| Plan Review Stops For Permit 20081298 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-20 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-20 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-08 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-08 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-23 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-23 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2020-09-23 12:43:02 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PRE-FAB GENERATOR PAD DRAWING THAT WERE | | | SUBMITTED IS THE CORRECT ONE. HOWEVER, IT IS A COPY AND | | | AN ORIGINAL IS REQUIRED WHEN SUBMITTING FOR PUBLIC | | | RECORD. FS 471 & FAC 61G-15 SEE SIGNATURE COMMENTS. | | 2020-09-05 06:43:02 | VALUE APPEARS LOW. ESTIMATE IS FOR AN UNDERGROUND FUEL | | | TANK AND RELATED WORK. PROVIDE VALUE OF ALL LABOR AND | | | MATERIALS FOR THE GENERATOR / STRUCTURAL PAD AND | | | ELECTRICAL EQUIPMENT. CT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-06 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-06 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2020-09-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-05 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-05 |
Time |
06:38 |
Sent To |
|
|
| Notes |
| 2020-09-05 07:03:03 | PLAN REVIEW / GENERATOR / ELECTRICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NEC 2014 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ESTIMATE IS FOR AN UNDERGROUND FUEL TANK AND RELATED | | | WORK. PROVIDE VALUE OF ALL LABOR AND MATERIALS FOR THE | | | GENERATOR / STRUCTURAL PAD AND ELECTRICAL EQUIPMENT. | | | | | | 1. CITY OF WPB CHPT. 1 VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. | | | | | | 1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. | | | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, | | | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE | | | OF WORK. | | | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY | | | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | BASED ON THE INFORMATION PROVIDED, VALUE CANNOT BE | | | DETERMINED AT THIS TIME. | | | PLEASE INCREASE THE VALUATION ACCORDINGLY. | | | | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-11-17 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-11-17 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2020-11-17 15:30:17 | LP GAS TANK AND GAS PIPING APPROVED UNDER PERMIT- | | | 20090131. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-28 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-28 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2020-09-28 15:06:01 | 2ND REVIEW FBC-2017 RES. FUEL GAS | | | PERMIT- 20081298 | | | 9/28/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | COMMENTS FROM THE 1ST REVIEW LISTED BELOW STILL EXIST. | | | NO NEW PLANS, SPECIFICATIONS ETC. OR COMMENT RESPONSES | | | WERE PROVIDED- PLEASE COMPLY. | | | | | | 1) PROVIDE AN LP GAS RISER DRAWING SHOWING THE TYPES | | | AND SIZES OF PIPING; TOTAL DEVELOPED LENGTH OF THE | | | SYSTEM AND LENGTHS OF BRANCHES TO ALL NEW AND EXISTING | | | LP APPLIANCES OR EQUIPMENT; TOTAL BTUH LOAD OF THE | | | SYSTEM AND INDIVIDUAL LOADS OF APPLIANCES OR EQUIPMENT; | | | LOCATIONS AND TYPES OF SHUTOFF VALVES, LOCATIONS AND | | | MAKES AND MODELS OF REGULATORS INCLUDING INLET AND | | | OUTLET PRESSURES, LOCATIONS OF UNION, RISERS AND FLEX | | | CONNECTORS; AND A LIST OF GAS PIPE SIZING TABLES- | | | SECTION 107.2.1 WPB. PLEASE NOTE THE UPDATED GENERAC | | | SPECIFICATIONS INDICATE THE A 306,000 FULL BTUH LOAD | | | FOR THE 22 KW GENERATOR. PROVIDE UPDATED SPECS AND | | | MARKED UP SPECS FOR THE REGULATORS SHOWING THE SELECTED | | | MODELS TO BE INSTALLED. | | | | | | 2) SUBMIT A SUB-PERMIT FOR THE INSTALLATION OF THE TANK | | | AND THE PIPING- SECTION 105.1 WPB. THE SUBMITTED | | | APPLICATIONS BEAR EC LICENCES WHICH ARE NOT VALID FOR | | | THE LP TANK INSTALLATION. THE SUB-PERMIT APPLICATION | | | SHALL BEAR THE CONTRACTOR'S FDACS LP GAS LICENSE | | | NUMBER. | | | | | | 3) PLEASE MARK UP THE SUBMITTED SURVEY TO SHOW THE | | | REQUIRED 10 FT. CLEARANCES DISTANCES FROM THE TANK TO | | | THE BUILDING, AND ADJACENT PROPERTY LINES- TABLE | | | 6.3.1.1 NFPA 58. PLEASE SHOW THE PIPING RUN ON THE | | | SURVEY FROM THE TANK TO THE GENERATOR. | | | | | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | 500-GALLON UG LP TANK SHOWING THE TANK AND DOME HAVE | | | BEEN DESIGNED, FABRICATED, TESTED AND MARKED (STAMPED) | | | IN ACCORDANCE WITH THE REGULATIONS AS REQUIRED BY THE | | | REGULATORY AGENCIES AND COMPLIANCE STANDARDS LISTED IN | | | SECTION 5.2.1.1 NFPA 58. | | | | | | 5) PROVIDE LP TANK INSTALLATION DETAILS AS OUTLINED IN | | | THE SUBMITTED CONTRACT, AND AS REQUIRED BY NFPA 58: | | | A) ENGINEERING FOR ANCHORING THE TANK TO PREVENT | | | FLOTATION, COLLAPSE, OR LATERAL MOVEMENT- SECTION | | | 6.6.1.6. PLEASE INCLUDE A FRONT AND SIDE ELEVATION VIEW | | | THAT SHOWS THE BURIAL DEPTH, ANCHORING BASE MATERIAL, | | | AND THE TYPES, SIZES, AND NUMBERS OF ANCHORS, CABLES OR | | | STRAPS, AND THE TYPE OF PROTECTIVE SLEEVES FOR THE | | | CABLES OR STRAPS | | | B) SHOW HOW THE TANK WILL BE PROTECTED AGAINST | | | CORROSION BY INSTALLATION OF A CATHODIC PROTECTION | | | SYSTEM CONSISTING OF A SACRIFICIAL ANODE OR AN | | | IMPRESSED CURRENT ANODE PER SECTIONS 5.2.1.11 & | | | 6.6.6.1(I) NFPA 58. INDICATE THE TYPE OF PROTECTION AND | | | HOW IT WILL BE TESTED- SECTION 6.17.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-24 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-24 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2020-09-24 08:16:52 | 1ST REVIEW FBC-2017 RES. FUEL GAS | | | PERMIT- 20081298 | | | 9/24/2020 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE AN LP GAS RISER DRAWING SHOWING THE TYPES | | | AND SIZES OF PIPING; TOTAL DEVELOPED LENGTH OF THE | | | SYSTEM AND LENGTHS OF BRANCHES TO ALL NEW AND EXISTING | | | LP APPLIANCES OR EQUIPMENT; TOTAL BTUH LOAD OF THE | | | SYSTEM AND INDIVIDUAL LOADS OF APPLIANCES OR EQUIPMENT; | | | LOCATIONS AND TYPES OF SHUTOFF VALVES, LOCATIONS AND | | | MAKES AND MODELS OF REGULATORS INCLUDING INLET AND | | | OUTLET PRESSURES, LOCATIONS OF UNION, RISERS AND FLEX | | | CONNECTORS; AND A LIST OF GAS PIPE SIZING TABLES- | | | SECTION 107.2.1 WPB. PLEASE NOTE THE UPDATED GENERAC | | | SPECIFICATIONS INDICATE THE A 306,000 FULL BTUH LOAD | | | FOR THE 22 KW GENERATOR. PROVIDE UPDATED SPECS AND | | | MARKED UP SPECS FOR THE REGULATORS SHOWING THE SELECTED | | | MODELS TO BE INSTALLED. | | | | | | 2) SUBMIT A SUB-PERMIT FOR THE INSTALLATION OF THE TANK | | | AND THE PIPING- SECTION 105.1 WPB. THE SUBMITTED | | | APPLICATIONS BEAR EC LICENCES WHICH ARE NOT VALID FOR | | | THE LP TANK INSTALLATION. THE SUB-PERMIT APPLICATION | | | SHALL BEAR THE CONTRACTOR'S FDACS LP GAS LICENSE | | | NUMBER. | | | | | | 3) PLEASE MARK UP THE SUBMITTED SURVEY TO SHOW THE | | | REQUIRED 10 FT. CLEARANCES DISTANCES FROM THE TANK TO | | | THE BUILDING, AND ADJACENT PROPERTY LINES- TABLE | | | 6.3.1.1 NFPA 58. PLEASE SHOW THE PIPING RUN ON THE | | | SURVEY FROM THE TANK TO THE GENERATOR. | | | | | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | 500-GALLON UG LP TANK SHOWING THE TANK AND DOME HAVE | | | BEEN DESIGNED, FABRICATED, TESTED AND MARKED (STAMPED) | | | IN ACCORDANCE WITH THE REGULATIONS AS REQUIRED BY THE | | | REGULATORY AGENCIES AND COMPLIANCE STANDARDS LISTED IN | | | SECTION 5.2.1.1 NFPA 58. | | | | | | 5) PROVIDE LP TANK INSTALLATION DETAILS AS OUTLINED IN | | | THE SUBMITTED CONTRACT, AND AS REQUIRED BY NFPA 58: | | | A) ENGINEERING FOR ANCHORING THE TANK TO PREVENT | | | FLOTATION, COLLAPSE, OR LATERAL MOVEMENT- SECTION | | | 6.6.1.6. PLEASE INCLUDE A FRONT AND SIDE ELEVATION VIEW | | | THAT SHOWS THE BURIAL DEPTH, ANCHORING BASE MATERIAL, | | | AND THE TYPES, SIZES, AND NUMBERS OF ANCHORS, CABLES OR | | | STRAPS, AND THE TYPE OF PROTECTIVE SLEEVES FOR THE | | | CABLES OR STRAPS | | | B) SHOW HOW THE TANK WILL BE PROTECTED AGAINST | | | CORROSION BY INSTALLATION OF A CATHODIC PROTECTION | | | SYSTEM CONSISTING OF A SACRIFICIAL ANODE OR AN | | | IMPRESSED CURRENT ANODE PER SECTIONS 5.2.1.11 & | | | 6.6.6.1(I) NFPA 58. INDICATE THE TYPE OF PROTECTION AND | | | HOW IT WILL BE TESTED- SECTION 6.17.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-20 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-18 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-16 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-27 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-09-25 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2020-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-01 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-11-17 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-11-17 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-28 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-28 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-09-24 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-09-24 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-11-24 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-24 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2020-11-24 09:19:08 | GENERATOR CONCRETE PAD DWG WITH ENGINEER'S EMBOSSED | | | SEAL AND ORIGINAL SIGNATURE MATCHES APPROVED ONE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-11-20 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-11-20 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2020-11-20 13:39:09 | THE PREFABRICATED GENERATOR PAD DRAWINGS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ENGINEER. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 | | | CONTRACTOR SIGNATURE VERIFIED ON LOAD CALC'S AND | | | ELECTRICAL RISER. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-11-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2020-11-17 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2020-11-17 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2020-11-17 15:35:00 | SIGNATURE REVIEW | | | 11/17/2020 | | | | | | THE PREFABRICATED GENERATOR PAD DRAWINGS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ENGINEER. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 471 & SECTION 61G15-23.005 | | | FAC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-10-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-10-08 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-10-08 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2020-10-08 08:27:12 | THE PREFABRICATED GENERATOR PAD DRAWINGS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ENGINEER. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-09-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2020-09-23 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2020-09-23 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2020-09-23 12:35:18 | THE PREFABRICATED GENERATOR PAD DRAWINGS ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ENGINEER. ELECTRONICALLY | | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ENGINEER'S | | | DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO | | | SUBMIT THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. | | | AFTER THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN | | | SUBMIT THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING | | | DEPARTMENT TO BE VERIFIED. THE ENGINEER'S ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | | SIGNATURE ARE ACCEPTABLE. FS 471 & 61G15 | | 2020-09-05 06:51:23 | CONTRACTOR SIGNATURE VERIFIED ON LOAD CALC'S AND | | | ELECTRICAL RISER. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-10-26 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-10-26 |
Time |
11:59 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-09-17 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-09-17 |
Time |
16:55 |
Sent To |
I |
|
| Notes |
| 2020-09-17 16:58:58 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. GENERATOR EQUIPMENT ENCROACHES TOO FAR INTO REQUIRED | | | SETBACK. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING | | | AND LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT PROJECT MORE | | | THAN 4 FEET INTO A REQUIRED SETBACK. | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED GENERATOR | | | EQUIPMENT TO REAR PROPERTY LINE | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | |
|
|