| Plan Review Stops For Permit 20090380 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-11-10 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-10 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2020-11-10 18:30:14 | 11/10/2020 TALKED TO MARCELA PEDRAZA. ISSUE PERMIT WITH | | | PROVISO. JG. | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | REVISE ENERGY CALCULATIONS; | | | A) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM. THE ZIP CODE FOR THIS ADDRESS IS 33405 NOT 33409. | | | NEED OWNER'S NAME, BUILDER'S NAME. SEC. | | | B)THIS IS NOT AN ADDITION. THIS IS EXISTING | | | CONSTRUCTION. REVISE ITEM #1 ON PAGE 1 OF 4. SEE PLANS | | | AND REVISE. | | | C) SQUARE FEET OF CONDITIONED FLOOR AREA SHOWN ON ITEM | | | #6 ON PAGE 1 OF 4 DOESN'T MATCH PLANS AND PROPERTY | | | APPRAISER. WHERE IS THE 1721 S.F. TAKEN FROM?. SEE | | | PLANS AND REVISE AS REQUIRED. PROVIDE SKETCH SHOWING | | | THE SPECIFIED SQUARE FOOTAGE. | | | D)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 IS INCORRECT. | | | THIS HOUSE HAS CONCRETE TILE NOT SHINGLES. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-11-05 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-05 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2020-11-05 16:23:43 | RESIDENTIAL (R3) SECOND BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO | | | ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR | | | IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | | ISSUANCE. | | | | | | | | | ***IMPORTANT*** | | | ENERGY CALCULATIONS NEED TO BE CERTIFIED BY THE OWNER | | | OR AUTHORIZED AGENT BEFORE ISSUING THE PERMIT. | | | | | | | | | ORIGINAL COMMENT: | | | 1- BASED ON THE SCOPE OF WORK SHOWN ON PLANS. THIS IS | | | AN ALTERATION LEVEL 3 AND PARTIAL CHANGE OF USE | | | (CHANGING USE OF EXISTING GARAGE). SEC. 505 AND SECTION | | | 506 FBC-EXISTING BUILDING. | | | NEED TO PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 908 FBC-EXISTING BUILDING AND SEC. R101.5.1 FBC-ENERGY | | | CONSERVATION. PLEASE HAVE FORM PROPERLY SIGNED BY THE | | | OWNER OR AUTHORIZED AGENT TO HELP EXPEDITE THE REVIEW | | | PROCESS. | | | NOTE: THIS BUILDING IS CONSIDERED A "RENOVATED | | | BUILDING". THEREFORE, IT IS NOT EXEMPT FROM THE ENERGY | | | CODE. SEE SEC. R101.4.2 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE TO ENERGY CALCULATIONS SUBMITTED: | | | A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED | | | AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S | | | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY | | | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY | | | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 6TH EDITION | | | (2017). | | | | | | B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM. THE ZIP CODE FOR THIS ADDRESS IS 33405 NOT 33409. | | | NEED OWNER'S NAME, BUILDER'S NAME. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION. | | | | | | C)THIS IS NOT AN ADDITION. THIS IS EXISTING | | | CONSTRUCTION. REVISE ITEM #1 ON PAGE 1 OF 4. SEE PLANS | | | AND REVISE. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | D)SQUARE FEET OF CONDITIONED FLOOR AREA SHOWN ON ITEM | | | #6 ON PAGE 1 OF 4 DOESN'T MATCH PLANS AND PROPERTY | | | APPRAISER. WHERE IS THE 1721 S.F. TAKEN FROM?. SEE | | | PLANS AND REVISE AS REQUIRED. PROVIDE SKETCH SHOWING | | | THE SPECIFIED SQUARE FOOTAGE. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | E)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 IS INCORRECT. | | | THIS HOUSE HAS CONCRETE TILE NOT SHINGLES. REVISE AS | | | REQUIRED. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-02 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-01 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2020-10-02 17:28:02 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE. | | | | | | 1- BASED ON THE SCOPE OF WORK SHOWN ON PLANS. THIS IS | | | AN ALTERATION LEVEL 3 AND PARTIAL CHANGE OF USE | | | (CHANGING USE OF EXISTING GARAGE). SEC. 505 AND SECTION | | | 506 FBC-EXISTING BUILDING. | | | NEED TO PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | 908 FBC-EXISTING BUILDING AND SEC. R101.5.1 FBC-ENERGY | | | CONSERVATION. PLEASE HAVE FORM PROPERLY SIGNED BY THE | | | OWNER OR AUTHORIZED AGENT TO HELP EXPEDITE THE REVIEW | | | PROCESS. | | | NOTE: THIS BUILDING IS CONSIDERED A "RENOVATED | | | BUILDING". THEREFORE, IT IS NOT EXEMPT FROM THE ENERGY | | | CODE. SEE SEC. R101.4.2 FBC-ENERGY CONSERVATION. | | | | | | 2- SHEET 1.0A: | | | A)DESIGN PROFESSIONAL SPECIFIES CONSTRUCTION TYPE IIIB | | | AT THE BOTTOM RIGHT OF THIS DRAWING. ACCORDING TO TABLE | | | 601 FBC-BUILDING CONSTRUCTION TYPE IIIB REQUIRES | | | EXTERIOR BEARING WALLS TO BE 2 HOUR FIRE RATED. PROVIDE | | | PROOF THAT EXISTING EXTERIOR BEARING WALLS ARE 2 HOUR | | | FIRE RATED OR REVISE CONSTRUCTION TYPE TO MATCH ACTUAL | | | CONSTRUCTION. (NOTE: TYPICALLY, ONE AND TWO FAMILY | | | RESIDENCES ARE CONSTRUCTION TYPE VB). | | | | | | B)DESIGN PROFESSIONAL SPECIFIES OCCUPANCY TYPE "R". | | | THERE ARE MANY TYPES OF "R" OCCUPANCIES. CLEARLY | | | SPECIFY WHICH "R" OCCUPANCY IS THIS BUILDING. | | | SEC. 310 FBC-BUILDING. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-09-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-09-30 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-09-30 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-11-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-12 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-12 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2020-11-12 14:30:39 | 11/12/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-22 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-22 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2020-09-22 18:29:08 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER | | | THE WPB AMENDMENTS TO FBC SEC. 107.2.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-11-12 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-12 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-30 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2020-10-20 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2020-09-21 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2020-10-02 18:09:02 | 10/02/2020 ADDED ZONING REVIEW STOP. VALUE OF | | | RENOVATION IS MORE THAN 50% OF VALUE OF STRUCTURE | | | ACCORDING TO PAPA. ALSO, CHANGING THE USE OF GARAGE. | | | JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2020-12-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-12-02 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-20 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2020-12-02 11:07:51 | NO FEES DUE. SEE COUNTY STAMP ON SHEET 1.0A OF 7. | | | JG. | | 2020-11-20 14:48:47 | EMAIL PBC TO REVIEW IMPACT FEES. IMPACT FEES | | | QUESTIONNAIRE HAS BEEN UPLOADED IN PROJECTDOX. CC |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2020-10-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-02 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-02 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2020-10-02 17:06:27 | IMPACT FEES - DIGITAL SUBMITTALS. | | | | | | CHANGING USE OF EXISTING GARAGE. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-06 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-22 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-22 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-06 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-06 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2020-11-06 10:18:32 | PLEASE SEE BUILDING REVIEWERS COMMENTS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-09-22 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-09-22 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2020-09-22 18:28:23 | 09/22/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-11-10 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-10 |
Time |
18:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-11-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-11-06 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-11-06 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2020-11-06 10:21:46 | PLEASE SEE BUILDING REVIEWERS COMMENT ABOUT SIGNING THE | | | ENERGY COMPLIANCE REPORT. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-22 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-22 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2020-10-20 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2020-10-20 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|