Plan Review Details - Permit 20090300
| Plan Review Stops For Permit 20090300 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-24 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-24 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-14 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-14 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2020-09-14 11:44:55 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING APPROVED WITH PROVISO: | | | | | | 1) AWS D1.1 CLAUSE 4.9.3.5: AT TIME OF INSPECTION, | | | PROVIDE ENGINEER'S SIGNED/SEALED LETTER FOR | | | CLARIFICATION OF INTERRUPTED WELDS AT OPPOSITE SIDES OF | | | A COMMON PLANE FOR COLUMN TO BEAM CONNECTIONS. | | | | | | 2) AWS D1.1 CLAUSE 5.2 & 6.7: AT TIME OF INSPECTION | | | PLEASE PROVIDE A WELD PROCEDURE SPECIFICATION; THE | | | W.P.S. SPECIFIES THE REQUIRED ESSENTIAL VARIABLES | | | INCLUDING: BASE MATERIALS, JOINTS, PROCESS, AND FILLER | | | METALS TO BE USED. | | | AWS D1.1 CLAUSE 6.16: AT TIME OF INSPECTION PLEASE | | | PROVIDE A WELDER PERFORMANCE QUALIFICATION RECORD; THE | | | W.P.Q.R. PROVIDES INFORMATION WHICH CAN BE USED TO | | | VERIFY THE WELDER?S QUALIFICATION AND CERTIFICATION AS | | | IT RELATES TO THE WELDING REQUIREMENTS OF THE PROJECT. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-24 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-23 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-14 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-05 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2020-09-08 15:06:18 | SENT TO MISCELLANEOUS #1. JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-09-24 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-09-24 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2020-09-24 16:04:56 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED BY SIGNED/SEALED PAPER PLANS. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |