| Plan Review Stops For Permit 20081232 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-10 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-10 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-10 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-10 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2020-11-10 09:09:44 | WOOD DECK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) PLEASE PROVIDE THE STRUCTURAL CALCULATIONS FOR THE | | | GUARD RAILS TO COMPLY WITH FBC 1607.8.1.1 CONCENTRATED | | | LOAD. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST | | | A CONCENTRATED LOAD OF 200 POUNDS (0.89 KN) IN | | | ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. OR HAVE THE | | | ARCHITECT OR ENGINEER WHO DESIGNED THE GUARD RAIL SIGN | | | AND SEAL THE DRAWINGS. | | | 2) GUARD RAIL DRAWINGS SHOW ATTACHMENT TO CONCRETE - | | | PLEASE PROVIDE DETAILS FOR ATTACHMENT TO WOOD. | | | | | | FYI = SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO | | | BE DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-16 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-16 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2020-10-16 15:33:11 | WOOD DECK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) ARCHITECTURAL DRAWINGS SHOULD SHOW THE CODE VERSION | | | AND THE WIND DESIGN CRITERIA USED FOR DESIGN - (CODE | | | VERSION, WIND SPEED, EXPOSURE, RISK CATEGORY) FBC | | | 1603.1.4 | | | 2) DRAWINGS STATE THAT GUARD RAILS ARE NOT PART OF | | | THIS. ARE THE GUARD RAILS BEING REPLACED? IF SO PLEASE | | | PROVIDE SIGNED AND SEALED GUARD RAIL DETAILS FROM AN | | | ARCHITECT OR ENGINEER OR PROVIDE A MIAMI DADE OR | | | FLORIDA STATE PRODUCT APPROVAL FOR THE GUARD RAILS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-24 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-24 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2020-09-24 10:28:08 | DECK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWINGS NEED TO BE MORE DETAILED SHOWING WHICH | | | SUPPORT BOARDS WERE REPLACED - DIMENSIONS AND LENGTH OF | | | BOARDS - ATTACHMENT OF BOARDS TO STRUCTURE (CLIP | | | DESIGNATION AND SIZE AND AMOUNT OF FASTENERS) . SHOW IF | | | RAILING IS AFFECTED. | | | 2) THE DECK IS SUBJECT TO LIVE LOADS, DEAD LOADS AND | | | WIND LOADS PER FBC R301.1 PLEASE PROVIDE THE STRUCTURAL | | | CALCULATIONS REQUIRED FOR THESE LOADS OR HAVE THE | | | DETAILS PREPARED AND SIGNED AND SEALED BY AN ARCHITECT | | | OR ENGINEER FBC R301.1.3 | | | 3) PLEASE SHOW THE WIND DESIGN DATA PER FBC R301.2.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-11-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-11-04 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-11-04 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-10-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2020-10-19 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2020-10-19 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-10 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-04 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-11-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-11-10 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-11-02 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-10-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2020-10-27 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2020-10-08 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-24 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-09 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2020-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-12-10 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-12-10 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-11-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2020-11-02 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2020-11-02 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2020-11-02 15:46:46 | DRAWINGS 1 OF 3, 2 OF 3 AND 3 OF 3 DATED 10/22/2020 | | | HAVE ARCHITECT'S EMBOSSED SEAL AND ORIGINAL SIGNATURE. | | | JG. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-10-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-10-16 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-10-16 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2020-10-16 15:35:51 | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. | | | DRAWINGS DO NOT SHOW IN "ADOBE READER" AS | | | DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR | | | ARCHITECT OR ENGINEER DOES NOT HAVE AN ELECTRONIC OR | | | DIGITAL SIGNATURE - PLEASE DROP OFF (CITY HALL DROP | | | BOX) THE ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS | | | ALONG WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE | | | REASON FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN | | | REVIEW REQUEST FORM CAN BE OBTAINED BY E MAILING | | | [email protected] AND ASKING FOR THE FORM. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2020-09-24 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2020-09-24 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2020-09-24 10:29:08 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-10-26 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-10-23 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-10-23 |
Time |
08:15 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2020-09-21 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-09-21 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-09-21 |
Time |
10:25 |
Sent To |
I |
|
| Notes |
| 2020-09-21 10:27:57 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: | | | ________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1.PROVIDE A CURRENT SURVEY, WHICH INCLUDES THE | | | PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. PLEASE | | | ILLUSTRATE THE FOLLOWING ON THE SURVEY: | | | - LOCATION OF PROPOSED DECK | | | - DISTANCE FROM DECK TO PROPERTY LINES | | | | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD | | | LIKE TO RESUBMIT ELECTRONICALLY, EMAIL | | | [email protected] AND REQUEST TO HAVE YOUR | | | PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG | | | IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL. | | | PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU | | | ARE FINISHED UPLOADING. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | KIZZI ALEXANDRE, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1442 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|