Plan Review Details - Permit 20080958
Plan Review Stops For Permit 20080958
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2020-09-09 Cont ID  
Sent By rrossano Date 2020-09-09 Time   Rev Time 0.00
Received By rrossano Date 2020-09-09 Time   Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2020-09-02 Cont ID  
Sent By pleduc Date 2020-09-02 Time   Rev Time 0.00
Received By pleduc Date 2020-09-02 Time 15:46 Sent To  
Notes
2020-09-02 15:53:42UNDERGROUND SHALL COMPLY WITH CITY UTILITIES
 AND PLUMBING CODE AS APPLICABLE
  
 PER NFPA 13D
  
 1.1* SCOPE.
 1.1.1 THIS STANDARD SHALL COVER THE DESIGN,
 INSTALLATION, AND
 MAINTENANCE OF AUTOMATIC SPRINKLER SYSTEMS FOR
 PROTECTION
 AGAINST THE FIRE HAZARDS IN ONE- AND TWO-FAMILY
 DWELLINGS AND
 MANUFACTURED HOMES.
  
 5.3* UNDERGROUND PIPE. ANY TYPE OF PIPE OR TUBE
 ACCEPTABLE
 UNDER THE APPLICABLE PLUMBING CODE FOR UNDERGROUND
 SUPPLY
 PIPE SHALL BE ACCEPTABLE AS AN UNDERGROUND SUPPLY FOR A
 FIRE
 SPRINKLER SYSTEM WHEN INSTALLED BETWEEN THE POINT OF
 CONNECTION
 AND THE SYSTEM RISER.
  
 6.2.3.1 THE CONTROL VALVE SHALL BE PERMITTED TO SERVE
 THE DOMESTIC
 WATER SUPPLY.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-09-09 Cont ID  
Sent By lmarchan Date 2020-09-09 Time 16:12 Rev Time 0.00
Received By lmarchan Date 2020-08-20 Time 10:21 Sent To  
Notes
2020-09-01 10:21:20CONVERTED TO DIGITAL. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2020-09-02 Cont ID  
Sent By medwards Date 2020-09-02 Time 07:02 Rev Time 0.00
Received By medwards Date 2020-09-02 Time 06:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2020-09-03 Cont ID  
Sent By tklarge Date 2020-09-03 Time 14:45 Rev Time 0.00
Received By tklarge Date 2020-09-03 Time 14:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2020-09-30 Cont ID  
Sent By jgomez Date 2020-09-30 Time 10:44 Rev Time 0.00
Received By jgomez Date 2020-09-30 Time 10:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2020-09-01 Cont ID  
Sent By jgomez Date 2020-09-01 Time 10:21 Rev Time 0.00
Received By jgomez Date 2020-09-01 Time 10:21 Sent To  
Notes
2020-09-01 10:30:54FIRE SPRINKLER PLAN AND HYDRAULIC CALCULATIONS NEED THE
 SEAL AND SIGNATURE OF THE ENGINEER OF RECORD.
 NOTE: NEED TO SUBMIT DRAWING AND CALCULATIONS WITH
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS AS REQUIRED BY SEC.
 61G15-23.003 FAC AND CHAPTER 471 F.S.
  
 THERE ARE THERE TWO OPTIONS TO ADDRESS THIS ISSUE:
 (1)SUBMIT PLAN AND CALCULATIONS WITH ENGINEER'S
 ORIGINAL SEAL/SIGNATURE OR
 (2) UPLOAD TO PROJECTDOX PLAN AND CALCULATIONS WITH
 ENGINEER'S DIGITAL SIGNATURE.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  