Plan Review Details - Permit 20090515
| Plan Review Stops For Permit 20090515 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-10 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-10 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-24 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-24 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2020-11-24 10:34:42 | CODES IN EFFECT | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | REVIEW STATUS: FAILED. | | | | | | 1) SPECIFY FULL LOAD CURRENT, CONDUCTOR SIZE, EQUIPMENT | | | GROUNDING CONDUCTOR, BREAKER SIZE FOR CIRCUITS FEEDING | | | THE 5 HP PUMPS. NEC 430 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | ENRIQUE QUINONEZ | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-12-10 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-12-01 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
equinone |
Date |
2020-11-24 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
equinone |
Date |
2020-11-13 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-16 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2020-11-16 13:14:48 | 11/16/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-16 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |