| 2020-10-16 13:18:40 | 1ST REVIEW FBC-2017 PLUMBING |
| | PERMIT- 20081228 |
| | 10/16/2020 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A1.0: SHOW THE CLEAR FLOOR SPACE DIAGRAMS AND |
| | DIMENSIONS FOR THE DRINKING FOUNTAIN AND BREAKROOM |
| | SINK- SECTIONS 305.3 & 305.5 FBC ACC. |
| | |
| | 2) A1.0: SHOW THE DEPTH DIMENSION OF THE DF ALCOVE- |
| | SECTION 305.7 FBC ACC. |
| | |
| | 3) A3.4: PROVIDE DETAILS SHOWING THE DF KNEE AND TOE |
| | CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS- SECTION |
| | 602.2 FBC ACC. |
| | |
| | 4) A3.4: PLEASE PROVIDE THE FOLLOWING MISSING |
| | ACCESSIBILITY DETAILS. |
| | |
| | A) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORY- |
| | SECTION 606.2. |
| | B) SHOW THE COMPLETE ARC OF THE DOOR TO VERIFY IT WILL |
| | NOT SWING INTO THE CLEAR FLOOR SPACE FOR THE LAVATORY- |
| | SECTION 602.2.3 FBC ACC. |
| | C) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED |
| | FLOOR- SECTION 604.4. |
| | D) HEIGHTS OF THE FRONT RIM OF THE LAVATORIES FROM THE |
| | FINISHED FLOORS- SECTION 606.3 |
| | E) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION |
| | 306. |
| | H) GRAB BAR LENGTHS, SPACINGS FROM ADJACENT WALLS, AND |
| | MOUNTING HEIGHTS FROM THE FINISHED FLOOR TO THE TOP OF |
| | THE GRIPPING SURFACES- SECTION 604.5 & 609.4 |
| | J) THE CENTERLINES OF THE TOILET PAPER DISPENSERS |
| | MEASURED FROM THE FRONT EDGES OF THE WATER CLOSETS- |
| | SECTION 604.7. |
| | L) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO |
| | THE BOTTOM OF THE REFLECTIVE SURFACE- SECTION 603.3. |
| | |
| | 5) INDICATE THE TYPE AND DIMENSIONS OF WALL BACKING |
| | MATERIAL TO BE INSTALLED AT THE MOP SINK- SECTION 310.3 |
| | FBC P AND SECTION 1210.2.2 FBC B. |
| | |
| | 6) P0.0: PROVIDE THE EFFICIENCY RATING OF THE WATER |
| | HEATER AND SUBMIT A MANUFACTURER'S SPEC SHEET TO VERIFY |
| | COMPLIANCE WITH TABLE C404.2 FBC EC. |
| | |
| | 7) P0.0: PROVIDE A DEVICE SCHEDULE SHOWING MAKES, |
| | MODELS AND LISTINGS FOR THE WATER HAMMER ARRESTORS, |
| | MIXING VALVES, BACKFLOW PREVENTERS, AND TRAP PRIMERS- |
| | SECTIONS 604.9, 607.1.2, 608.1, & 1002.4.1.1 FBC P. |
| | |
| | 8) P2.0: SHOW THE LOCATION OF THE REQUIRED CLEANOUT AT |
| | THE JUNCTION OF THE BUILDING DRAIN AND BUILDING SEWER |
| | LINE- SECTION 708.1.3 FBC P. |
| | |
| | 9) P2.0: PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1 |
| | WPB. SHOW THE WIDTH OF THE REPAIR; THE MINIMUM |
| | THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED; THE |
| | SIZE, SPACING, AND EMBEDMENT DEPTH OF THE DOWELS; AND |
| | THE ANCHORING MATERIAL FOR THE DOWELS. THE REPAIR SHALL |
| | ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AND THE |
| | REQUIRED VAPOR BARRIER OVER WELL-COMPACTED SOIL. PLEASE |
| | NOTE A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE |
| | FOR FINAL INSPECTION APPROVAL. |
| | |
| | 10) P4.0: THE LOCATIONS OF THE TRAP PRIMERS FOR THE |
| | FLOOR DRAINS IN THE RESTROOMS ARE NOT CLEARLY |
| | IDENTIFIED- SECTION 1002.4.1.1 FBC P. |
| | |
| | 11) SUBMIT A PLUMBING SUB-PERMIT APPLICATION AS |
| | REQUIRED BY SECTION 105.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |