Plan Review Details - Permit 20081095
Plan Review Stops For Permit 20081095
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-11-04 Cont ID  
Sent By cthroop Date 2020-11-04 Time 09:33 Rev Time 0.00
Received By cthroop Date 2020-11-04 Time 08:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 13:09 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 11:53 Sent To  
Notes
2020-09-08 13:09:53PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE ONLY: VALUE INCREASED FROM $170,000 TO $200,834
 BASED ON THE ICC BUILDING VALUATION TABLES.
  
  
 1. PROVIDE WINDOW AND DOOR SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE PRODUCT APPROVALS FOR WINDOWS AND EXTERIOR
 DOORS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
 OPTION:
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-10-28 Cont ID  
Sent By equinone Date 2020-10-28 Time 13:25 Rev Time 0.00
Received By equinone Date 2020-10-28 Time 13:25 Sent To  
Notes
2020-10-28 13:25:59FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 ENRIQUE QUINONEZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6746
 [email protected]
  
 1ST REVIEW:
  
 1. SMOKE DETECTORS MISSING INSIDE BEDROOM #2, OUTSIDE
 BEDROOM #2, OUTSIDE BEDROOM #3 AND OUTSIDE MASTER
 BEDROOM PER R314.3.
 R314.3 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1.IN EACH SLEEPING ROOM.
 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
 2. PROVIDE LUMINAIRE AND OUTLET FOR MECHANICAL
 EQUIPMENT IN ATTIC PER M1305.1.3.1.
 PROVIDE GFCI PROTECTED OUTLET AND SWITCH CONTROLLED
 LIGHT FOR SERVICING EACH AHU LOCATED IN AN ATTIC. FBC
 MECHANICAL CODE M306.3.1
  
 2ND REVIEW:
  
 1. SMOKE DETECTORS MISSING INSIDE BEDROOM #2, OUTSIDE
 BEDROOM #2, OUTSIDE BEDROOM #3 AND OUTSIDE MASTER
 BEDROOM PER R314.3.
 R314.3 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1.IN EACH SLEEPING ROOM.
 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
 COMPLETED.
  
 2. PROVIDE LUMINAIRE AND OUTLET FOR MECHANICAL
 EQUIPMENT IN ATTIC PER M1305.1.3.1.
 PROVIDE GFCI PROTECTED OUTLET AND SWITCH CONTROLLED
 LIGHT FOR SERVICING EACH AHU LOCATED IN AN ATTIC. FBC
 MECHANICAL CODE M306.3.1
  
 COMPLETED
  
 ENRIQUE QUINONEZ
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 13:09 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 11:54 Sent To  
Notes
2020-09-08 13:10:42PLAN REVIEW / ELECTRICAL
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SMOKE DETECTORS MISSING INSIDE BEDROOM #2, OUTSIDE
 BEDROOM #2, OUTSIDE BEDROOM #3 AND OUTSIDE MASTER
 BEDROOM PER R314.3.
 R314.3 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
 1.IN EACH SLEEPING ROOM.
 2.OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
 2. PROVIDE LUMINAIRE AND OUTLET FOR MECHANICAL
 EQUIPMENT IN ATTIC PER M1305.1.3.1.
 PROVIDE GFCI PROTECTED OUTLET AND SWITCH CONTROLLED
 LIGHT FOR SERVICING EACH AHU LOCATED IN AN ATTIC. FBC
 MECHANICAL CODE M306.3.1
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 13:08 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 13:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-11-04 Cont ID  
Sent By ccarvaja Date 2020-11-04 Time 10:17 Rev Time 0.00
Received By ccarvaja Date 2020-10-20 Time 07:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-25 Cont ID  
Sent By shill Date 2020-09-25 Time 11:04 Rev Time 0.00
Received By shill Date 2020-08-26 Time 16:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-11-23 Cont ID  
Sent By lmarchan Date 2020-11-23 Time 08:10 Rev Time 0.00
Received By lmarchan Date 2020-11-04 Time 10:17 Sent To  
Notes
2020-11-20 11:41:37RECEIPT - MU-2020-43453 - $11,623.07 - PAID
2020-11-04 10:18:2211/04/20 EMAILED PBC TO REVIEW, IMPACT FEES
 QUESTIONNAIRE UPLOADED IN PROJECTDOX. CC

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 13:07 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 11:53 Sent To  
Notes
2020-09-08 13:07:48IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 14:36 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 14:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2020-09-04 Cont ID  
Sent By medwards Date 2020-09-04 Time 13:34 Rev Time 0.00
Received By medwards Date 2020-09-04 Time 13:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-10-27 Cont ID  
Sent By lcrespo Date 2020-10-27 Time 12:22 Rev Time 0.00
Received By lcrespo Date 2020-10-27 Time 12:22 Sent To  
Notes
2020-10-27 12:22:2810/27/20 REVIEWED FOR CODE COMPLIANCE (PLUMBING)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS, OR THEIR REPRESENTATIVES
 FROM THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL,
 STATE, AND NATIONAL CODES AND STANDARDS IN EFFECT AT
 THE TIME OF PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK
 OF EVERY ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-09-01 Cont ID  
Sent By abelisle Date 2020-09-01 Time 15:33 Rev Time 0.00
Received By abelisle Date 2020-09-01 Time 15:22 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2020-11-04 Cont ID  
Sent By cthroop Date 2020-11-04 Time 09:33 Rev Time 0.00
Received By cthroop Date 2020-11-04 Time 08:39 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By cthroop Date 2020-09-08 Time 13:08 Rev Time 0.00
Received By cthroop Date 2020-09-08 Time 11:54 Sent To  
Notes
2020-09-08 13:08:36PLAN REVIEW / ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NEC 2014
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING SUB-PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING
 SYSTEM COMPONENTS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 OPTION:
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-10-27 Cont ID  
Sent By medwards Date 2020-10-27 Time 14:36 Rev Time 0.00
Received By medwards Date 2020-10-27 Time 14:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By medwards Date 2020-09-08 Time 12:19 Rev Time 0.00
Received By medwards Date 2020-09-04 Time 13:39 Sent To  
Notes
2020-09-04 13:44:471ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20081095
  
 CODES IN EFFECT:
  
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) OUR SYSTEM SAYS THAT ALL SHEETS SIGNED AND SEALED BY
 SCOTT BLAKESLEE DISHER ARE INVALID. PLEASE CORRECT AND
 RESUBMIT SIGNATURES AND SEALS. PER THE WPB AMENDMENTS
 TO THE FBC, EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED
 AND SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A
 DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH THE
 PROPER THIRD PARTY VERIFICATION. PROVIDE CORRECTION.
 ALTERNATIVELY, A SIGNED/SEALED PAPER SET MAY BE
 SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL TRADES ARE
 APPROVED. WPB FBC 107.1; FS 471/481
 2) THE DESIGNER OF THE TRUSS DRAWINGS NEEDS TO
 DIGITALLY SIGN AND SEAL THE DRAWINGS. SEE ABOVE.
  
 3) DESIGNER OF ENERGY CALCS 3 MUST DIGITALLY SIGN AND
 SEAL DOCUMENTS. SEE ABOVE.
  
 4) THE GEO RPT MUST HAVE A DIGITAL SIGNATURE AND SEAL.
 SEE ABOVE
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2020-09-22 Cont ID  
Sent By rthermid Date 2020-09-22 Time   Rev Time  
Received By rthermid Date 2020-09-22 Time   Sent To I
Notes
2020-09-22 10:30:36SEPERATE PERMIT REQUIURED FOR THE DRIVEWAY,
 KEEP IN MIND THAT THE MAX DRIVEWAY WIDTH IS 20FEET; AND
 75% OF THE FRONT YARD MUST BE LANDSCAPE.