT DETERMINE WHAT | | | GOES WERE PER THE WEST PALM BEACH AMENDMENTS TO FBC | | | SEC. 107.2.1. | | | | | | 2. ON THE ISOMETRIC, THE SANITARY LINE THAT GOES TO | | | PICK UP THE KITCHEN AND WASHING MACHINE SHOULD BE | | | DOWNSTREAM FROM THE WET VENT OF THE BATHROOM GROUPS PER | | | THE 2017 FBC SEC. R 3108.1. | | | | | | 3. THE WASHING MACHINE IS ON A TWO INCHES SANITARY LINE | | | AND PER MOST MANUFACTURER'S SPECIFICATIONS IT REQUIRES | | | A THREE-INCH DRAIN LINE UP TO THE SANITARY TEE PLEASE | | | CHANGE PER THE PER THE WEST PALM BEACH AMENDMENTS TO | | | FBC SEC. 107.2.1. | | | | | | 4. THE AIR CONDITION DRAIN LINE CANNOT DUMP INTO THE | | | SANITARY LINE IT MUST BE DRAINED OUTSIDE THE STRUCTURE | | | A FOOT AWAY FROM THE STRUCTURE PER THE 2017 FBC SEC. | | | R318.5. | | | | | | 5. THE WASHING MACHINE VALVES SHALL BE ACCESSIBLE | | | WITHOUT MOVING OF THE UNITS AND WITHIN REACH PER THE | | | 2017 FBC SEC. R 2903.9.3. | | | | | | 6. SUBMIT A SLAB REPAIR DETAIL AND SHOW THE WIDTH OF | | | THE REPAIR, THE MINIMUM THICKNESS OF THE CONCRETE TO BE | | | REPLACED, AND THE PSI OF THE CONCRETE. SHOW THE SIZE | | | AND LENGTH OF THE DOWELS, THE MINIMUM EMBEDMENT DEPTH | | | INTO THE EXISTING SLAB, THE ANCHORING MATERIAL FOR THE | | | DOWELS, AND THE SPACING OF THE DOWELS ON CENTER. THE | | | REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL | | | AND THE REQUIRED VAPOR BARRIER OVER WELL-COMPACTED | | | SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE | | | FOR A FINAL INSPECTION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-20 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-20 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
mcphers |
Date |
2020-10-27 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-27 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2020-10-27 14:18:27 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-10-01 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-01 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-01 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2020-10-01 11:00:46 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-20 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-20 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-27 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-27 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-23 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-23 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-11-19 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-11-19 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2020-09-25 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2020-09-25 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|