Plan Review Details - Permit 20090085
Plan Review Stops For Permit 20090085
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By jwitmer Date 2020-11-12 Time 15:06 Rev Time 0.00
Received By jwitmer Date 2020-11-12 Time 14:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-24 Cont ID  
Sent By jwitmer Date 2020-09-24 Time 09:32 Rev Time 0.00
Received By jwitmer Date 2020-09-24 Time 08:47 Sent To  
Notes
2020-09-24 08:52:15WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20090085 7/11 FUEL CANOPY
 ADD: 301 SOUTHERN BLVD.
 CONT: TBD/ TO BE ANNOUNCED
 TEL: ???
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. SEPT. 24TH / 2020
 ACTION: DENIED
  
 1) NO SITE PLAN SUBMITTED WITH THIS PERMIT. THE
 CONVENIENCE STORE PERMIT 20090083 DOES HAVE A SITE
 PLAN. THE CONCERN IS THE CLOSENESS OF THE EXCAVATION OF
 THE FUEL TANKS AND DEPTH OF THE EXCAVATION OF THE FUEL
 TANKS TO THE FOUNDATION FOR THE FUELING CANOPY.
 2017 FBC-B 1804.1. EXCAVATION NEAR FOUNDATIONS.
 EXCAVATION FOR ANY PURPOSE SHALL NOT REDUCE THE LATERAL
 SUPPORT FROM ANY FOUNDATION OR ADJACENT FOUNDATION
 WITHOUT FIRST UNDERPINNING OR PROTECTING THE FOUNDATION
 AGAINST DETRIMENTAL LATERAL OR VERTICAL MOVEMENT, OR
 BOTH.
  
 2) NOTES ON SHEET CS1-CANOPY STATE SPECIAL INSPECTIONS
 FOR CANOPY FOR BOLTED AND WELDED CONNECTIONS.
 WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 REPORTS SUBMITTED TO BUILDING INSPECTOR AT TIME OF
 FRAMING INSPECTION.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT
 561-805-6666.
  
 3) NOTES ON SHEET CS-1 CANOPY, NOTE # 4 SOILS REPORT
 FROM ARDAMAN & ASSOCIATES REPORT # 20-1691. SITE SOILS
 SHALL BE PREPARED FOR THE FOUNDATION IN ACCORDANCE WITH
 GEOTECHNICAL REPORT REFERENCES ABOVE. BO SOILS REPORT
 WAS SUBMITTED.
 QUESTIONABLE SOILS. 1803.5.2 QUESTIONABLE SOIL. WHERE
 THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE
 SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR
 TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING
 OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A
 GEOTECHNICAL INVESTIGATION BE CONDUCTED.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-11-20 Cont ID  
Sent By jleahy Date 2020-11-20 Time 15:26 Rev Time 0.00
Received By jleahy Date 2020-11-20 Time 15:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-09-18 Cont ID  
Sent By jleahy Date 2020-09-18 Time 09:31 Rev Time 0.00
Received By jleahy Date 2020-09-18 Time 09:11 Sent To  
Notes
2020-09-18 09:32:15ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY BN, BU, PX
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO ELECTRIC SHOWN.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2020-11-16 Cont ID  
Sent By pleduc Date 2020-11-16 Time   Rev Time 0.00
Received By pleduc Date 2020-11-16 Time 15:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-09-14 Cont ID  
Sent By pleduc Date 2020-09-14 Time   Rev Time 0.00
Received By pleduc Date 2020-09-11 Time 11:18 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2020-11-24 Cont ID  
Sent By fmittner Date 2020-11-24 Time 11:56 Rev Time 0.00
Received By fmittner Date 2020-11-24 Time 11:56 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2020-09-25 Cont ID  
Sent By fmittner Date 2020-09-25 Time 09:56 Rev Time 0.00
Received By fmittner Date 2020-09-25 Time 09:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-12-10 Cont ID  
Sent By ccarvaja Date 2020-12-10 Time 13:19 Rev Time 0.00
Received By ccarvaja Date 2020-11-10 Time 13:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-25 Cont ID  
Sent By shill Date 2020-09-25 Time 11:10 Rev Time 0.00
Received By shill Date 2020-09-10 Time 13:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-11-12 Cont ID  
Sent By jwitmer Date 2020-11-12 Time 15:06 Rev Time 0.00
Received By jwitmer Date 2020-11-12 Time 14:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2020-09-24 Cont ID  
Sent By jwitmer Date 2020-09-24 Time 09:34 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2020-11-24 Cont ID  
Sent By fmittner Date 2020-11-24 Time 11:56 Rev Time 0.00
Received By fmittner Date 2020-11-24 Time 11:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-25 Cont ID  
Sent By fmittner Date 2020-09-25 Time 09:56 Rev Time 0.00
Received By fmittner Date 2020-09-25 Time 09:56 Sent To  
Notes
2020-09-25 09:56:29REFER TO MASTER PERMIT FOR EXAT LOCATION


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved