Plan Review Details - Permit 20081079
Plan Review Stops For Permit 20081079
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-09-22 Cont ID  
Sent By rmcphers Date 2020-09-22 Time 14:47 Rev Time 0.00
Received By rmcphers Date 2020-09-22 Time 14:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-09-24 Cont ID  
Sent By jgomez Date 2020-09-24 Time 14:52 Rev Time 0.00
Received By jgomez Date 2020-09-24 Time 14:24 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-09-24 Cont ID  
Sent By lmarchan Date 2020-09-24 Time 10:30 Rev Time 0.00
Received By lmarchan Date 2020-09-23 Time 14:59 Sent To  
Notes
2020-09-24 05:58:59DOCUMENTS RECEIVED THROUGH DROP BOX ROUTED TO "S4"
 SPALMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-22 Cont ID  
Sent By rmcphers Date 2020-09-22 Time 14:49 Rev Time 0.00
Received By rmcphers Date 2020-09-02 Time 10:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2020-09-24 Cont ID  
Sent By medwards Date 2020-09-24 Time 08:57 Rev Time 0.00
Received By medwards Date 2020-09-24 Time 08:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2020-09-08 Cont ID  
Sent By medwards Date 2020-09-08 Time 08:50 Rev Time 0.00
Received By medwards Date 2020-09-08 Time 07:39 Sent To  
Notes
2020-09-08 08:51:031ST REVIEW FBC-2017 MECHANICAL
 PERMIT-20081079
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) CHANGE OUT FORM STATES THIS IS A MARLEY 200 TON
 COOLING TOWER. IT ALSO STATES THE EXISTING TOWER IS A
 200 TON COOLING TOWER. THE DRAWINGS STATE THIS IS A 175
 TON COOLING TOWER. PLEASE MAKE SURE BOTH DOCUMENTS ARE
 CONSISTENT. PLEASE PROVIDE DRAWINGS SHOWING THE
 CONNECTIONS OF THE NEW TOWER TO THE EXISTING PIPING.
 FBC FS 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD
 SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER
 SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN
 THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS
 PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS
 PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR
 UPDATED.
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2020-09-24 Cont ID  
Sent By jgomez Date 2020-09-24 Time 14:49 Rev Time 0.00
Received By jgomez Date 2020-09-24 Time 14:25 Sent To  
Notes
2020-09-24 14:50:52DRAWINGS M0, M1 AND M2 WITH ENGINEER'S ORIGINAL
 SEAL/SIGNATURE MATCH APPROVED ONES. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2020-09-24 Cont ID  
Sent By medwards Date 2020-09-24 Time 08:58 Rev Time 0.00
Received By medwards Date 2020-09-24 Time 08:57 Sent To  
Notes
2020-09-24 08:59:43PLEASE RESPOND TO 1ST CYCLE SIGNATURE REVIEWER
 COMMENTS.
  
 PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN
 (INCLUDING THE SUPPORTING DOCUMENTS) IS REQUIRED TO BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. ALTERNATIVELY, A SIGNED/SEALED PAPER SET
 MAY BE SUPPLIED TO THE BUILDING DEPARTMENT WHEN ALL
 TRADES ARE APPROVED. WPB FBC 107.1; FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-22 Cont ID  
Sent By rmcphers Date 2020-09-22 Time 14:48 Rev Time 0.00
Received By rmcphers Date 2020-09-22 Time 14:48 Sent To  
Notes
2020-09-22 14:49:24SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW.
 DRAWINGS DO NOT SHOW IN "ADOBE READER" AS
 DIGITALLY/ELECTRONICALLY SIGNED. - OR - IF YOUR
 ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL
 SIGNATURE - PLEASE DROP OFF (CITY HALL DROP BOX) THE
 ORIGINAL SIGNED AND SEALED DRAWINGS/DOCUMENTS ALONG
 WITH A "PLAN REVIEW REQUEST FORM" EXPLAINING THE REASON
 FOR SUBMITTING THE DOCUMENT OR DRAWINGS. PLAN REVIEW
 REQUEST FORM CAN BE OBTAINED BY E MAILING [email protected]
 AND ASKING FOR THE FORM.