| Plan Review Stops For Permit 20081412 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-16 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-16 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-20 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-20 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2020-10-20 16:36:36 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE FIRST PAGE OF THE POOL PLANS IS NUMBERED 1 OF 4. | | | THERE WERE ONLY 3 PAGES OF PLANS. THE OTHERS ARE | | | NUMBERED 2 OF 3 AND 3 OF 3. PLEASE CORRECT. FBC 107.2.1 | | | | | | 2) THE FIRST PAGE OF THE PLANS IS NOT SIGNED AND SEALED | | | BY THE ENGINEER. FS 471 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-12-09 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-12-09 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-10-05 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-10-05 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2020-10-05 13:13:14 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | 2.INCLUDE NEW GUEST HOUSE IN CALCULATION IF ON SAME | | | SERVICE. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-16 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-12-08 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-03 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-02 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-12-09 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-12-09 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2020-12-09 09:51:36 | 12/09/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2020-10-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-05 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-05 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2020-10-05 10:13:26 | 10/05/20 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. PLEASE PROVIDE PUMP CURVE AND SHOW ON THE POOL PUMP | | | CURVE WHICH CURVE KEY IS SPECIFIC TO THE PUMP BEING | | | INSTALLED ON THIS POOL. THIS IS NEEDED TO CONFIRM THE | | | MAXIMUM SYSTEM FLOW FROM THE TDH CALCULATIONS PER THE | | | ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, 4.4.9.1. | | | | | | 2. PLEASE SUBMIT SPECIFICATIONS FOR THE PUMP AND | | | CARTRIDGE FILTER PER THE WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | 3. THIS IS A MULTI-FAMILY DWELLING, IF THERE ARE NOT | | | TWO METERS FOR WATER USERS IT WILL REQUIRE TO INSTALL A | | | BACKFLOW PREVENTION ASSEMBLY AT THE POINT OF DELIVERY. | | | THE TYPE OF BACKFLOW ASSEMBLY REQUIRED WILL BE | | | DEPENDENT UPON THE DEGREE OF HAZARD POSED BY THE WATER | | | USER. IF ONE METER THIS PROPERTY WILL REQUIRE A REDUCED | | | PRESSURE ZONE ASSEMBLY VACUUM BREAKER. A PERMIT IS | | | REQUIRED BY A LICENSED CONTRACTOR AND MUST BE CERTIFIED | | | BY UTILITIES BEFORE FINAL INSPECTION. PLEASE CONTACT | | | THE CITY OF WPB UTILITIES AT 561-822-2240 FOR FURTHER | | | DIRECTIONS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2020-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-12-16 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-10-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-20 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-20 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2020-10-20 16:28:29 | SHEET 1 OF THE POOL PLANS IS NOT SIGNED AND SEALED. | | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | | ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS | | | REQUIRED TO BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER | | | FACSIMILES OF THE SIGNATURE ARE ACCEPTABLE. FS 471 & | | | 61G15 |
|
|