| Plan Review Stops For Permit 20081133 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-17 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-17 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2020-09-17 12:01:55 | PLAN REVIEW GENERATOR / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW. | | | | | | 1. THE GENERATOR SPECIFICATIONS PROVIDED ARE | | | INCOMPLETE. THE GENERATOR SIZE AND WEIGHT ARE REQUIRED | | | TO VERIFY COMPLIANCE WITH THE GENERATOR PAD | | | REQUIREMENTS. | | | THE GENERATOR PAD SCHEDULE SPECIFIES THE MINIMUM | | | GENERATOR SIZE, WEIGHT AND DSIGN WIND LOADS REQUIRED. | | | SEE NOTE AT THE BOTTOM OF PAGE 5 OF THE GENERATOR | | | SPECIFICATIONS PROVIDED. | | | | | | | | | 2. PROVIDE SITE SPECIFIC DESIGN WIND LOADS FOR THE | | | GENERATOR PER NOTE #2 OF ALLOWABLE DESIGN PRESSURE | | | REQUIREMENT OF THE GENERATOR PAD. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-15 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-15 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2020-09-15 09:31:17 | PLAN REVIEW GENERATOR / BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE GENERATOR SPECIFICATIONS PROVIDED ARE | | | INCOMPLETE. THE GENERATOR SIZE AND WEIGHT ARE REQUIRED | | | TO VERIFY COMPLIANCE WITH THE GENERATOR PAD | | | REQUIREMENTS. | | | THE GENERATOR PAD SCHEDULE SPECIFIES THE MINIMUM | | | GENERATOR SIZE, WEIGHT AND DSIGN WIND LOADS REQUIRED. | | | SEE NOTE AT THE BOTTOM OF PAGE 5 OF THE GENERATOR | | | SPECIFICATIONS PROVIDED. | | | | | | | | | 2. PROVIDE SITE SPECIFIC DESIGN WIND LOADS FOR THE | | | GENERATOR PER NOTE #2 OF ALLOWABLE DESIGN PRESSURE | | | REQUIREMENT OF THE GENERATOR PAD. | | | | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | | | 2020-08-29 10:10:09 | ELECTRICAL LOAD CALCS AND RISER REQUIRE CONTRACTORS | | | SIGNATURE. CT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2020-09-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-08-29 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-29 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2020-08-29 10:21:09 | NO NOTES |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-17 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-17 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2020-09-17 12:31:24 | PREVISIO: INSTALLER OF TANK MUST HAVE TANK SECURING | | | SPECS ON SITE FOR THE INSPECTOR. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-10 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-10 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2020-09-10 12:08:04 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT-20081133 | | | | | | CODES IN EFFECT: | | | | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH | | | EDITION 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE A GAS RISER DIAGRAM SHOWING THE TANK, | | | BURIAL DEPTH TRACER WIRE AND WARNING TAPE. PLEASE SHOW | | | THE PIPING, MATERIAL OF PIPING, ANODELESS RISERS, | | | PROVIDE THE SPECS FOR THE REGULATORS USED (HIGHLIGHT | | | ALL MATERIAL THAT APPLIES TO THIS JOB IN THE SPEC | | | SHEETS). PROVIDE THE TYPE OF GAS LINE MATERIAL USED | | | ALONG WITH THE DISTANCE FROM TANK TO GENERATOR. SHOW | | | ALL SHUT OFF VALVES, UNIONS AND REGULATORS ON RISER | | | DIAGRAM. SHOW OPERATING PRESSURES ON RISER DIAGRAM. FBC | | | FS 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD | | | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER | | | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN | | | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS | | | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS | | | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR | | | UPDATED. | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2020-09-28 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2020-09-17 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
ccarvaja |
Date |
2020-09-17 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
ccarvaja |
Date |
2020-09-16 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-15 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-08-27 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2020-09-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2020-09-10 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2020-09-10 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2020-09-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-25 |
Time |
14:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2020-09-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-17 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-17 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2020-09-17 12:04:17 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW. | | | | | | RE: ELECTRICAL RISER AND LOAD CALC'S. | | | | | | NON-DESIGN PROFESSIONALS | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | | TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR | | | AUTHORITY | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | 2. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH | | | SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED | | | NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | OPTION | | | | | | YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH | | | VALID SIGNATURE OF CONTRACTOR OR DESIGNER PRIOR TO | | | PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL | | | FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT | | | SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR | | | INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND | | | IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU | | | TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2020-09-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2020-09-08 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2020-09-08 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2020-09-08 13:52:20 | PLAN REVIEW / SIGNATURES | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | RE: ELECTRICAL RISER AND LOAD CALC'S. | | | | | | NON-DESIGN PROFESSIONALS | | | | | | 1. THE CONTRACTOR OR DESIGNER OF RECORD SHALL PROVIDE A | | | TITLE BLOCK AND SIGNATURE ON PLAN SHEETS UNDER THEIR | | | AUTHORITY | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | | | | | | | 2. UPLOAD DOCUMENTS VIA THE PROJECTDOX PORTAL WITH | | | SIGNATURE OF DESIGNER AS APPLICABLE; USE THE REQUIRED | | | NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | | | | OPTION | | | | | | YOU MAY ELECT TO PROVIDE A HARD COPY OF PLANS WITH | | | VALID SIGNATURE OF CONTRACTOR OR DESIGNER PRIOR TO | | | PERMIT. A DROP BOX HAS BEEN INSTALLED OUTSIDE CITY HALL | | | FOR THIS PURPOSE. CONTACT THE OFFICE OF DEVELOPMENT | | | SERVICES @ 561-805-8700 OR [email protected] TO STATE YOUR | | | INTENTIONS. CITY STAFF WILL REVIEW YOUR DOCUMENTS AND | | | IF APPROVED YOU WILL RECIEVE AN E-MAIL INSTRUCTING YOU | | | TO DOWNLOAD AND PRINT YOUR PERMIT AND PLANS. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2020-09-28 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-09-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
rthermid |
Date |
2020-09-28 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-09-28 07:33:33 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 9/28/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THE PROPOSED TANK MUST BE UNDERGROUND | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2020-09-09 |
|
|
Cont ID |
|
| Sent By |
rthermid |
Date |
2020-09-09 |
Time |
|
Rev Time |
|
| Received By |
rthermid |
Date |
2020-09-09 |
Time |
|
Sent To |
I |
|
| Notes |
| 2020-09-09 08:55:06 | ZONING PLAN REVIEW | | | ________________________________________ | | | | | | DATE OF REVIEW: 9/9/2020 | | | ________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. THE PROPOSED TANK MUST BE UNDERGROUND | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | RAFAELA THERMIDOR, ASSOCIATE PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG |
|
|