| Plan Review Stops For Permit 20081288 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-11-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-11-18 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-11-18 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-27 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-24 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2020-09-25 08:45:57 | PLAN REVIEW GENERATOR / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. GENERATOR SPECIFICATIONS SUBMITTED FOR REVIEW ARE | | | FOR A 2016 MODEL GENERAC 22KW GENERATOR. | | | PROVIDE CURRENT GENERATOR SPECIFICATIONS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. DESIGN PRESSURES CALCULATED ON GENERATOR PAD | | | ENGINEERING (53.19) ARE NOT REALISTIC FOR THIS SITE AND | | | WOULD NOT ALLOW THE PROPOSED GENERATOTR PAD WITH A | | | MAXIMUM ALLOWABLE DESIGN PRESSURE OF (47.44) TO BE | | | ALLOWED. | | | MY ESTIMATED DESIGN PRESSURES FOR THIS SITE WOULD BE | | | BASED ON VULT OF 170MPH AND VASD OF 138MPH WITH A RISK | | | CAT. II AND EXPOSURE C PROVIDING A DESIGN PRESSURE OF | | | 39.09 FOR PALM BEACH COUNTY. THIS WOULD ALLOW THE | | | PROPOSED GENERATOR PAD TO BE USED. | | | PLEASE HAVE YOUR DESIGNER RE-VISIT THESE CALCULATIONS | | | FOR THE GENERATOR PAD. | | | R301.2.1 WIND DESIGN CRITERIA. | | | BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN | | | ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING | | | THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED | | | FROM FIGURE R301.2(4). | | | | | | | | | NOTICE: GENERATOR PAD ELEVATION | | | | | | THIS SITE IS LOCATED WITHIN A SPECIAL FLOOD HAZARD AREA | | | (SFHA) AE WITH A BASE FLOOD ELEVATION (BFE) OF 7'-0" | | | NAVD. THE HOUSE WAS CONSTRUCTED USING THE EXISTING BFE | | | OF 7'-0" NGVD. | | | LOCAL FLOODPLAIN MANAGEMENT OFFICIALS ARE REQUIRED TO | | | ENSURE THAT ALL MACHINERY AND EQUIPMENT SERVICING THE | | | BUILDING ARE PROTECTED FROM FLOODING PER R322.1.6 | | | PROTECTION OF MECHANICAL, PLUMBING AND ELECTRICAL | | | SYSTEMS. | | | MACHINERY OR EQUIPMENT SERVICING THE BUILDING SHALL BE | | | LOCATED AT OR ABOVE THE BASE FLOOD ELEVATION (BFE) AT | | | TIME OF NEW RESIDENTIAL CONSTRUCTION. | | | GENERATOR PAD SHALL BE SET AT THE FINISHED FLOOR | | | ELEVATION OF THE RESIDENCE. (7'-0" NGVD). | | | | | | | | | | | | | | 2020-08-31 06:57:24 | SFHA - LOCATION OF GENERATOR IS IN ZONE AE WITH A BFE | | | 6.0 FEET. NAVD. CT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-27 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-27 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-31 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-31 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2020-08-31 07:31:55 | NO NOTES |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-26 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-26 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2020-10-26 15:25:33 | 10/26/20 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-02 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-02 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2020-09-02 15:45:56 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20081288 | | | | | | CODES IN EFFECT: | | | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) ON THE GAS RISER DIAGRAM SHEET: NOTE 4 INDICATES | | | ?PIPE SIZED BASED ON THE LONGEST LENGTH METHOD? BUT IT | | | DOES NOT GIVE US THE LONGEST LENGTH TO THE MOST REMOTE | | | APPLIANCE FROM THE GAS METER. PLEASE PROVIDE THE LENGTH | | | AS WE CANNOT SIZE THIS SYSTEM UNTIL WE HAVE THAT | | | NUMBER. FBC FG 402.4.2 | | | | | | 2) PIPE SECTION (A) IS SUPPLYING THE EXISTING GAS | | | SYSTEM AND THE NEW GAS LINE TO THE GENERATOR. WE MUST | | | HAVE THE LONGEST LENGTH TO THE MOST REMOTE APPLIANCE | | | BEFORE WE CAN SIZE THIS SECTION OF PIPE TO DETERMINE | | | THAT IS CAN SUPPLY THE NEW LOAD. FBC FG 402.4.2 | | | | | | 3) THE NEW REGULATOR TO THE GENERATOR HAS A NOTE | | | INDICATING SECTION 410.10, PLEASE CHECK THESE NUMBERS | | | AS THERE IS NO SECTION 410.10 IN THE 2017 FBC FG. | | | | | | 4) THE NEW GAS LINE TO THE NEW GENERATOR HAS A | | | MEASUREMENT OF 20?. WE DO NOT USE THIS NUMBER TO SIZE | | | THE PIPE SUPPLYING GAS TO THE GENERATOR UNLESS IT IS IN | | | FACT THE DISTANCE FOR THE MOST REMOTE APPLIANCE FROM | | | THE GAS METER. AS THERE ARE NO MEASUREMENTS INDICATED | | | ON THE GAS RISER FOR THE EXISTING PIPING SYSTEM I HAVE | | | NO WAY OF KNOWING HOW TO SIZE THIS GAS SYSTEM. PLEASE | | | SHOW LENGTHS TO THE EXISTING GAS APPLIANCES SO WE CAN | | | COME UP WITH THE DISTANCE TO THE MOST REMOTE APPLIANCE | | | FROM THE GAS METER. FBC FS 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-12-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-12-14 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-11-24 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-20 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-11-10 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-15 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-27 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-10-26 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-10-26 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-02 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-02 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-11-10 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-11-10 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2020-11-10 15:03:15 | ROUTED ORIGINAL S&S ENGINEERING TO STORAGE | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2020-11-10 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2020-11-10 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2020-11-10 12:26:57 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | RE: SIGNATURE DOCUMENTS SUBMITTED 10/22 | | | THE ENGINEERING SUBMITTED IS NOT THE SAME AS THE | | | ENGINEERING UPLOADED TO PROJECTDOX. IT IS NOT CLEAR | | | WHICH SLAB DETAIL IS THE PROPOSED INSTALLATION. IF THE | | | ONE UPLOADED TO PROJECTDOX IS THE SLAB PROPOSED, PLEASE | | | SUBMIT THE ORIGINAL (SEE OPTIONS BELOW). IF THE NEW | | | SLAB DETAIL IS PROPOSED, PLEASE ADVISE AND IT WILL BE | | | SCANNED, UPLOADED, AND ROUTED FOR REVIEW. | | | | | | ********************************************** | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL (OR DROP OFF) ONE ORIGINAL | | | SIGNED AND SEALED PAPER ORIGINAL WITH A WET SIGNATURE | | | TO: | | | | | | SAMANTHA M. HILL | | | CHIEF PLANS EXAMINER | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6724. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2020-11-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-10-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-10-27 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2020-11-05 10:10:55 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: GENERATOR PAD ENGINEERING | | | | | | DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET / DIGITAL SIGNATURE IS | | | NOT CONSIDERED A DIGITAL SIGNATURE. | | | | | | EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF | | | (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND | | | SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2020-09-25 08:18:52 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: GENERATOR PAD ENGINEERING | | | | | | DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, | | | DATED ORIGINALS. A SCAN OF A WET / DIGITAL SIGNATURE IS | | | NOT CONSIDERED A DIGITAL SIGNATURE. | | | | | | EITHER UPLOAD A DIGITALLY SIGNED DOCUMENT OR DROP OFF | | | (OR MAIL) ONE PAPER ORIGINAL WITH A WET SEAL AND | | | SIGNATURE TO: | | | | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST | | | WEST PALM BEACH, FL 33401 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2020-09-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-02 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-02 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2020-09-02 06:41:23 | DIGITAL SIGNATURE VERIFIED ON ELECTRICAL PLAN. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2020-12-09 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-12-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-12-09 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2020-11-19 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-11-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-11-19 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-11-19 12:08:01 | ADDRESS PREVIOUS ZONING COMMENTS. PLEASE PROVIDE AN | | | UPDATES SURVEY SHOWING THE LOCATION OF THE GENERATOR | | | WITH APPROVED SETBACKS FROM ALL PROPERTY LINES. SEE | | | FIRST ZONING COMMENTS FOR SPECIFICS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-10-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-10-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-10-27 09:24:19 | ADDRESS PREVIOUS ZONING COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-09-09 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-09-09 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-09-09 09:03:44 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 9/9/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE PROPOSED GENERATOR ENCROACHES MORE THAN 4 FEET | | | INTO THE REQUIRED SETBACK. PURSUANT THE CITY OF WEST | | | PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS | | | (ZLDRS), SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY | | | NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | THE REQUIRED REAR SETBACK FOR THIS PROPERTY IS 15 FEET, | | | THE GENERATOR MUST BE SETBACK A MINIMUM OF 11 FROM THE | | | REAR PROPERTY LINE. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOGIN | | | INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | W: WPB.ORG |
|
|