| Plan Review Stops For Permit 20090244 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-28 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2020-10-28 13:35:05 | 10/28/2020 TALKED TO STEVE SLAGLE. INSTALLING W-2 | | | ASSEMBLY. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-26 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-26 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2020-10-26 10:43:37 | RESIDENTIAL (R3) REROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK | | | SHALL COMPLY WITH THE MATERIALS AND METHODS | | | REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL30268-R1 | | | SUBMITTED: | | | SELECTED ASSEMBLY W-1 CAN NOT BE USED. THIS ASSEMBLY | | | DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES AS | | | REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. BONDED | | | ASSEMBLIES NEED TO MEET THE DESIGN PRESSURES FOR ALL | | | ROOF ZONES. SEE NOTE #10 ON PAGE 2 OF 45 OF PRODUCT | | | APPROVAL SUBMITTED. | | | NEED TO SELECT ANOTHER BONDED ASSEMBLY THAT MEETS THE | | | DESIGN PRESSURES FOR ALL ROOF ZONES REQUIRED BY SEC. | | | R301.2.1 FBC-RESIDENTIAL. OR SELECT ANOTHER | | | MECHANICALLY FASTENED ASSEMBLY THAT MEETS THE DESIGN | | | FOR ALL ROOF ZONES. OR SELECT ANOTHER ASSEMBLY THAT | | | ALLOWS NAIL ENHANCEMENT BY DOING RAS 117 CALCULATIONS. | | | IF RAS 117 CALCULATIONS ARE PROVIDED, THEN THEY NEED TO | | | BE PROPERLY SIGNED AND SEALED BY THE DESIGN | | | PROFESSIONAL. | | | | | | 2- REPEAT COMMENT FROM PREVIOUS PLAN REVIEWERS. NO | | | CLEAR WHY SUBMITTING PRODUCT APPROVALS FOR SHINGLES. | | | ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER THERE | | | ARE ONLY FLAT ROOFS ON THE TWO STRUCTURE ON THIS | | | PROPERTY. REVISE/CLARIFY AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-10-22 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-10-22 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2020-10-22 08:13:58 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. PLEASE ADDRESS THE PREVIOUS PLAN REVIEWERS COMMENTS | | | DATED 10/19/2020 AND 9/10/2020 AND RESUBMIT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-10-19 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-10-19 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2020-10-19 10:04:15 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, THE SUBMITTED INFORMATION NEEDS TO BE | | | CLARIFIED: | | | | | | IF THIS PERMIT APPLICATION IS INTENDED FOR SHINGLES, | | | SHOW THE LOCATION OF SHINGLES, AS PHOTOS ON RECORD ONLY | | | SHOW FLAT ROOFS, NO SLOPED ROOF. | | | IF THIS PERMIT APPLICATION IS FOR THE FLAT ROOF, | | | INDICATE BY MARKING ON THE PRODUCT APPROVAL/NEMO REPORT | | | WHICH SYSTEM AND/OR SYSTEMS WILL BE USED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-09-10 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-09-10 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2020-09-10 12:09:19 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. PAPA IMAGE SHOWS FLAT ROOF SYSTEM. | | | SHINGLES ALLOWED ON ROOFS HAVING A SLOPE (2:12) OR | | | GREATER. PLEASE PROVIDE APPROVED PRODUCT | | | APPROVALS/NOA?S FOR A FLAT ROOF SYSTEM. | | | 2. FBC R 301 FAC9N-3 FOR FLORIDA STATE PRODUCT APPROVAL | | | FL28697 IS INCOMPLETE, PROVIDE THE FOLLOWING ADDITIONAL | | | INFORMATION: COVER SHEET (WWW.FLORIDABUILDING.ORG, THIS | | | WILL INCLUDE THE CODE VERSION, PRODUCT APPROVAL NUMBER, | | | STATUS, GENERAL INFORMATION ABOUT THE PRODUCT) | | | EVALUATION REPORT. PROVIDE TWO COMPLETE SETS FOR THE | | | PROPOSED ROOFING UNDERLAYMENT USED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2020-10-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-28 |
Time |
13:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-10-26 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-10-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-10-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-10-22 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-10-20 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-10-19 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-10-16 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-09-10 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-09-08 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2020-09-10 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2020-09-10 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|