Plan Review Details - Permit 20080712
Plan Review Stops For Permit 20080712
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-05 Cont ID  
Sent By cthroop Date 2022-05-05 Time 06:50 Rev Time 0.00
Received By cthroop Date 2022-05-05 Time 06:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2020-11-18 Cont ID  
Sent By cthroop Date 2020-11-18 Time 14:45 Rev Time 0.00
Received By cthroop Date 2020-11-18 Time 14:33 Sent To  
Notes
2020-11-18 14:48:26PLAN REVIEW / BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE LOCATION OF ACCESSIBLE PARKING SPACES.
  
 2. PROVIDE LOCATION OF ACCESSIBLE PATH OF TRAVLE FORM
 PUBLIC WAY TO BUILDING ENTRANCE.
  
  
 ACCESSIBLE PARKING
  
 PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING
 INFORMATION PER 208.2
 TOTAL NUMBER OF PARKING SPACES
 NUMBER OF ACCESSIBLE SPACES
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: ?WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN.? HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 206.2.1SITE ARRIVAL POINTS.
 AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN
 THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE
 PASSENGER LOADING ZONES; PUBLIC STREETS AND SIDEWALKS;
 AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE
 BUILDING OR FACILITY ENTRANCE THEY SERVE
  
  
 208.1 GENERAL.
 WHERE PARKING SPACES ARE PROVIDED, PARKING SPACES SHALL
 BE PROVIDED IN ACCORDANCE WITH 208. SEE SECTION 502.5
 REQUIREMENTS FOR VAN PARKING IN STRUCTURES.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-05-04 Cont ID  
Sent By rrossano Date 2022-05-04 Time   Rev Time 0.00
Received By rrossano Date 2022-05-04 Time   Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-08 Cont ID  
Sent By afowlkes Date 2022-06-08 Time 15:21 Rev Time 0.00
Received By afowlkes Date 2022-05-26 Time 15:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-05 Cont ID  
Sent By cthroop Date 2022-05-05 Time 06:50 Rev Time 0.00
Received By cthroop Date 2022-03-08 Time 13:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2020-12-18 Cont ID  
Sent By lmarchan Date 2020-12-18 Time 14:18 Rev Time 0.00
Received By lmarchan Date 2020-11-06 Time 07:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2020-11-18 Cont ID  
Sent By cthroop Date 2020-11-18 Time 14:44 Rev Time 0.00
Received By cthroop Date 2020-11-18 Time 14:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-06-08 Cont ID  
Sent By afowlkes Date 2022-06-08 Time 15:21 Rev Time 0.00
Received By afowlkes Date 2022-06-08 Time 15:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-04-28 Cont ID  
Sent By vbroglia Date 2022-04-28 Time 10:55 Rev Time 0.00
Received By vbroglia Date 2022-04-28 Time 10:55 Sent To  
Notes
2022-04-28 11:07:494/28/22 FAILED
  
 PER SECTION CODE 94-485 (O)(SIZE AND LOCATION OF SPACES
 FOR THE DISABLED-
 PARKING SPACES FOR THE DISABLED SHALL BE DESIGNED AS
 REQUIRED BY THE FOLLOWING:
 A. ALL SPACES SHALL HAVE ACCESS TO A CURB RAMP OR CURB
 CUT, WHEN NECESSARY, TO ALLOW ENTRANCE TO THE BUILDING
 SERVED. SPACES SHALL BE LOCATED SO THAT USERS ARE NOT
 COMPELLED TO WALK OR OTHERWISE MOVE BEHIND PARKED
 VEHICLES, EXCLUDING OTHER VEHICLES PARKED IN ADJACENT
 PARKING SPACES FOR THE DISABLED.
 B. DIAGONAL OR PERPENDICULAR PARKING SPACES SHALL BE A
 MINIMUM OF 12 FEET WIDE AND 18 FEET LONG.
 C. PARALLEL PARKING SPACES SHALL BE LOCATED EITHER AT
 THE BEGINNING OR END OF A BLOCK OR ADJACENT TO ALLEY
 ENTRANCES. CURBS ADJACENT TO SUCH SPACES SHALL BE OF A
 HEIGHT WHICH WILL NOT INTERFERE WITH THE OPENING AND
 CLOSING OF MOTOR VEHICLE DOORS.
  
  
 PER SECTION OF THE CODE 94-485 (G):TRAFFIC CONTROL
 AIDS.
 TRAFFIC CONTROL SIGNS AND PAVEMENT MARKINGS SHALL BE
 USED AS NECESSARY TO ENSURE SAFE AND EFFICIENT TRAFFIC
 OPERATIONS WITHIN ALL PARKING AND LOADING AREAS.
 REQUIRED OFF-STREET PARKING SPACES SHALL BE DELINEATED
 BY FOUR INCH WHITE DOUBLE STRIPED LINES. CURBS,
 WHEEL-STOPS, OR BOLLARDS SHALL BE INSTALLED TO PROTECT
 LANDSCAPED AREAS, PEDESTRIAN AREA, BUILDINGS, AND
 PROPERTY LINES. ALL SIGNS SHALL COMPLY WITH THE MANUAL
 OF UNIFORM TRAFFIC CONTROL DEVICES FEDERAL HIGHWAY
 ADMINISTRATION, UNITED STATES DEPARTMENT OF
 TRANSPORTATION, 1978, AS ADOPTED BY THE STATE
 DEPARTMENT OF TRANSPORTATION, AS REVISED.
  
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2020-12-17 Cont ID  
Sent By kalexand Date 2020-12-17 Time 10:00 Rev Time 0.00
Received By kalexand Date 2020-12-17 Time 10:00 Sent To I
Notes
2020-12-17 10:38:34ZONING PLAN REVIEW
 ________________________________________
  
 DATE OF REVIEW:
 ________________________________________
  
 REVIEW STATUS: FAILED
 ________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. INADEQUATE INFORMATION PROVIDED. PLEASE PROVIDE THE
 FOLLOWING INFORMATION:
 -- STRIPING DETAILS PER CITY GUIDELINES PROVIDED IN
 ZLDR SEC. 94-485(G).
 -- STALL DIMENSIONS PURSUANT TO ZLDR SEC. 94-485. NOTE:
 MINIMUM WIDTH FOR REGULAR STALL IS 8'6", FOR ACCESSIBLE
 STALLS 12'0"
 -- PROVIDE TOTAL PARKING CALCULATIONS INCLUDING TOTAL
 NUMBER OF ACCESSIBLE PARKING SPOTS
 ________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 IF YOU SUBMITTED A PAPER APPLICATION, AND YOU WOULD
 LIKE TO RESUBMIT ELECTRONICALLY, EMAIL
 [email protected] AND REQUEST TO HAVE YOUR
 PROJECT CONVERTED TO PROJECTDOX. YOU WILL RECEIVE LOG
 IN INFORMATION AND A LINK TO UPLOAD YOUR RESUBMITTAL.
 PLEASE BE SURE TO ?COMPLETE THE UPLOAD TASK? WHEN YOU
 ARE FINISHED UPLOADING.
 ________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 KIZZI ALEXANDRE, ASSOCIATE PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION