| Plan Review Stops For Permit 20081223 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-14 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-14 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2021-01-14 10:44:30 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | THE POOL BARRIER MUST BE IN ACCORDANCE WITH THE | | | PROVISIONS FOR POOL BARRIERS FOUND AT SECTION FBC R | | | 4501.17 OF THE FLORIDA BUILDING CODE (RESIDENTIAL). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-04 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-04 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2021-01-04 16:51:44 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC R 4501.17.1 ? 4501.17.3, IDENTIFY THE LOCATION & | | | TYPE OF CHILD BARRIERS TO BE USED AS PER CODE | | | REQUIREMENTS: (PERIMETER YARD FENCE, SCREEN ENCLOSURE, | | | CHILD BARRIER, WINDOW/DOOR ALARMS). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-11-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-14 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-13 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2020-11-14 10:17:32 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1) FBC B 107.2.1, THE SUBMITTEDPLANS INDICATE A FOOTING | | | DETAIL FOR PAVERS AND/OR A FOOTING DETAIL FOR A SCREEN | | | ENCLOSURE. PLEASE PROVIDE (ON PLAN) THE LOCATION AND | | | TYPE OF FOOTINGS TO BE USED. | | | (SCREEN ENCLOSURE WILL REQUIRE A SEPARATE PERMIT). | | | 2) FBC R 4501.17.1 - 4501.17.3, IDENTIFY THE LOCATION & | | | TYPE OF CHILD BARRIERS TO BE USED AS PER CODE | | | REQUIREMENTS: (PERIMETER YARD FENCE, SCREEN ENCLOSURE, | | | CHILD BARRIER, WINDOW/DOOR ALARMS). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-11-20 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2020-11-20 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2020-11-20 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-14 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-05 |
Time |
18:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-04 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-12-22 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-11-24 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-11-12 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2020-11-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2020-11-16 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2020-11-16 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2020-11-16 11:48:41 | 11/16/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES | | | FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, | | | STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT | | | THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK | | | OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2021-01-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-14 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-14 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2021-01-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2021-01-04 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2021-01-04 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2021-01-04 16:54:18 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW DENIED: | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561?805?6673. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-11-14 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2020-11-14 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2020-11-13 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2020-11-14 10:20:26 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW DENIED: | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | | | | EITHER EMAIL A DIGITALLY OR ELECTRONICALLY SIGNED PLAN | | | TO ME, OR YOU CAN MAIL ONE ORIGINAL SIGNED AND SEALED | | | PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6673. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-11-24 |
|
|
Cont ID |
|
| Sent By |
kalexand |
Date |
2020-11-24 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
kalexand |
Date |
2020-11-24 |
Time |
08:27 |
Sent To |
I |
|
| Notes |
|
|